JA
Dometic logo
公式取扱説明書

Dometic Compressor Refrigerator (10-Series)

244 ページ·1.6 MB·冷蔵庫·PDF·EN
Dometic Compressor Refrigerator (10-Series)
目次 10セクション 1 Explanation of symbols · 2 Safety instructions · 2.1 General safety · 2.2 Operating the device safely · … 表示非表示
Page 1 of the Dometic Compressor Refrigerator (10-Series) user manual — NO
1ページ · クリックして拡大
1ページ

REFRIGERATION

10-SERIES

Dometic Compressor Refrigerator (10-Series) — REFRIGERATION diagram (page 1)
図 1

RC10.4(S)(T).70, RC10.4(S)(T).90, RC10.4P.100 RCS10.5(X)(S)(T), RCL10.4(S)(T), RCD10.5(X)(S)(T)

Compressor refrigerator Installation Manual 8

Absorptiojääkaappi Asennusohje 138

FI

Kompressor-Kühlschrank Montageanleitung 21

Абсорбционный холодильник Инструкция по монтажу 151

DE

RU

Réfrigérateur à compression Instructions de montage 34

Lodówka absorpcyjna Instrukcja montażu 165

FR

PL

Nevera con extractor Instrucciones de montaje 47

Absorpčná chladnička Návod na montáž 178

ES

SK

Frigorífico de absorção Instruções de montagem 60

Absorpční lednička Návod k montáži 191

PT

CS

Frigorifero ad assorbimento Indicazioni di montaggio 73

Abszorberes hűtőszekrény Szerelési útmutató 204

IT

HU

Compressorkoelkast Montagehandleiding 86

Absorpcijski hladilnik Navodilo za montažo 217

NL

SL

Absorber-køleskab Monteringsvejledning 99

Ψυγείο υγραερίου/ρεύματος Οδηγίες τοποθέτησης 230

DA

EL

Absorptionskylskåp Monteringsanvisning 112

SV

Absorbsjons-kjøleskap Monteringsanvisning 125

NO

Page 2 of the Dometic Compressor Refrigerator (10-Series) user manual
2ページ · クリックして拡大
2ページ

© 2021 Dometic Group. The visual appearance of the contents of this manual is protected by copyright and design law. The underlying technical design and the products contained herein may be protected by design, patent or be patent pending. The trademarks mentioned in this manual belong to Dometic Sweden AB. All rights are reserved.

Page 3 of the Dometic Compressor Refrigerator (10-Series) user manual
3ページ · クリックして拡大
3ページ
Dometic Compressor Refrigerator (10-Series) diagram (page 3)
図 2

RC(S)(L)(D)10-Series

Page 4 of the Dometic Compressor Refrigerator (10-Series) user manual
4ページ · クリックして拡大
4ページ
Dometic Compressor Refrigerator (10-Series) diagram (page 4)
図 3

RC(S)(L)(D)10-Series

Page 5 of the Dometic Compressor Refrigerator (10-Series) user manual
5ページ · クリックして拡大
5ページ
Dometic Compressor Refrigerator (10-Series) diagram (page 5)
図 4

Ø 0,75 mm² 6 m = Ø 10 mm²

RC(S)(L)(D)10-Series

Page 6 of the Dometic Compressor Refrigerator (10-Series) user manual
6ページ · クリックして拡大
6ページ
Dometic Compressor Refrigerator (10-Series) diagram (page 6)
図 5

RC(S)(L)(D)10-Series

Page 7 of the Dometic Compressor Refrigerator (10-Series) user manual
7ページ · クリックして拡大
7ページ
Dometic Compressor Refrigerator (10-Series) diagram (page 7)
図 6
Page 8 of the Dometic Compressor Refrigerator (10-Series) user manual — 1 Explanation of symbols ! ! A I
8ページ · クリックして拡大
8ページ

Explanation of symbols RC(S)(L)(D)10-Series

Please read these instructions carefully and follow all instructions, guidelines, and warnings included in this product manual in order to ensure that you install, use, and maintain the product properly at all times. These instructions MUST stay with this product. By using the product, you hereby confirm that you have read all instructions, guidelines, and warnings carefully and that you understand and agree to abide by the terms and conditions as set forth herein. You agree to use this product only for the intended purpose and application and in accordance with the instructions, guidelines, and warnings as set forth in this product manual as well as in accordance with all appli- cable laws and regulations. A failure to read and follow the instructions and warnings set forth herein may result in an injury to yourself and others, damage to your product or damage to other property in the vicinity. This product manual, including the instructions, guidelines, and warnings, and related documentation, may be subject to changes and updates. For up-to-date product information, please visit dometic.com.

Table of contents

1 Explanation of symbols 8

2 Safety instructions 9

3 Installing the refrigerator 13

4 Technical data 17

1 Explanation of symbols ! ! A I

Page 9 of the Dometic Compressor Refrigerator (10-Series) user manual — 2.1 General safety !
9ページ · クリックして拡大
9ページ

2 Safety instructions

This product is only suitable for the intended purpose and application in accordance with these instructions.

This manual provides information that is necessary for proper installation and/or operation of the product. Poor installation and/or improper operating or mainte- nance will result in unsatisfactory performance and a possible failure.

The manufacturer accepts no liability for any injury or damage to the product resulting from:

  • Incorrect assembly or connection, including excess voltage
  • Incorrect maintenance or use of spare parts other than original spare parts provided by the manufacturer
  • Alterations to the product without express permission from the manufacturer
  • Use for purposes other than those described in this manual

Dometic reserves the right to change product appearance and product specifications.

2.1 General safety !

  • Ensure that the device has been installed by a qualified technician in accordance with the Dometic installation manual.
  • Do not operate the device if it is visibly damaged.
  • If this device's power cable is damaged, it must be replaced by the manufacturer, a service agent or a similarly qualified person in order to prevent safety hazards.
  • This device may only be repaired by qualified personnel. Inadequate repairs may cause serious hazards.
  • Do not store any explosive substances, such as spray cans with propellants, in the device.

RC(S)(L)(D)10-Series Safety instructions · Electrocution hazard · Explosion hazard

Page 10 of the Dometic Compressor Refrigerator (10-Series) user manual — 2 Safety instructions
10ページ · クリックして拡大
10ページ
  • This device can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the device in a safe way and understand the hazards involved.
  • Children shall not play with the device.
  • Cleaning and user maintenance shall not be made by children without supervision.
  • Children aged from 3 to 8 years are allowed to load and unload refrigerating devices.

Risk of child entrapment

  • Make sure that the shelves are mounted and secured so that children cannot lock themselves in the device.
  • Before disposing of your old refrigerator: – Dismantle the drawers. – Leave the shelves in the refrigerator so that children cannot climb inside. !
  • Do not put your fingers into the hinge.
  • Foodstuff may only be stored in its original packaging or in suitable containers. A
  • Check that the voltage specification on the type plate is the same as that of the power supply.
  • If your vehicle does not have a battery undervoltage cutout, disconnect the device or switch it off when you turn off the engine. Otherwise you may discharge the battery.
  • The device is not suitable for storing substances which are caustic or contain solvents.
  • Keep the drainage outlet clean at all times.
  • Do not open the refrigerant circuit under any circumstances.
Show 4 more labels / short text on this page
Safety instructions RC(S)(L)(D)10-Series · Health hazard · Risk of crushing · Health hazard
Page 11 of the Dometic Compressor Refrigerator (10-Series) user manual — 2.2 Operating the device safely D
11ページ · クリックして拡大
11ページ
  • Do not transport the device in a horizontal position, so that no oil can leak out of the compressor and through this damage the refrigerant circuit.
  • Make sure that the refrigerant circuit is not damaged during transportation. The refrigerant in the refrigerant circuit is highly flammable. In the event of any damage to the refrigerant circuit: – Avoid naked flames and sparks. – Air the room well.
  • Set up the device in a dry location where it is protected against splashing water.

2.2 Operating the device safely D

  • Do not touch exposed cables with your bare hands. !
  • Before starting the device, ensure that the power supply line and the plug are dry.
  • Make sure that you only put items in the device which may be chilled at the selected temperature.
  • Food may only be stored in its original packaging or in suitable containers.
  • Opening the door for long periods can cause significant increase of the temperature in the compartments of the device.
  • Clean regularly surfaces that can come in contact with food and accessible drainage systems.
  • Store raw meat and fish in suitable containers in the device, so that it is not in contact with or can drip onto other food.
Show 4 more labels / short text on this page
RC(S)(L)(D)10-Series Safety instructions · Electrocution hazard · Electrocution hazard · Health hazard
Page 12 of the Dometic Compressor Refrigerator (10-Series) user manual — NOTE
12ページ · クリックして拡大
12ページ
  • If the device is left empty for long periods: – Switch off the device. – Defrost the device. – Clean and dry the device. – Leave the door open to prevent mould developing within the device.
  • If the refrigerator is exposed to a room temperature of below +10 °C for an extended period of time, a uniform temperature cannot be guaranteed in the freezer compartment. This can lead to an increase of the freezer compartment temperature and the goods stored in it may defrost.
  • The device door or the freezer door can completely detach from the device if used incorrectly. Push the doors closed until you hear a clear click at the top and bottom.
  • Do not lean on the open device door. A
  • If the door is not locked correctly on the opposite side, push on that side at the top and the bottom until it locks in place.
  • Only store heavy objects such as bottles or cans in the device door, in the vegetable compartment or on the bottom shelf.
  • Do not use electrical devices inside the cooling device unless they are recommended by the manufacturer for that purpose.
  • Do not place it near naked flames or other heat sources (heaters, direct sunlight, gas ovens etc.).
  • Ensure that the ventilation vents are not covered.
  • Do not fill the inner container with ice or fluid.
  • Never immerse the device in water.
  • Protect the device and the cable against heat and moisture.
  • Make sure that foodstuffs do not touch the walls of the cooling area. I

NOTE

  • Ask your vehicle manufacturer if the battery management of your vehicle shuts down the devices to protect the battery.
  • Put the device door and the freezer door into the winter position if you are not going to use the device for a longer period of time. This prevents mold from forming.

Safety instructions RC(S)(L)(D)10-Series · Risk of injury

Page 13 of the Dometic Compressor Refrigerator (10-Series) user manual — 3.1 Preparing the installation ! A
13ページ · クリックして拡大
13ページ

RC(S)(L)(D)10-Series Installing the refrigerator

  • For ambient temperatures of +15 °C to +25 °C, select the average temperature setting.

3 Installing the refrigerator !

You find the instructions for changing the door stop and the decorative plate online at:

documents.dometic.com/?object_id=63258

The device is suitable for installation in:

  • caravans
  • motor homes

3.1 Preparing the installation ! A

  • NOTICE! Damage hazard
  • The refrigerator may not be installed in the rear of mobile homes with the door pointing in the direction of travel.
  • Leave the device in a vertical position for at least 3 hours before starting up for the first time.
  • NOTE
  • In Camper Vans an undercounter unit can be installed with the door pointing in the direction of travel, as long as it is installed next to the sliding door and behind the co-driver’s seat.
  • If the compressor fridge replaces an absoption unit, you have to make sure, that the external ventilation grills are completely closed, otherwise there is the risk, that the compressor will not run at low ambient temperature (~below 0 °C).
Page 14 of the Dometic Compressor Refrigerator (10-Series) user manual — RC10.4(S)(T).70 RC10.4(S)(T).90 RC10.4P.100
14ページ · クリックして拡大
14ページ

Installing the refrigerator RC(S)(L)(D)10-Series

When installing the refrigerator, note the following:

  • Ensure that the floor is solid and level. Park the vehicle horizontally for this purpose.
  • The refrigerator must be installed so that – it is easily accessible for service work – easy to de-install and install – can be easily removed from the vehicle
  • The refrigerator must be installed in a recess so that it stands secure when the vehicle is in motion. Note the dimensions in fig. 1 , page 3 and fig. 2 , page 4 for this purpose.
  • Also note the following recess dimension (fig. 3 , page 5):

RC10.4(S)(T).70 RC10.4(S)(T).90 RC10.4P.100

Refrigerator height (A) 821 mm 975 mm 900 mm

Refrigerator width (B) 420 mm 420 mm 420 mm (rear compressor)

590 mm (side compressor)

Refrigerator depth (C) (excludes control knob 5 mm)

450 mm 485 mm 655 mm (rear compressor)

485 mm (side compressor)

Recess height (H) 823 mm 977 mm 902 mm

Recess width (W) 425 mm 425 mm 425 mm (rear compressor)

595 mm (side compressor)

Recess depth (D) 452 mm 487 mm 657 mm (rear compressor)

487 mm (side compressor)

Page 15 of the Dometic Compressor Refrigerator (10-Series) user manual — 3.2 Installing the condensation drain I
15ページ · クリックして拡大
15ページ

RC(S)(L)(D)10-Series Installing the refrigerator

RCL10.4(S)(T) RCD10.5(S)(T) RCD10.5X(S)(T)

Refrigerator height (A) 1293 mm 1282 mm 1282 mm

Refrigerator width (B) 420 mm 523 mm 523 mm

Refrigerator depth (C) (excludes control knob 5 mm)

595 mm 565 mm 620 mm

Recess height (H) 1296 mm 1285 mm 1285 mm

Recess width (W) 425 mm 528 mm 528 mm

Recess depth (D) 598 mm 568 mm 623 mm

RCS10.5(S)(T) RCS10.5X(S)(T)

Refrigerator height (A) 821 mm 821 mm

Refrigerator width (B) 523 mm 523 mm

Refrigerator depth (C) (excludes control knob 5 mm)

555 mm 610 mm

Recess height (H) 824 mm 824 mm

Recess width (W) 528 mm 528 mm

Recess depth (D) 558 mm 613 mm

3.2 Installing the condensation drain I

  • NOTE
  • Condensation can form inside the refrigerator due to frequent door opening, incorrectly stored food or food that is stored when it is too warm.
  • Condensation must be drained with a constant slope.

Install the condensation drain as follows:

➤Run the condensation hose from the refrigerator through an opening in the floor

which goes outside.

Page 16 of the Dometic Compressor Refrigerator (10-Series) user manual — !
16ページ · クリックして拡大
16ページ

Installing the refrigerator RC(S)(L)(D)10-Series

3.3 Connecting the power supply A

  • NOTICE!
  • The electrical installation and repairs may only be performed by a specialist in accordance with the applicable national regulations and standards.
  • To avoid voltage loss and therefore a drop in performance, the cable should be kept as short as possible and should not be interrupted if possible. For this reason avoid additional switches, plugs or power strips.
  • Before connecting check whether the operating voltage and the battery voltage correspond (see type plate).

➤Determine the required cross section of the cable in relation to the cable length

according to fig. 4, page 5.

➤Connect the cables to the AMP connector of the refrigerator (fig. 5, page 6).

➤Connect the other ends of the cables to the 12 Vg power supply: A

  • NOTICE!
  • Make sure the polarity is correct.
  • Fit the positive (+) cable with a 10 A fuse.

– as directly as possible – rd (red): with a fuse protection (10 A) fitted to the positive (+) pole – bk (black): to the negative (–) pole

3.4 Securing the refrigerator !

  • WARNING! Fire Hazard
  • When positioning the device, ensure the supply cord is not trapped or damaged.
  • Do not locate multiple portable socket-outlets or portable power supplies at the rear of the device.

!

Page 17 of the Dometic Compressor Refrigerator (10-Series) user manual — 4 Technical data
17ページ · クリックして拡大
17ページ
  • NOTE
  • Attach the side walls or the attached strips so that the screws are tight, even under increased loads (while driving).
  • The refrigerator is designed to provide a regulated air flow. The manufacturer does not recommend to leave additional space between the refrigerator and the recess walls.

➤Move the refrigerator into its final location with the front flange sitting tight

against the recess front.

➤Fasten the screws (fig. 6, page 6) through the plastic bushings in the sides of

the refrigerator, and further into the wall.

➤Put the caps onto the screw heads.

Installing the control panel of RC10.4P.100

➤Install the control panel as shown (fig. 7, page 7).

4 Technical data

For the current EU declaration of conformity for your device please refer to the respective product page on dometic.com or contact the manufacturer directly (see dometic.com/dealer).

This device complies with UN ECE Regulation R10.

This product contains fluorinated greenhouse gases.

The cooling unit is hermetically sealed.

RC(S)(L)(D)10-Series Technical data

Page 18 of the Dometic Compressor Refrigerator (10-Series) user manual — RC10.4(S)(T).70 RC10.4(S)(T).90 RC10.4P.100
18ページ · クリックして拡大
18ページ

RC10.4(S)(T).70 RC10.4(S)(T).90 RC10.4P.100

Gross capacityRefrigerator compartment: Freezer compartment: Total net capacity:

62 l 54.5 l 7.5 l 62 l

86 l 75.5 l 7.5 l 83 l

94 l 81 l 9 l 90 l

Gross capacityNet capacity:

69 l 64 l

90 l 85 l

98 l 93 l

Connection voltage12 V g 12 V g 12 V g
Average power input42 W 45 W 48 W

0.45 kWh/24 h

0.45 kWh/24 h

0.46 kWh/24 h

PERFORMANCE mode:

37.5 Ah/24 h

37.5 Ah/24 h

Climate classT T T
CoolantR134a/40 g R134a/43 g R134a/47 g
CO2 equivalent0.057 t 0.061 t 0.065 t
Global warming potential (GWP)1430 1430 1430
PERFORMANCE modeQUIET mode:

42 dB(A) 39 dB(A) 42 dB(A) 39 dB(A) 42 dB(A) 39 dB(A)

Dimensions H x W x D (in mm): 821 x 420 x 450 975 x 420 x 485 902 x 420 x 655

902 x 590 x 485

Weight19.5 kg 21.4 kg 21 kg

Inspection/certification:

Show 8 more labels / short text on this page
Technical data RC(S)(L)(D)10-Series · Capacity · Excluding freezer compartment · Energy consumption · 38 Ah/24 h · Noise emission (EN60704) · (rear compressor) · (side compressor)
Page 19 of the Dometic Compressor Refrigerator (10-Series) user manual — RCL10.4(S)(T) RCD10.5(S)(T) RCD10.5X(S)(T)
19ページ · クリックして拡大
19ページ

RCL10.4(S)(T) RCD10.5(S)(T) RCD10.5X(S)(T)

Gross capacityRefrigerator compartment: Freezer compartment: Total net capacity:

133 l 116 l 12 l 128 l

153 l 118 l 29 l 147 l

177 l 142 l 35 l 171 l

Gross capacityNet capacity:

139 l 134 l

Connection voltage12 V g 12 V g 12 V g
Average power input54 W 54 W 54 W

0.61 kWh/24 h

0.70 kWh/24 h

0.72 kWh/24 h

PERFORMANCE mode:

Climate classST ST ST
CoolantR134a / 40 g R134a/44 g R134a/44 g
CO2 equivalent0.057 t 0.057 t 0.057 t
Global warming potential (GWP)1430 1430 1430
PERFORMANCE modeQUIET mode:

42 dB(A) 39 dB(A) 42 dB(A) 39 dB(A) 42 dB(A) 39 dB(A)

Dimensions H x W x D (in mm): 1293 x 420 x 595 1282 x 523 x 565 1282 x 523 x 620

Weight32 kg 36.5 kg 39.5 kg

Inspection/certification:

Show 8 more labels / short text on this page
RC(S)(L)(D)10-Series Technical data · Capacity · Excluding freezer compartment · Energy consumption · 51 Ah/24 h · 58 Ah/24 h · 60 Ah/24 h · Noise emission (EN60704)
Page 20 of the Dometic Compressor Refrigerator (10-Series) user manual — RCS10.5(S)(T) RCS10.5X(S)(T)
20ページ · クリックして拡大
20ページ

RCS10.5(S)(T) RCS10.5X(S)(T)

Gross capacityRefrigerator compartment: Freezer compartment: Total net capacity:

78 l 69.1 l 9.2 l 78 l

92 l 80.3 l 12.1 l 92 l

Gross capacityNet capacity:

83 l 83 l

98 l 98 l

Connection voltage12 V 12 V
Average power input5.9 A 5.5 A

0.42 kWh/24 h

0.43 kWh/24 h

PERFORMANCE mode:

35.5 Ah/24 h

Climate classN, ST N, ST
CoolantR600a / 24 g R600a / 23 g
CO2 equivalent0.000072 t 0.000069 t
Global warming potential (GWP)3 3

With air channel:

PERFORMANCE modeQUIET mode:

44 dB(A) 39 dB(A)

44 dB(A) 39 dB(A)

Without air channel:

PERFORMANCE modeQUIET mode:

42 dB(A) 38 dB(A)

42 dB(A) 38 dB(A)

Dimensions H x W x D (in mm): 821 x 523 x 555 821 x 523 x 610

Weight24.5 kg 25 kg

Inspection/certification:

Show 6 more labels / short text on this page
Technical data RC(S)(L)(D)10-Series · Capacity · Excluding freezer compartment · Energy consumption · 35 Ah/24 h · Noise emission (EN60704)
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Dometic Compressor Refrigerator (10-Series)について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Dometic Compressor Refrigerator (10-Series)に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Dometic Compressor Refrigerator (10-Series) 取扱説明書(PDF)

244 ページ·1.6 MB·冷蔵庫·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…