JA
ProPlex logo
公式取扱説明書

ProPlex FloppyDrive Digital DIN Rail Mount

8 ページ·201 KB·マウント·PDF·EN
ProPlex FloppyDrive Digital DIN Rail Mount
目次 4セクション ProPlex FloppyDrive Digital DIN Rail · Quick Start Guide · Setup · Connection Scheme for FloppyFlex Digital 表示非表示
Page 1 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — ProPlex FloppyDrive Digital DIN Rail
1ページ · クリックして拡大
1ページ
ProPlex FloppyDrive Digital DIN Rail Mount — ProPlex FloppyDrive Digital DIN Rail diagram (page 1)
図 1 · ProPlex FloppyDrive Digital DIN Rail

D A T A D I S T R I B U T I O N

ProPlex FloppyDrive Digital DIN Rail Mount — ProPlex FloppyDrive Digital DIN Rail diagram (page 1)
図 2 · ProPlex FloppyDrive Digital DIN Rail

ProPlex FloppyDrive Digital DIN Rail

Quick Start Guide

Page 2 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — Setup
2ページ · クリックして拡大
2ページ

Setup

ProPlex DIN Rail devices use a standard Phoenix MSTB screw terminal connector in various pin configurations. Please refer to the wiring diagrams below for correct hook up of your ProPlex DIN Rail product.

ProPlex FloppyDrive Digital DIN Rail Mount — Setup diagram (page 2)
図 3 · Setup

The ProPlex FloppyDrive Digital DIN Rail must operate at 24 VDC. It can drive a maximum of 15m of 12W per meter Firefly FloppyFlex Digital LED neon and can control a maximum of 120 pixels of RGB.

Addressing and mode selection is done via RDM protocol.

1. Connect the DC power (24V) to the power input located in the left top corner. The connector should be wired as follows:
ProPlex FloppyDrive Digital DIN Rail Mount — Setup diagram (page 2)
図 4 · Setup
Page 3 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — Setup
3ページ · クリックして拡大
3ページ
2. Connect the DMX signal input to the DMX input located in the right top corner of the unit. The connector should be wired as follows:
ProPlex FloppyDrive Digital DIN Rail Mount — Setup diagram (page 3)
図 5 · Setup

2.1 To pass DMX to another device, connect the DMX cable to the DMX Thru port located in the right top corner of the unit. The connector should be wired as follows:

ProPlex FloppyDrive Digital DIN Rail Mount — Setup diagram (page 3)
図 6 · Setup
3. Connect the FloppyFlex Digital to the output connector of the FloppyDrive Digital DIN Rail.

The connectors should be wired as follows:

ProPlex FloppyDrive Digital DIN Rail Mount — Setup diagram (page 3)
図 7 · Setup
Page 4 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — Connection Scheme for FloppyFlex Digital
4ページ · クリックして拡大
4ページ

Connection Scheme for FloppyFlex Digital

ProPlex FloppyDrive Digital DIN Rail Mount — Connection Scheme for FloppyFlex Digital diagram (page 4)
図 8 · Connection Scheme for FloppyFlex Digital
Page 5 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — Connection scheme for DMX Thru-Port usage
5ページ · クリックして拡大
5ページ

Connection scheme for DMX Thru-Port usage

ProPlex FloppyDrive Digital DIN Rail Mount — Connection scheme for DMX Thru-Port usage diagram (page 5)
図 9 · Connection scheme for DMX Thru-Port usage
Page 6 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — Dimensions and Connections
6ページ · クリックして拡大
6ページ

Dimensions and Connections

ProPlex FloppyDrive Digital DIN Rail Mount — Dimensions and Connections diagram (page 6)
図 10 · Dimensions and Connections
ProPlex FloppyDrive Digital DIN Rail Mount — Dimensions and Connections diagram (page 6)
図 11 · Dimensions and Connections
Page 7 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — LED Status Information
7ページ · クリックして拡大
7ページ

LED Status Information

ProPlex FloppyDrive Digital DIN Rail Mount — LED Status Information diagram (page 7)
図 12 · LED Status Information

The Power LED has two states: ON and OFF.

  • ON: Unit is receiving power
  • OFF: Unit is not receiving power

The DMX input activity LED has two states: OFF and BLINKING YELLOW.

  • OFF: There is no active incoming DMX signal.
  • BLINKING YELLOW: There is an active incoming DMX signal. DMX values for FloppyFlex Digital output
ProPlex FloppyDrive Digital DIN Rail Mount — LED Status Information diagram (page 7)
図 13 · LED Status Information
ChannelValueFunctionPixel numb. 1000 ↔ 255RED intensity 0% - 100%1 2000 ↔ 255GREEN intensity 0% - 100%1 3000 ↔ 255BLUE intensity 0% - 100%1 4000 ↔ 255RED intensity 0% - 100%2 5000 ↔ 255GREEN intensity 0% - 100%2 6000 ↔ 255BLUE intensity 0% - 100%2 ………… ………… ………… 358000 ↔ 255RED intensity 0% - 100%120 359000 ↔ 255GREEN intensity 0% - 100%120 360000 ↔ 255BLUE intensity 0% - 100%120
Page 8 of the ProPlex FloppyDrive Digital DIN Rail Mount user manual — LOS ANGELES +1 818.899.8818
8ページ · クリックして拡大
8ページ

CONTACT INFORMATION

LOS ANGELES HEADQUARTERS

527 Park Avenue | San Fernando, CA 91340, USA

Tel+1 818.899.8818 | Fax: +1 818.899.8813

sales@tmb.com

TMB 24/7 TECH SUPPORT

US/Canada+1.818.794.1286
Toll Free1.877.862.3833 (1.877.TMB.DUDE)

UK: +44 (0)20.8574.9739

Toll Free0800.652.5418

techsupport@tmb.com

LOS ANGELES +1 818.899.8818

LONDON +44 (0)20.8574.9700

NEW YORK +1 201.896.8600

BEIJING +86 10.8492.1587

CANADA +1 519.538.0888

ProPlex FloppyDrive Digital DIN Rail Mount — LOS ANGELES +1 818.899.8818 diagram (page 8)
図 14

A full service company providing technical

support, customer service, and follow-up. Providing products and services for the industrial,

entertainment, installation, defense, broadcast, research, telecommunications, and signage industries.

Servicing the global market from offices in Los Angeles, London, New York, Toronto, and Beijing.

ProPlex FloppyDrive Digital DIN Rail Mountについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
ProPlex FloppyDrive Digital DIN Rail Mountに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

ProPlex FloppyDrive Digital DIN Rail Mount 取扱説明書(PDF)

8 ページ·201 KB·マウント·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…