CCTV INDOOR SCANNER CCTV INDOOR SCANNER SCANNER CCTV POUR USAGE À L’INTÉRIEUR ESCÁNER CCTV PARA INTERIORES CCTV SCANNER FÜR DEN INNENBEREICH
図 2図 3
USER MANUAL GEBRUIKERSHANDLEIDING NOTICE D’EMPLOI MANUAL DEL USUARIO BEDIENUNGSANLEITUNG
2ページ · クリックして拡大
2ページ
3ページ · クリックして拡大
3ページ
VIS1 – CCTV INDOOR SCANNER 1. Introduction To all residents of the European Union Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules. If in doubt, contact your local waste disposal authorities. As safety, security and usage requirements vary according to the country or area of buy, please contact your local authorities for an installation and use complying with local requirements. Thank you for buying a Velleman product! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, don't install or use it and contact your dealer. 2. Installation
General The table lists the correct cable connections.
Mounting the Scanner This scanner is designed to operate indoors only and can support a max. load of 15.41lbs (=7kg). In order to perform adequately, the device should be securely fastened to a suitable mounting surface. The camera should be correctly mounted and balanced on the scanner. The round-based scanner is installed directly on the mounting bracket. Tighten the scanner's mounting screws just enough so that the base is effectively immobilised. CAUTION : Do not attach the unit to a drywall. Attach the scanner to the mounting bracket using a hex-head
Normal MountingInverted Mounting
NumberConnectionColourConnectionColour
124VACRED24VACRED
2LEFTWHITERIGHTGREEN or YELLOW
3RIGHTGREEN or YELLOWLEFTWHITE
4COMMONBLACKCOMMONBLACK
図 4
4ページ · クリックして拡大
4ページ
Connecting the Scanner to the Central Unit The power cable of the scanner can be connected to the connections at the back of the central unit (the scanner uses a 24VAC power supply) for independent and automatic operation. Connect the cores of the cable as shown in the table (see above).
Installing the Limit Stops The toothed wheel is slotted at intervals of 5°. The coiled (extension) cord with BNC connector is connected to the rear of the scanner. The reversing switch activator (1 in fig. 1 at the back of the manual) is visible between the toothed wheel and the housing on the front side of the unit. Located on the toothed wheel are two adjustable plastic limit stops (2 and 3 in fig. 1). Both limit stops can be removed, enabling the scanner to rotate 360°. Perform steps 1 through 5 outlined in " Manual Operation of the Scanner " (see below) to establish approximate limit stop settings before mounting the camera. At least 1 of the limit stops should be installed or the scanner will continue its turning motion. Make sure that the camera covers the required detection area and that the rear of the scanner faces away from the area to be covered.
Manual Operation of the Scanner 1. Connect the central unit to a standard 220V-outlet, activate the device and put the "MANUAL/AUTO"-switch in the "MANUAL"-position. 2. Hold the 'LEFT/RIGHT" toggle switch in the "RIGHT"-position until the scanner has reached the desired righthand position. 3. Install the first limit stop (2 in fig. 1) just to the right of the switch actuator (1 in fig. 1) by snapping it in place. 4. Put the "MANUAL/AUTO"-switch in the "MANUAL"-position and hold the "LEFT/RIGHT"-toggle switch in the "LEFT"-position. 5. Install the second limit stop (3 in fig. 1) to the left of the switch actuator (see step 3). 6. Mount the camera on the scanner. Read " Mounting the Camera " (see below). 7. Have the camera pan to both limits (left and right) to verify the position of the limit stops.
Automatic Operation of the Scanner 1. Connect the power cable to the AC outlet. 2. Put the "AUTO/MANUAL"-switch in the "AUTO"-position, allow the unit to autopan to the desired right-hand position and then unplug the cable. 3. Install the first limit stop (2 in fig. 1) just to the right of the switch actuator (1 in fig. 1) by snapping it in place. 4. Plug in the power cable and allow the unit to pan to the desired left-hand position. Unplug the cable. 5. Install the second limit stop (3 in fig. 1) to the left of the switch actuator (see step 3). 6. Mount the camera on the scanner. Read " Mounting the Camera " (see below). 7. Activate the scanner and check the position of both limit stops.
Mounting the Camera Do not use an auto-iris lens with this unit. This would cause the iris mechanism to wear very quickly, as an auto-iris lens constantly compensates for the varying light level. Use a screw with a locknut to mount the camera. Place this screw in one of three positions (see 5 in fig. 1) in order to obtain the best possible balance. The scanner has an off-centre pivot which allows the camera to tilt from 10 degrees below horizon level to 90 degrees above or vice versa, depending on how the camera is mounted (see figures at the back of the manual). Loosen the hex-head screws (4 in fig. 1) with locknut on the side of the mounting bracket to adjust the angle of the camera. Retighten the two screws firmly when the desired angle has been obtained. For more info concerning this product, please visit our website <a href="http://www.velleman.eu" rel="nofollow noopener" target="_blank">www.velleman.eu</a> The information in this manual is subject to change without prior notice.