User Manual
Model: DTH1620 Model: DTH1620

®

The term “WARNING!” indicates instructions regarding personal safety. If the instructions are not followed the result may be bodily injury or death.
The term “CAUTION!” indicates instructions regarding possible damage to physical equipment. If these instructions are not followed, it may result in damage to the equipment that may not be covered under the warranty.
The term “IMPORTANT!” indicates instructions or information that are vital to the successful completion of the procedure.
The term “NOTE” is used to indicate additional useful information.
The intent of the lightning flash with arrowhead symbol in a triangle is to alert the user to the presence of un-insulated «dangerous» voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans.
The intent of the exclamation point within an equilateral triangle is to alert the user to the presence of important safety, and operating and maintenance instructions in this manual.
WARNING! TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. Elevated Operating Ambient Temperature – If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than room ambient. Consideration should be given to ensure that the maximum operating temperature range -10°C to 50°C (14°F to 122°F ) is not exceeded. Reduced Air Flow – Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with a dry cloth. 7. Do not block any ventilation opening. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat. 9. To reduce the risk of electrical shock, the power cord shall be connected to a mains socket outlet with a protective earthing connection. 10. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 11. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 12. Only use attachments/accessories specified by the manufacturer. 13. Unplug this apparatus during lightning storms or when unused for long periods of time. 14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 15. The appliance coupler, or the AC Mains plug, is the AC mains disconnect device and shall remain readily operable after installation. 16. Adhere to all applicable, local codes. 17. Consult a licensed, professional engineer when any doubt or questions arise regarding a physical equipment installation. 18. Do not use any aerosol spray, cleaner, disinfectant or fumigant on, near or into the apparatus. Clean only with a dry cloth. 19. Do not unplug the unit by pulling on the cord, use the plug. 20. Do not submerge the apparatus in water or liquids. 21. Keep ventilation opening free of dust or other matter.
ii TD-001622-01-A

WARNING! Advanced technology, e.g., the use of modern materials and powerful electronics, requires specially adapted maintenance and repair methods. To avoid a danger of subsequent damage to the apparatus, injuries to persons and/or the creation of additional safety hazards, all maintenance or repair work on the apparatus should be performed only by a QSC authorized service station or an authorized QSC International Distributor. QSC is not responsible for any injury, harm or related damages arising from any failure of the customer, owner or user of the apparatus to facilitate those repairs. In the event of malfunction, contact QSC Customer Support for assistance.
NOTE: NOTE: This equipment has been tested and found to comply with the limits for a Class A or Class B digital device when ferrite clamps are installed on the output cables, pursuant to Part 15 of the FCC Rules. To meet Class A or Class B emission requirements two Ferrite 0431176451 clamps are required to be on the customer-supplied output cables connected to J1 and J5. Place the ferrite clamps as close to connectors J1 and J5 as possible.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Life cycle 10 years / Storage temperature -20 ° C to + 70 ° C / Relative humidity 5 - 85% RH
Service life - 10 years. Storage conditions: temperature from -20 ° C to + 70 ° C, humidity 5% - 85%.
If you wish to discard electronic equipment, please contact your dealer or supplier for further information.
The QSC DTH1620 Series Amplifier is in compliance with “China RoHS” directives. The following chart is provided for product use in China and its territories:
iii TD-001622-01-A


For a copy of the QSC Limited Warranty, visit the QSC website at www.qsc.com
One DTH1620 Amplifier · iv TD-001622-01-A


The Attero Tech by QSC DTH1620 is a 16ch x 20 W Dante/AES67 amplifier designed for themed entertainment and immersive theater applications. It features a ruggedized design and compact form factor that enables cost-effective network audio amplification support for individual rides or attractions. The DTH1620 supports traditional passive speaker drivers as well as haptic transducers for specialized audio applications that require high-channel density at low output power.

9 10 11 12 13 14 15 16 6 5 4 3 2 1 – – – + + + 1 2 3 4 5 6 7 8
N9 N10 N11 N12 N13 N14 N15 N16 N1 N2 N3 N4 N5 N6 N7 N8
— Figure 1 — Connector Panel
Connectors J1 & J5
Headphone audio – from channel 16

Audio Output – J1
Pin Channel + Pin Channel-

1 9 Out+ 9 9 Out-
2 10 Out+ 10 10 Out-
3 11 Out+ 11 11 Out-
4 12 Out+ 12 12 Out-
5 13 Out+ 13 13 Out-
6 14 Out+ 14 14 Out-
7 15 Out+ 15 15 Out-
8 16 Out+ 16 16 Out-
— Table 1 —
Headphone Interface – J2

Refer to Get/Set Headphone Limit on page 8
2 Volume Ground Reference (Potentiometer Low)
3 Volume Reference Voltage (Potentiometer High) 3.3V
6 Volume Select Voltage (Potentiometer Wiper)
Volume is set to minimum when there is no potentiometer connected
— Table 2 —
Input Power Interface – J3

— Table 3 —

Network Interface – J4
2 DATA_A-
3 DATA_B+
4 DATA_C+
5 DATA_C-
6 DATA_B-
8 7 6 5 4 3 2 1
7 DATA_D+
8 DATA_D-
— Table 4 —
Audio Output – J5
Pin Channel + Pin Channel –

1 1 Out+ 9 1 Out-
2 2 Out+ 10 2 Out-
3 3 Out+ 11 3 Out-
4 4 Out+ 12 4 Out-
5 5 Out+ 13 5 Out-
6 6 Out+ 14 6 Out-
7 7 Out+ 15 7 Out-
8 8 Out+ 16 8 Out
— Table 5 —
All wiring requirements for this amplifier are specified by the customer based on their specific use case. The cable requirements listed here would allow the unit to function in most applications.
Connectors J1 and J5


Refer to Figure 2
— Figure 2 —

Refer to Figure 3
The serial number information for the unit is found on a label on the bottom side of the amplifier.
digital equipment, pursuant to Part 15 of the FCC Rules, when
cause harmful interferance, and (2) this device must accept
This device complies with Class A and Class B limits for
installed in accordance with the User Manual. Operation is
— Figure 3 —


169.16 mm 6.660 in 51.46 mm 2.02 in 45.97 mm 1.809 in

4x Ø 0.177 in 4.49 mm

— Figure 4 —

The Axon DTH1620 can be mounted in any orientation with a flat surface that meets the dimensional requirements described under “Dimensions” on page 5, is not exposed to rain, condensing humidity, excessive heat or cold, and is strong enough to hold the amplifier, weighing 2 lb, 6 oz, during the intended operational scenarios and shall not block any ventilation holes. In addition, the mounting location must have enough space to allow cable connections without stressing the connections,
The DTH1620 amplifier draws about 15 W when idle. For operational head room, use 20 W as the idle power. When all channels have equal power, a safe formula for computing the required current capability of the power supply is:
Where:
Is = Required power supply current capability
Pc = Power per channel (maximum of 20 W per channel)
Nc = Number of channels (maximum of 16)
Eff = Efficiency factor = 1.25 (80%)
Pi = Idle power of amplifier (20 W)
Vs = Supply voltage (24 VDC)
Example: We want all 16 channels to be simultaneously 5W capable.
Is = ((5 W * 16 channels * 1.25 efficient factor) + 20W ) / 24V
Is = ((5*16*1.25)+20)/24
If all channels have different power output requirements then simply add the output power for all channels.
Is = ((Sp * Eff ) + Pi ) / Vs
Sp = Sum of Power for all channels i.e. (P1 + P2 + P3 + … P16)
Is = ((Pc*Nc*Eff)+Pi)/Vs · Is = 5A

The DTH1620 uses DHCP by default to obtain an IP address. A static IP addres can be set using the Dante Controller. UDP port 49494 is used for sending the command.
The following commands are available for the DTH1620. Version 1.2

Identify Device ID Mode (0 = off, 1 = on) -
Get Output Mute GOM Channel ID (0, 1 to 16) -
Set Output Mute SOM Channel ID (0, 1 to 16) Mode (0 = unmuted, 1 = muted)
Set Output Master Mute SOMM Mode (0 = unmuted, 1 = muted) -
Get Output Volumes GOV Channel ID (0, 1 to 16) -
Set Output Volumes SOV Channel ID (1 to 16) Gain (-103 to 24)
Set Output Master Volume SOMV Gain (-103 to 24) -
Get Channel Name GCN Channel ID (1 to 16) -
Set Fan SFAN Fan enable (0 or 1) -
— Table 7 — DTH1620 Command Set
Identify Device / Find Unit
The intended use of these commands is to locate a device by flashing the device’s non-fault LED’s. When the Identify Device command is sent, with the mode set to on (ID 1), the non-fault LEDs flash on and off until another Identify Device command is sent with the mode set to off (ID 0), or the device is reset or power cycled.
The Find Unit command flashes the non-fault LEDs for five seconds then automatically turn off.

Identify Device (ON) ID 1 ACK ID 1 Identify Device mode active
Identify Device (OFF) ID 0 ACK ID 0 Identify Device mode inactive
Flash Identify LED for 5 seconds FU ACK FU Find Unit mode activated.
— Table 8 — Identify/Find Unit Syntax Example

Version / Bootloader Version
The VERSION command returns the firmware version of the device. BVERSION will return the version of the bootloader.
Recall firmware version VERSION ACK VERSION 1.0 Firmware version is 1.0
Recall bootloader version BVERSION ACK BVERSION 1.0 Bootloader version is 1.0
— Table 9 — Version Recall Syntax Example
A QUERY command allows the control system to retrieve the temperature sensor data and current Identify state.
Query for device state QUERY ACK QUERY TEMP 21.0 21.3 ID 0 Temperature sensor 1 = 21.0C Temperature sensor 2 = 21.3C ID is off.1
— Table 10 — Query Syntax Example
The DEFAULTS command forces the system to return to factory settings:
Restore factory defaults DEFAULTS ACK DEFAULTS
— Table 11 — Default Settings Syntax Example
“Headphone Interface - J2” on page 2
This set of commands gets and sets the headphone volume limit. Valid settings are -103 dB to 24 dB. The headphone volume is optionally controlled by a 10 kΩ potentiometer connected between pins 2 and 6 of connector J2. This command sets the upper limit of the volume setting and can be used to adjust for the maximum volume for a given style of headset.
Get the headphone volume limit GHPLIMIT ACK GHPLIMIT 0 Headphone is currently limited to 0 dB max.
Set the headphone volume limit SHPLIMIT 1 ACK SHPLIMIT 1 Set Headphone limit to 1 dB.
— Table 12 — Get/Set Headphone Volume Limit Syntax Example
Query · Defaults · Get/Set Headphone Limit

This set of commands gets and sets the output mute status for each output channel (parameter 1 is 1...16) or for all output channels (parameter 1 is 0).

Get mute setting for output channel 14 GOM 14 ACK GOM 14 ON
Unmute output channel 14 SOM 14 0 ACK SOM 14 0
Get mute settings for all output channels GOM 0 ACK GOM 0 0xFFFF
Unmute output channels 1..4, mute output channels 5..16 SOM 0 0xFFF0 ACK SOM 0 0xFFF0
— Table 13 — Get/Set Output Mute Syntax Example
Get/Set Output Master Mute
This set of commands gets and sets the output master mute status. The master mute mutes all channels simultaneously. Clearing Master Mute will only clear the master mute state; it will not clear an individual channel’s mute state.
Get Master Mute setting GOMM ACK GOMM ON
Set Master Mute SOMM 0 ACK SOMM 0
— Table 14 — Get/Set Output Master Mute Syntax Example
This set of commands gets and sets the volumes for each output channel (parameter 1 is 1...16) or for all output channels (parameter 1 is 0) range is +24 dB to -103 dB. The total output volume is a combination of the individual channel and Master volume up to the 20W maximum for the channel.

Get volume setting for output channel 9 GOV 9 ACK GOV 9 -30
Set volume setting for output channel 9 SOV 9 0 ACK SOV 9 0
Get volume settings for all output channels GOV 0 ACK GOV 0 -2 -3 0 … -12
— Table 15 — Get/Set Output Volume Syntax Example
Get/Set Output Master Volume
This set of commands gets and sets the Output Master Volume. Range is +24 dB to -103 dB. The Master volume is applied after the individual channel volume settings. For a direct pass through of channel volumes, the Master Volume should be set to 0 db. The total output volume is a combination of the individual channel and Master volume up to the 20 W maximum for the channel.
Get Master Volume setting GOMV ACK GOMV -3
Set Master volume setting. SOMV 9 0 ACK SOMV -3
— Table 16 — Get/Set Master Output Volume Syntax Example
Get/Set Output Mute · Get/Set Output Volume

The GSTAT command allows the control system to get a snapshot of the settings of the device. The command takes no parameters.
Get current device status GSTAT ACK GSTAT followed by the binary structure below
— Table 17 — Status Syntax Example
Get Status Response Structure
int8_t channelVolumes[16]; // value between -103 - 24
uint8_t channelMutes[16]; // 0 = unmuted, 1 = muted
int8_t masterVolume; // value between -103 - 24
uint8_t masterMute; // 0 = unmuted, 1 = muted
int8_t hpVolumeLimit; // value between -103 - 24
uint8_t fanEnable; // 0 = Off, 1 = On
uint8_t identifyMode; // 0 = Identify Off, 1 = Identify On
uint8_t danteLockState; // 0 = unlocked, 1 = locked
The data shall be placed such that array index 0 is channel 1 for all channel data.
The entire structure is 38 bytes.
This command gets all metering data for all Dante channels. The response contains 64 hexadecimal formatted values.
The metering values are the following:
Values between 0x01 (0 dB) and 0xFD (-126 dB) represent increments of -0.5 dB.
Get metering data GSM ACK GSM 0xFE 0xFE … 0xFD 3
— Table 18 — Get Metering Data Example

This command gets the name of the Dante channel corresponding to a channel.
Valid values are 1–16.
Description of Command Example Command Example Response
Get Channel Name GCN 3 ACK GCN 3 Lobby
— Table 19 — Get Channel Name Syntax Example
This command returns the status of the Dante Device lock.
Description of Command Example Command Example Response
Get Device Lock GDEVICELOCK ACK GDEVICELOCK UNLOCKED
— Table 20 — Get Device Lock Syntax Example
These commands get the Fan Enable status or sets the Fan Enable. If the Fan Enable is active and the Fan does not function then the Fan LED will turn on RED. If the Fan is disabled and the internal temperature reaches 85 Degrees Celsius, the Fan LED will turn RED.
Get Fan setting GFAN ACK GFAN ON
Set Fan setting. SFAN 1 ACK SFAN 1
— Table 21 — Get/Set Fan Enable Syntax Example
Get Channel Name · Get Device Lock · Get/Set Fan

Specification Description Test Result Additional Info
Frequency Response (8 ohm) 1W +0.5dB, -1.5dB
Frequency Response (8 ohm) 20W +0.5dB, -1.5dB
Frequency Response (16 ohm) 1W +1.0dB, -0.5dB
Frequency Response (16 ohm) 10W +1.0dB, -0.5dB
Noise (20Hz - 20KHz) into 8Ω -73dBu
Noise (20Hz - 20KHz) into 16Ω -72dBu
Signal to Noise (20Hz - 20KHz) 20W 8Ω 97dB
Signal to Noise (20Hz - 20KHz) 1W 8Ω 84dB
DBFS for 1W into 8 ohms -18.500dBFS
DBFS for 20W into 8 ohms -5.500dBFS
DBFS for 1W into 16 ohms -15.700dBFS
DBFS for 10W into 16 ohms -5.600dBFS
Output Circuitry Class D
THD+N @ 1W into 8 ohms @ 1KHz
THD+N @ 20W into 8 ohms @ 1KHz
THD+N @ 1W into 16 ohms @ 1KHz
THD+N @ 10W into 16 ohms @ 1KHz
Maximum Digital Input Level 0dBFS
Cooling Fan With Thermal Speed Control
Headphone/Volume Control Molex 6-pin
Ethernet Connector RJ-45 With Link and Activity LED indicators
Top Panel Indicators Power OK, Amps OK, Dante OK Fan Fault
Operating Mode Low Impedance 8 ohm/16 ohm only
Amplifier Control (Network) Control and Status Via the Network, see manual for API details
Amplifier Volume Control (Remote) 10K Linear Potentiometer
Dimensions 9” (229mm) D x 6.66” (169) W x 2.02” (51mm) H
Net Weight 2.4 lbs. (1.1kg)
Shipping Weight 2.842 lbs (1.29 kg)
Power Requirements +24VDC @ 3A, all channels 1/8 power +24VDC @ 17.5A, all channels full power
Carton Contents DTH1620 Amplifier

QSC, LLC
Costa Mesa, CA 92626-1468 U.S.
1.800.854.4079 toll free (U.S. only)
(Monday – Friday 7 AM to 5 PM PST (Excludes Holidays)
Voice +1.714.957.7150 1.800.772.2834 toll free (U.S. only)
Access our Self-Help Portal for additional information, FAQs, and documents. You may also register or login to open a case with QSC Technical Services.
https://qscprod.force.com/selfhelpportal/s/
© 2020 QSC, LLC. All rights reserved. QSC and the QSC logo are registered trademarks of QSC, LLC in the U.S. Patent and
Trademark office and other countries. All other trademarks are the property of their respective owners.
®
この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。
ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。
最初の質問を投稿しましょう。他のユーザーや当チームが回答します。