COOLMATIC

Built-in cooling device with compressor Operating manual 5
Kompressor-Einbaukühlbox Bedienungsanleitung 21
FR
Glacière à compression à encastrer Notice d’utilisation 37
Compressor-inbouwkoelbox Gebruiksaanwijzing 54






0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 0


Explanation of symbols CB, RHD
The manufacturer accepts no liability for damage in the following cases:

CB, RHD Safety instructions

Intended use CB, RHD
The cooling device is suitable for cooling and freezing (only CB36 and CB40) foodstuffs. The device is also suitable for use on boats. !

CB, RHD Scope of delivery
5 Accessory
If you wish to operate the cooling device with a 230 V AC mains supply, please use one of the following rectifiers:
Description Ref. no.
MPS-35, rectifier (110 – 240 V: 24 V) 9600000445
CoolMatic CB36, CB40 and RHD50 cooling devices are suitable for use with a 12 V or 24 V DC voltage and can therefore also be used for camping or on boats. You can also use the EPS-100W and MPS-35 rectifiers to connect them to a 230 V mains supply.
The cooling device can chill products and keep them cool. CoolMatic CB36 and CB40 devices can also be used to freeze products.
All materials used in the cooling device are compatible for use with foodstuffs. The refrigerant circuit is maintenance-free.
You can use the continuously variable thermostat in the interior of the device to set the desired temperature.
The cooling device has a undervoltage protection mechanism. To protect the battery, the cooling device switches off automatically if the voltage is insufficient. When the voltage is sufficient again, it switches on again.
When used on boats the cooling device can be subjected to a constant inclination of 30°.
CoolMatic CB36 and CB40 devices are equipped with a removable cooling unit that can be mounted separately.
Quantity Description · 1 Cooling device · 1 Operating manual

Installing and connecting the cooling device CB, RHD
The device is designed for ambient temperatures between 16 °C and 32 °C. In continuous operation, the air humidity may not exceed 90 %.
Install the cooling device in a dry, sheltered place (installation dimensions: fig. 1 to fig. 3, page 3). Avoid installing the devices next to heat sources such as heaters, gas ovens, hot water pipes, etc.
The cooling device must be installed so that heated air from the cooling unit can dissipate easily. Therefore make sure there is adequate ventilation.
On the CoolMatic CB36, CB40 and RHD50 devices, the cooling unit is removable and can be mounted at a distance of up to 1.5 m (CB36, CB40, RHD50) away from the cooler if space is limited.
The lids of the devices can be adapted to match the decor of the surroundings.
Connecting to a battery
The cooling device can be operated with a 12 V to 24 V DC voltage supply. A

CB, RHD Installing and connecting the cooling device
➤Determine the required cross section of the cable in relation to the cable length
according to fig. 4, page 4.
Key for fig. 4, page 4
Co-ordinate axis Meaning Unit
l Cable length m
Cable cross section mm²
➤Connect the red lead to the positive terminal.
➤Connect the black lead to earth.
➤Before starting up the device for the first time, check whether the operating volt-
age and the battery voltage correspond (see type plate).
➤Connect the cooling device
– As directly as possible to the pole of the battery or – To a plug socket which is fused with at least 15 A (at 12 V) or 7.5 A (at 24 V). A
The cooling device is equipped with an electronic device to protect against reversing the polarity and short circuits when connecting to a battery. To protect the battery, the cooling device switches off automatically if the voltage is insufficient (see table below).
Switch-off voltage 10.4 V 22.8 V
Switch-on voltage 11.7 V 24.2 V

➤To operate the cooler on a 230 V or 110–240 V mains supply, use the EPS-100W
(230 V) or MPS-35 (110 – 240 V) rectifier.
Operation CB, RHD

The cooling device conserves fresh foodstuffs. You can conserve frozen foodstuffs and freeze fresh foodstuffs in the CoolMatic CB36 and CB40 devices. A
➤Switch the cooling device on by turning the knob to the right. I A
RHD50 To open the cooling device, pull the clip (fig. 5 1, page 4) and open the door.
To lock the cooling device, close the door and press it until the lock engages.
CB36/CB40 The lid rests on top and is not locked.
You can set the temperature to any level using the knob. The built-in temperature control regulates the temperature as follows:
CB, RHD Operation · Lock · Setting the temperature

You can conserve foodstuffs in the cooling device compartment. The time for which the food can be conserved in this way is usually stated on the package. A I
The cooling device compartment is divided in different zones with different temperatures:
➤Observe the following when using the device:
Defrosting the cooling device (only CB36, CB40)
Humidity can form frost in the interior of the cooling device or on the vaporiser. This reduces the cooling capacity. Defrost the device in good time to avoid this. A
To defrost the cooling device, proceed as follows:
➤Take out the contents of the cooling device.
➤Place them in another cooling device to keep them cool, if necessary.
➤Set the knob to “0”.
➤Leave the cover open.
Operation CB, RHD · Conserving foodstuffs

CB, RHD Cleaning and maintenance
➤Wipe off the defrosted water.
Switching off and storing the cooling device
If you do not intend to use the cooling device for a long time, proceed as follows:
➤Turn the knob to “0”.
➤Disconnect the power cable from the battery or pull the DC cable plug out of the
rectifier.
➤Clean the cooling device (see chapter “Cleaning and maintenance” on page 15).
➤Leave the lid or door open for to avoid unpleasant odours building up.
➤Occasionally clean the device interior and exterior with a damp cloth.
➤Make sure that the air inlet and outlet vents on the device are free of any dust and
dirt, so that heat can be released and the device is not damaged.
➤Make sure that no water drips into the sealing. This can damage the electronics.
➤Wipe the cooling device dry with a cloth after cleaning.

The statutory warranty period applies. If the product is defective, please contact the manufacturer's branch in your country (see the back of the instruction manual for the addresses) or your retailer.
For repair and guarantee processing, please include the following documents when you send in the device:
➤Place the packaging material in the appropriate recycling waste bins wherever
If you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
Guarantee CB, RHD

Compressor does not run
Fault Possible cause Remedy
UT = 0 V The connection between the battery and the electronics is interrupted
Main switch defective (if installed) Replace the main switch
Additional supply line fuse has blown (if installed)
UT UON Battery voltage is too low Charge the battery
Start attempt with UT UOFF
Loose cables Poor contact (corrosion)
Battery capacity too low Replace the battery
Cable cross section too low Replace the cable (fig. 4, page 4)
Start attempt with UT UON
Ambient temperature too high –
Insufficient ventilation Move the cooling device
Condenser is dirty Clean the condenser
Fan defective (if installed) Replace the fan
UT Voltage between the positive and negative electronic terminals
UON Switch-on voltage of the electronics
UOFF Switch-off voltage of the electronics

Interior temperature too low in control setting “1”
Fault Possible cause Remedy
Thermostat sensor has no contact to the vaporiser
Thermostat defective Change the thermostat
Short circuit in the thermostat line
Compressor runs for a long time
A large amount has frozen solid in the device (only CB36, CB40)
Cooling capacity drops, interior temperature rises
Fault Possible cause Remedy
Compressor runs for a long time/continuously
Vaporiser iced over Defrost the vaporiser
Ambient temperature too high –
Insufficient ventilation Move the cooling device
Condenser is dirty Clean the condenser
Fan defective (if installed) Replace the fan
Battery capacity exhausted Charge the battery
Fault Possible cause Remedy
Loud humming A component of the refrigerant circuit cannot move freely (lies against the wall)
Bend the component carefully
Foreign body jammed between the cooling device and the wall
Remove the foreign body
Fan noise (if installed) –

CB, RHD Technical data
CoolMatic CB36, CB40 and RHD50 cooling devices all have the following features:
Global warming potential (GWP):
Dimensions (WxHxD) in mm (with compressor):
fig. 1, page 3 fig. 2, page 3
Global warming potential (GWP):
Dimensions (WxHxD) in mm (with compressor):
fig. 3, page 3

Technical data CB, RHD
The coolant circuit contains R134a.
Contains fluorinated greenhouse gases
Complies with ErP/EuP directive.
Test/certificates · Hermetically sealed equipment
よくあるトラブル、考えられる原因、対処法。
| 問題 | 考えられる原因 | 対処法 | |
|---|---|---|---|
| U = 0 V T | The connection between the battery and the electronics is interrupted | Establish a connection | p.17 |
| U = 0 V T | Main switch defective (if installed) | Replace the main switch | p.17 |
| U = 0 V T | Additional supply line fuse has blown (if installed) | Replacing the fuse | p.17 |
| U U T ON | Battery voltage is too low | Charge the battery | p.17 |
| Start attempt with U U T OFF | Loose cables Poor contact (corrosion) | Establish a connection | p.17 |
| Start attempt with U U T OFF | Battery capacity too low | Replace the battery | p.17 |
| Start attempt with U U T OFF | Cable cross section too low | Replace the cable (fig. 4, page 4) | p.17 |
| Start attempt with U U T ON | Ambient temperature too high | – | p.17 |
| Start attempt with U U T ON | Insufficient ventilation | Move the cooling device | p.17 |
| Start attempt with U U T ON | Condenser is dirty | Clean the condenser | p.17 |
| Start attempt with U U T ON | Fan defective (if installed) | Replace the fan | p.17 |
| Compressor runs constantly | Thermostat sensor has no contact to the vaporiser | Secure the sensor | p.18 |
| Compressor runs constantly | Thermostat defective | Change the thermostat | p.18 |
| Compressor runs constantly | Short circuit in the thermostat line | p.18 | |
| Compressor runs for a long time | A large amount has frozen solid in the device (only CB36, CB40) | – | p.18 |
| Compressor runs for a long time/continuously | Vaporiser iced over | Defrost the vaporiser | p.18 |
| Compressor runs for a long time/continuously | Ambient temperature too high | – | p.18 |
| Compressor runs for a long time/continuously | Insufficient ventilation | Move the cooling device | p.18 |
| Compressor runs for a long time/continuously | Condenser is dirty | Clean the condenser | p.18 |
| Compressor runs for a long time/continuously | Fan defective (if installed) | Replace the fan | p.18 |
| Compressor runs infrequently | Battery capacity exhausted | Charge the battery | p.18 |
| Loud humming | A component of the refrigerant circuit cannot move freely (lies against the wall) | Bend the component carefully | p.18 |
| Loud humming | Foreign body jammed between the cooling device and the wall | Remove the foreign body | p.18 |
| Loud humming | Fan noise (if installed) | – | p.18 |