JA
Stanley logo
公式取扱説明書

Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504)

44 ページ·2.8 MB·電動工具·PDF·ENDEFRITNL
Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504)
目次 43セクション INSTRUCTION AND · SERVICE MANUAL · ORIGINAL INSTRUCTION · JA 油空圧パワーモジュール · … 表示非表示
Page 1 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — JA 油空圧パワーモジュール
1ページ · クリックして拡大
1ページ

INSTRUCTION AND

SERVICE MANUAL

ORIGINAL INSTRUCTION

Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) — ORIGINAL INSTRUCTION diagram (page 1)
図 1

EN Hydro-Pneumatic Power Module

JA 油空圧パワーモジュール

ZHS 液压气动模块

71504 Module for Blind Rivets Hydro-Pneumatic Power Module

Page 2 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — CONTENT
2ページ · クリックして拡大
2ページ

©2021 STANLEY Black & Decker All rights reserved.

The information provided may not be reproduced and/or made public in any way and through any means (electronically or mechanically) without prior explicit and written permission from STANLEY Engineered Fastening. The information provided is based on the data known at the moment of the introduction of this product. STANLEY Engineered Fastening pursues a policy of continuous product improvement and therefore the products may be subject to change. The information provided is applicable to the product as delivered by STANLEY Engineered Fastening. Therefore, STANLEY Engineered Fastening cannot be held liable for any damage resulting from deviations from the original specifi cations of the product.

The information available has been composed with the utmost care. However, STANLEY Engineered Fastening will not accept any liability with respect to any faults in the information nor for the consequences thereof. STANLEY Engineered Fastening will not accept any liability for damage resulting from activities carried out by third parties. The working names, trade names, registered trademarks, etc. used by STANLEY Engineered Fastening should not be considered as being free, pursuant to the legislation with respect to the protection of trademarks.

CONTENT

1. SAFETY DEFINITIONS 3 1.1 GENERAL SAFETY RULEs 3 1.2 PROJECTILE HARZARDS 3 1.3 OPERATING HAZARDS 4 1.4 REPETITIVE MOTIONS HAZARDS 4 1.5 ACCESSORY HAZARDS 4 1.6 WORKPLACE HAZARDS 4 1.7 NOISE HAZARDS 4 1.8 ADDITIONAL SAFETY INSTRUCTIONS FOR HYDRAULIC POWER TOOLS 5 2. SPECIFICATION 6 2.1 INTENT OF USE 6 2.2 TOOL SPECIFICATION 6 2.3 TOOL DIMENSIONS 6 3. PUTTING IN SERVICE 7 4. OPERATING INSTRUCTIONS 7 5. SERVICING THE TOOL 7 5.1 DAILY SERVICING 7 5.2 WEEKLY SERVICING 7 5.3 ANNUAL SERVICING / EVERY 500K OPERATIONS 7 5.4 SERVICE KIT 7 5.5 HYDRAULIC OIL 8 5.6 DISMANTLING INSTRUCTIONS 8 5.7 PROTECTING THE ENVIRONMENT 8 6. GENERAL ASSEMBLY AND PART LIST 9 6.1 GENERAL ASSEMBLY 9 6.2 PARTS LIST 10 7. SAFETY DATA 10 7.1 HYSPIN VG32 OIL SAFETY DATA 10 7.2 MOLYLITHIUM GREASE EP 3753 - SAFETY DATA 11 7.3 Molykote® 111 GREASE - SAFTEY DATA 11 8. EC DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY 12 9. UK DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY 13 10. PROTECT YOUR INVESTMENT! 14

Page 3 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — 1.2 PROJECTILE HARZARDS
3ページ · クリックして拡大
3ページ

This instruction manual must be read by any person installing or operating this tool with particular attention to the

following safety warnings and instructions.

Always wear impact-resistant eye protection during operation of the tool. The grade of protection required should

be assessed for each use.

Use of the tool can expose the operator’s hands to hazards, including crushing, impacts, cuts and abrasions and

heat. Wear suitable gloves to protect hands.

Use hearing protection in accordance with employer’s instructions and as required by occupational health and

safety regulations.

1. SAFETY DEFINITIONS

The defi nitions below describe the severity for each signal word. Please read the manual and pay attention to these symbols.

injury.

in property damage. Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operating instructions before using this equipment. When using

power tools, basic safety precautions must always be followed to reduce the risk of personal injury. When the tool is operated it must not be held in the hand or be in contact with any part of the body. There is a possibility of a shear injury when the piston retracts.

SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE.

1.1 GENERAL SAFETY RULEs

  • For multiple hazards, read and understand the safety instructions before installing, operating, repairing, maintaining, changing accessories on, or working near the tool. Failure to do so can result in serious bodily injury.
  • Only qualifi ed and trained operators must install, adjust or use the tool.
  • DO NOT use outside the design intent of placing STANLEY Engineered Fastening Blind Rivets.
  • Use only parts, fasteners, and accessories recommended by the manufacturer.
  • DO NOT modify the tool. Modifi cations can reduce the eff ectiveness of safety measures and increase the risks to the operator. Any modifi cation to the tool undertaken by the customer will be the customer’s entire responsibility and void any applicable warranties.
  • Do not discard the safety instructions; give them to the operator.
  • Do not use the tool if it has been damaged.
  • Prior to use, check for misalignment or binding of moving parts, breakage of parts, and any other condition that aff ects the tool’s operation. If damaged, have the tool serviced before using. Remove any adjusting key or wrench before use.
  • Tools shall be inspected periodically to verify that the ratings and markings required by this part of ISO 11148 are legibly marked on the tool. The employer/user shall contact the manufacturer to obtain replacement marking labels when necessary.
  • The tool must be maintained in a safe working condition at all times and examined at regular intervals for damage and function by trained personnel. Any dismantling procedure will be undertaken only by trained personnel. Do not dismantle this tool without prior reference to the maintenance instructions.

1.2 PROJECTILE HARZARDS

  • Disconnect the tool from the hydraulic supply unit before performing any maintenance, attempting to adjust, fi t or remove a nose assembly or accessories.
  • Be aware that failure of the workpiece or accessories, or even of the inserted tool itself can generate high-velocity projectiles.
  • Always wear impact-resistant eye protection during operation of the tool. The grade of protection required should be assessed for each use.
  • The risks to others should also be assessed at this time.
  • Ensure that the workpiece is securely fi xed.
  • Check that the means of protection from ejection of fastener and/or mandrel is in place and is operative.
  • Warn against the possible forcible ejection of mandrels from the front of the tool.
Page 4 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — 1.7 NOISE HAZARDS
4ページ · クリックして拡大
4ページ
  • DO NOT operate a tool that is directed towards any person(s).

1.3 OPERATING HAZARDS

  • When the tool is operated it must not be held in the hand or be in contact with any part of the body. There is a possibility of a shear injury when the piston retracts.
  • Use of the tool can expose the operator’s hands to hazards, including crushing, impacts, cuts and abrasions and heat. Wear suitable gloves to protect hands.
  • Release the start-and-stop device in the case of an interruption of the hydraulic supply.
  • Use only lubricants recommended by the manufacturer.
  • Contact with hydraulic fl uid should be avoided. To minimise the possibility of rashes, care should be taken to wash thoroughly if contact occurs.
  • Material Safety Data Sheets for all hydraulic oils and lubricants is available on request from your tool supplier.
  • If the tool is fi xed to a suspension device, make sure that the fi xation is secure.
  • Beware of the risk of crushing or pinching if nose equipment is not fi tted.
  • DO NOT operate tool with the nose casing removed.
  • When carrying the tool from place to place keep hands away from the trigger to avoid inadvertent activation.
  • DO NOT abuse the tool by dropping or using it as a hammer.
  • Care should be taken to ensure that spent mandrels do not create a hazard.

1.4 REPETITIVE MOTIONS HAZARDS

  • When using the tool, the operator can experience discomfort in the hands, arms, shoulders, neck or other parts of the body.
  • While using the tool, the operator should adopt a comfortable posture whilst maintaining a secure footing and avoiding awkward or off -balance postures. The operator should change posture during extended tasks; this can help avoid discomfort and fatigue.
  • If the operator experiences symptoms such as persistent or recurring discomfort, pain, throbbing, aching, tingling, numbness, burning sensations or stiff ness, these warning signs should not be ignored. The operator should tell the employer and consult a qualifi ed health professional.

1.5 ACCESSORY HAZARDS

  • Disconnect the tool from the hydraulic supply before fi tting or removing the nose assembly or accessory.
  • Use only sizes and types of accessories and consumables that are recommended by the manufacturer of the tool; do not use other types or sizes of accessories or consumables.

1.6 WORKPLACE HAZARDS

  • Slips, trips and falls are major causes of workplace injury. Be aware of slippery surfaces caused by use of the tool and also of trip hazards caused by the air line or hydraulic hose.
  • Proceed with care in unfamiliar surroundings. There can be hidden hazards, such as electricity or other utility lines.
  • The tool is not intended for use in potentially explosive atmospheres and is not insulated against contact with electric power.
  • Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by use of the tool.
  • Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves away from moving parts. Loose clothes, jewellery or long hair can be caught in moving parts.
  • Care should be taken to ensure that spent mandrels do not create a hazard.

1.7 NOISE HAZARDS

  • Exposure to high noise levels can cause permanent, disabling hearing loss and other problems, such as tinnitus (ringing, buzzing, whistling or humming in the ears). Therefore, risk assessment and the implementation of appropriate controls for these hazards are essential.
  • Appropriate controls to reduce the risk may include actions such as damping materials to prevent workpieces from “ringing”.
  • Use hearing protection in accordance with employer’s instructions and as required by occupational health and safety regulations.
  • Operate and maintain the tool as recommended in the instruction manual, to prevent an unnecessary increase in the noise level.
Page 5 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — 1.8 ADDITIONAL SAFETY INSTRUCTIONS FOR HYDRAULIC POWER TOOLS
5ページ · クリックして拡大
5ページ

1.8 ADDITIONAL SAFETY INSTRUCTIONS FOR HYDRAULIC POWER TOOLS

  • The operating hydraulic supply must not exceed 400 bar (5800 PSI).
  • Oil under pressure can cause severe injury.
  • Do not fi t fl exible hydraulic hoses rated at less than 700 bar (10,000 PSI) working pressure at a fl ow rate of 2.73 l/min (200 in 3 /min).
  • Disconnect hydraulic hoses from the pump unit when tool is not in use, before changing accessories or when making repairs.
  • Whipping hoses can cause severe injury. Always check for damaged or loose hoses and fi ttings.
  • Prior to use, inspect hydraulic hoses for damage, all hydraulic connections must be clean, fully engaged and tight before operation. Do not drop heavy objects on hoses. A sharp impact may cause internal damage and lead to premature hose failure.
  • Whenever universal twist couplings (claw couplings) are used, lock pins shall be installed and whipcheck safety cables shall be used to safeguard against possible hose-to-tool or hose-to-hose connection failure.
  • DO NOT lift the placing module by the hose. Always use the placing module body.
  • Keep dirt and foreign matter out of the hydraulic system of the tool as this will cause the tool to malfunction.
  • Use only clean oil and fi lling equipment.
  • Only recommended hydraulic fl uids may be used.
  • Maximum temperature of the hydraulic fl uid at the inlet is 110°C (230°F).

STANLEY Engineered Fastening policy is one of continuous product development and improvement and we reserve

the right to change the specifi cation of any product without prior notice.

Page 6 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — 2.3 TOOL DIMENSIONS
6ページ · クリックして拡大
6ページ

2. SPE CIFICATION

2.1 INTENT OF USE

The 71504 Module is principally a piston and cylinder assembly. When coupled hydraulically to a compatible hydraulic power source and the relevant nose assembly is attached, it is then used to install blind rivets up to 6.4mm (1/4”) in diameter, in Industrial Environments.

The placing module may only be used in accordance with the operating instructions for placing Stanley Engineered Fastening structural rivets.

DO NOT use under wet conditions or in the presence of fl ammable liquids or gases.

The safety instructions must be followed at all times.

2.2 TOOL SPECIFICATION

SPECIFICATIONMETRICIMPERIAL Force:Pull at stated pull pressure22.7 kN5103 lbf Pressure:Maximum400 bar5800 PSI Stroke:Piston Stroke26.0 mm1.125 in Piston Bore Diameter:Minimum6.4 mm0.25 in Weight:Without nose equipment1.98 kg4.36 lbs

2.3 TOOL DIMENSIONS

Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) — 2.3 TOOL DIMENSIONS diagram (page 6)
図 2

All dimensions are shown in millimetres.

Page 7 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — 5.4 SERVICE KIT
7ページ · クリックして拡大
7ページ

3. PUTTING IN SERVICE

IMPORTANT - R EAD THE SAFETY RULES ON 3 - 5 AND THE TECHNICAL MANUAL SUPPLIED WITH THE COMPLETE MACHINE CAREFULLY BEFORE PUTTING INTO SERVICE.

THE MODULE IS DESIGNED TO OPERATE AS PART OF A COMPLETE AUTOMATED OR SEMI-AUTOMATED MACHINE. WHEN THE TOOL IS CYCLED IT MUST NOT BE HELD IN THE HAND OR BE IN CONTACT WITH ANY PART OF THE BODY. THERE IS A POSSIBILITY OF A SHEAR INJURY WHEN THE PISTON RETRACTS.

Instructions on installing and removing the module from the machine frame will be included in the Technical Manual supplied with the machine. The Technical Manual will include full instructions on putting the module into service, together with instructions on the dismantling, maintenance and assembly of the Nose Equipment.

4. OPERATING INSTRUCTIONS

Refer to the Technical Manual supplied with the machine for operating instructions.

5. SERVICING THE TOOL

THE EMPLOYER IS RESPONSIBLE FOR ENSURING THAT TOOL MAINTENANCE INSTRUCTIONS ARE GIVEN TO THE APPROPRIATE PERSONNEL. THE OPERATOR SHOULD NOT BE INVOLVED IN MAINTENANCE OR REPAIR OF THE TOOL UNLESS PROPERLY TRAINED. THE TOOL SHALL BE EXAMINED REGULARLY FOR DAMAGE AND MALFUNCTION.

Refer to the Technical Manual supplied with the machine for full service instructions.

5.1 DAILY SERVICING

  • Check placing tool, hoses and connectors for oil leaks.
  • Worn or damaged hoses and connectors should be replaced.
  • Check that the stroke of tool meets the specifi cation.
  • Check that the supply pressure is correct and does not exceed 400 bar.

5.2 WEEKLY SERVICING

  • Dismantle and clean the nose equipment, especially the jaws, as described in the Technical Manual for the Machine.
  • Check for oil leaks in placing tool, hoses and quick couplers.

5.3 ANNUAL SERVICING / EVERY 500K OPERATIONS

  • Every 500,000 cycles the tool should be completely dismantled and new components should be used where worn, damaged or as recommended. All O-rings, back-up rings and seals should be renewed and lubricated with MolyKote® 111 grease before assembling.

5.4 SERVICE KIT

For a complete service the following Service Kit is available:

SERVICE KIT: 07900-06540 PART NUMBERDESCRIPTIONPART NUMBERDESCRIPTION 07900-00233Spanner07900-00558Spanner 07900-00006Spatula07900-00004Internal Circlip Pliers 07900-00012Spanner 9/16” x 5/8” A/F07900-00578Assembly Bullet 07900-00015Spanner 5/8” x 11/16” A/F07992-00020Moly-lithium Grease 07900-00429Spanner Assembly
Page 8 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — 5.7 PROTECTING THE ENVIRONMENT
8ページ · クリックして拡大
8ページ

5.5 HYDRAULIC OIL

The recommended oil for priming is Hyspin® VG32 available in 0.5l (part number 07992-00002) or one gallon containers (part number 07992-00006).

5.6 DISMANTLING INSTRUCTIONS

Instructions on installing and removing the module from the machine frame will be included in the Technical Manual supplied with the machine. The Technical Manual will include full instructions on the dismantling, maintenance and assembly of the tool.

Before Dismantling:

  • Remove the module from the machine.
  • Remove the nose assembly from the module as per the instructions in the Technical Manual supplied with the machine.
  • The potentially dangerous substances that could have deposited on the machine as a result of work processes must be removed before maintenance.

For a complete service of the tool, we advise that you proceed with dismantling the tool in the order shown on pages 7 to 8. After dismantling the tool we recommend that you replace all seals.

Dismantling Instructions:

  • Remove the nose casing extension (item 23) using spanner 07900-00233.
  • Using spanner 07900-00435, remove body sleeve (item 18).
  • Remove spring guide (item 19).
  • Remove spring (item 15).
  • Using spanner assembly 07900-00429 to restrain piston (item 16) remove adaptor (item 22) using spanner 07900-00558.
  • Remove piston (item16) from body (item 17).
  • Using internal circlip pliers 07900-00004 remove circlip (item 9).
  • Remove head retaining plate (item 14).
  • Remove seal (item 6) using spatula 07900-00006.
  • Remove seals (item 4) and (item 5).
  • Note – when removing internal seals it is necessary to use a pointed probe. Care must be taken not to damage sealing surfaces.

Assembly Instructions:

  • Clean all the parts thoroughly. Inspect and replace any parts that are worn or damaged. Lubricate the seals (items 4, 5 & 6) and the bore of the body (item 17), with Moly Lithium Grease (07992-00020).
  • Assembly is the reverse procedure for dismantling.
  • Ensure that the seals (Items 4, 5 & 6) and the wiper (Item 7), are replaced in the correct orientation. Lubricate all seals and housings, with Molylithium Grease (07992-00020).
  • Prior to assembly of piston (item 16) into the body (item 17), fi t assembly bullet 07900-00578 over the M12 thread on the piston.
  • It is important to adhere adapter (item 22) to piston (item 16) on assembly using Loctite 242.

All item numbers refer to the General Assembly and Part List in section 6.0.

5.7 PROTECTING THE ENVIRONMENT

  • Assure conformity with applicable disposal regulations. Dispose all waste products at an approved waste facility or site so as not to expose personnel and the environment to hazards.
Page 9 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — 6.1 GENERAL ASSEMBLY
9ページ · クリックして拡大
9ページ

6. GENERAL ASSEMBLY AND PART LIST

6.1 GENERAL ASSEMBLY

Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) — 6.1 GENERAL ASSEMBLY diagram (page 9)
図 3
Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) — 6.1 GENERAL ASSEMBLY diagram (page 9)
図 4
Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) — 6.1 GENERAL ASSEMBLY diagram (page 9)
図 5
Page 10 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — 7.1 HYSPIN VG32 OIL SAFETY DATA
10ページ · クリックして拡大
10ページ

6.2 PARTS LIST

71504-02000 Parts List ITEMPART NUMBERDESCRIPTIONQTY. 107001-00404SOCKET SET SCREW1 207001-00436SET SCREW1 307005-01756PLUG CLEAR PLASTIC1 407003-00026O RING SEAL1 507003-00245ROD SEAL1 607003-00283PISTON SEAL1 707003-00202WIPER RING1 807007-01505SAFETY CAP1 907004-00033CIRCLIP1 1007007-00472Ø5 STEEL BALL1 1107008-00375BANJO FLOW RESTRICTOR1 1207007-02223ADDRESS LABEL1 1373200-02022SAFETY LABEL1 1407490-00316HEAD RETAINING PLATE1 1571504-02003SPRING1 1671504-02001PISTON1 1771504-02002BODY1 1807654-00203BODY SLEEVE1 1907654-00204SPRING GUIDE1 2007001-00005HAMMER DRIVE SCREW2 2107654-00205LABEL1 2271504-02004ADAPTOR1 2371504-02005NOSE CASING EXTENSION1

7. SAFETY DATA

7.1 HYSPIN VG32 OIL SAFETY DATA

SKIN: Unlikely to cause harm to the skin on brief or occasional contact but prolonged or exposure may lead to dermatitis. Wash skin thoroughly with soap and water as soon as reasonably practicable. Remove heavily contaminated clothing and wash underlying skin. Launder contaminated clothing. ORAL: Unlikely to cause harm if accidentally swallowed in small doses, though larger quantities may cause nausea and diarrhoea. If contamination of the mouth occurs, wash out thoroughly with water. Except as a deliberate act, the ingestion of large amounts of product is unlikely. If it should occur, do not induce vomiting; obtain medical advice. Take person to nearest medical centre. EYES: Unlikely to cause more than transient stinging or redness if accidental eye contact occurs. Wash eyes thoroughly with copious quantities of water, ensuring eyelids are held open. Obtain medical advice if any pain or redness develops or persists.

Disposal: Remove all spills with inert absorbent material. Ventilate spill area. Place contaminated materials in a disposable container and dispose in a manner consistent with local regulations.

Protecting the Environment: Separate collection. This product must not be disposed of with normal waste. Should you fi nd one day that your product needs replacement, or if it is of no further use to you, do not dispose of it with regular waste. Make this product available for separate collection. Separate collection of used products and packaging allows materials to be recycled and used again. Re-use of recycled materials helps prevent environmental pollution and reduces the demand for raw materials. Local regulations may provide for separate collection of electrical products, at municipal waste sites or by the retailer when you purchase a new product. You can check the location of your nearest authorized repair agent by contacting your local STANLEY Engineered Fastening offi ce at the address indicated in this manual. Alternatively, a list of authorized

First Aid

Page 11 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — 7.3 Molykote® 111 GREASE - SAFTEY DATA
11ページ · クリックして拡大
11ページ

repair agents and full details of our after-sales service and contacts are available on the Internet at: www.StanleyEngineeredFastening.com

Fire: FLASH POINT: 200°C. Extinguish with dry, chemical, foam or carbon dioxide. Do not enter confi ned space without self-contained breathing apparatus. Handling: Use barrier cream or oil resistant gloves. Storage: Undercover and consistent with local regulations for infl ammable material.

7.2 MOLYLITHIUM GREASE EP 3753 - SAFETY DATA

Grease can be ordered as a single item, the part number is shown in the Service Kit page 7.

FIRST AID SKIN: As the grease is completely water resistant it is best removed with an approved emulsifying skin cleaner. INGESTION: Ensure the individual drinks 30ml Milk of Magnesia, preferably in a cup of milk. EYES: Irritant but not harmful. Irrigate with water and seek medical attention.

FIRE FLASH POINT: Above 220°C. Not classifi ed as fl ammable. Suitable extinguishing media: CO2, Halon or water spray if applied by an experienced operator.

ENVIRONMENT Scrape up for incineration or disposal on approved site.

HANDLING Use barrier cream or oil resistant gloves

STORAGE Away from heat and oxidising agent.

7.3 Molykote® 111 GREASE - SAFTEY DATA

Grease can be ordered as a single item, the part number is shown in the Service Kit page 7.

FIRST AID SKIN: No fi rst aid should be needed. INGESTION: No fi rst aid should be needed. EYES: No fi rst aid should be needed. INHALATION: No fi rst aid should be needed.

FIRE FLASH POINT: Above 101.1°C. (closed cup) Explosive Properties: No Suitable Extinguishing Media: Carbon Dioxide Foam, Dry Powder or fi ne water spray. Water can be used to cool fi re exposed containers.

ENVIRONMENT No adverse eff ects are predicted.

HANDLING General ventilation is recommended. Avoid eye contact.

STORAGE Do not store with oxidizing agents. Keep container closed and store away from water or moisture.

Page 12 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — Description: 71504 Hydro-Pneumatic Module for Blind Rivets
12ページ · クリックして拡大
12ページ

8. EC DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY

We, Stanley Engineered Fastening, Stanley House, Works Road, Letchworth Garden City, Hertfordshire, SG6 1JY UNITED KINGDOM, declare under our sole responsibility that the product:

Description: 71504 Hydro-Pneumatic Module for Blind Rivets

Model: 71504

to which this declaration relates is in conformity with the following harmonized standards:

ISO 12100:2010EN ISO 11148-1:2011 EN ISO 4413:2010ES100118-rev 17:2017

Technical documentation is compiled in accordance with Annex VII section B, in accordance with the following Directive: 2006/42/EC The Machinery Directive (Statutory Instruments 2008 No 1597 - The Supply of Machinery (Safety) Regulations refers).

All relevant basic safety and health protection requirements of Directive 2006/42/EC are complied with up to the interface cell described in the operating instructions, Section 3 and 4.

The undersigned makes this declaration on behalf of STANLEY Engineered Fastening

Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) — Description: 71504 Hydro-Pneumatic Module for Blind Rivets diagram (page 12)
図 6 · Description: 71504 Hydro-Pneumatic Module for Blind…

A. K. Seewraj Director of Engineering, UK Avdel UK Limited, Stanley House, Works Road, Letchworth Garden City, Hertfordshire, SG6 1JY UNITED KINGDOM

Place of IssueLetchworth Garden City, UK
Date of Issue01-01-2021

The undersigned is responsible for compilation of the technical file for products sold in the European Union and makes this declaration on behalf of Stanley Engineered Fastening.

Matthias Appel Team Leader Technical Documentation Stanley Engineered Fastening, Tucker GmbH, Max-Eyth-Str.1, 35394 Gießen, Germany

This machinery is in conformity with Machinery Directive 2006/42/EC

Page 13 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — ISO 12100:2010 EN ISO 11148-1:2011
13ページ · クリックして拡大
13ページ

9. UK DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY

We, Stanley Engineered Fastening, Stanley House, Works Road, Letchworth Garden City, Hertfordshire, SG6 1JY UNITED KINGDOM, declare under our sole responsibility that the product:

Description: 71504 Hydro-Pneumatic Module for Blind Rivets

Model: 71504

to which this declaration relates is in conformity with the following designated standards:

ISO 12100:2010 EN ISO 11148-1:2011

EN ISO 4413:2010 ES100118-rev 17:2017

Technical documentation is compiled in accordance with the Supply of Machinery (Safety) Regulations 2008, S.I. 2008/1597 (as amended).

All relevant basic safety and health protection requirements of the Supply of Machinery (Safety) Regulations 2008, S.I. 2008/1597 (as amended) are complied with up to the interface cell described in the operating instructions, Section 3 and 4.

The undersigned makes this declaration on behalf of STANLEY Engineered Fastening

A. K. Seewraj Director of Engineering, UK Avdel UK Limited, Stanley House, Works Road, Letchworth Garden City, Hertfordshire, SG6 1JY UNITED KINGDOM

Place of IssueLetchworth Garden City, UK
Date of Issue01-01-2021

This machinery is in conformity with Supply of Machinery (Safety) Regulations 2008, S.I. 2008/1597 (as amended)

Page 14 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — 10. PROTECT YOUR INVESTMENT!
14ページ · クリックして拡大
14ページ

10. PROTECT YOUR INVESTMENT!

Stanley® Engineered Fastening BLIND RIVET TOOL WARRANTY STANLEY® Engineered Fastening warrants that all power tools have been carefully manufactured and that they will be free from defect in material and workmanship under normal use and service for a period of one (1) year.

This warranty applies to the fi rst-time purchaser of the tool for original use only.

Exclusions:

Normal wear and tear. Periodic maintenance, repair and replacement parts due to normal wear and tear are excluded from coverage.

Abuse & Misuse. Defect or damage that results from improper operation, storage, misuse or abuse, accident or neglect, such as physical damage are excluded from coverage.

Unauthorized Service or Modifi cation. Defects or damages resulting from service, testing adjustment, installation, maintenance, alteration or modifi cation in any way by anyone other than STANLEY® Engineered Fastening, or its authorized service centres, are excluded from coverage.

All other warranties, whether expressed or implied, including any warranties of merchantability or fi tness for purpose are hereby excluded.

Should this tool fail to meet the warranty, promptly return the tool to our factory authorized service centre location nearest you. For a list of STANLEY® Engineered Fastening Authorized Service Centres in the US or Canada, contact us at our toll free number (877)364 2781.

Outside the US and Canada, visit our website www.StanleyEngineeredFastening.com to fi nd your nearest STANLEY Engineered Fastening location.

STANLEY Engineered Fastening will then replace, free of charge, any part or parts found by us to be defective due to faulty material or workmanship and return the tool prepaid. This represents our sole obligation under this warranty. In no event shall STANLEY Engineered Fastening be liable for any consequential or special damages arising out of the purchase or use of this tool.

Register Your Blind Rivet Tool online.

To register your warranty online, visit us at https://www.stanleyengineeredfastening.com/support/warranty-registration-form

Thank you for choosing a STANLEY® Engineered Fastening’s Stanley Assembly Technologies Brand tool.

Page 15 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — 10. PROTECT YOUR INVESTMENT!
15ページ · クリックして拡大
15ページ
Page 15 of the Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) user manual — 10. PROTECT YOUR INVESTMENT!

Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504)について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504)に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Stanley Module for Blind Rivets Hydro Pneumatic Power Module (71504) 取扱説明書(PDF)

44 ページ·2.8 MB·電動工具·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…