SERVICE MANUAL

EN Hydro-Pneumatic Power Module
ZHS 液压气动模块
71504 Module for Blind Rivets Hydro-Pneumatic Power Module

©2021 STANLEY Black & Decker All rights reserved.
The information provided may not be reproduced and/or made public in any way and through any means (electronically or mechanically) without prior explicit and written permission from STANLEY Engineered Fastening. The information provided is based on the data known at the moment of the introduction of this product. STANLEY Engineered Fastening pursues a policy of continuous product improvement and therefore the products may be subject to change. The information provided is applicable to the product as delivered by STANLEY Engineered Fastening. Therefore, STANLEY Engineered Fastening cannot be held liable for any damage resulting from deviations from the original specifi cations of the product.
The information available has been composed with the utmost care. However, STANLEY Engineered Fastening will not accept any liability with respect to any faults in the information nor for the consequences thereof. STANLEY Engineered Fastening will not accept any liability for damage resulting from activities carried out by third parties. The working names, trade names, registered trademarks, etc. used by STANLEY Engineered Fastening should not be considered as being free, pursuant to the legislation with respect to the protection of trademarks.
1. SAFETY DEFINITIONS 3 1.1 GENERAL SAFETY RULEs 3 1.2 PROJECTILE HARZARDS 3 1.3 OPERATING HAZARDS 4 1.4 REPETITIVE MOTIONS HAZARDS 4 1.5 ACCESSORY HAZARDS 4 1.6 WORKPLACE HAZARDS 4 1.7 NOISE HAZARDS 4 1.8 ADDITIONAL SAFETY INSTRUCTIONS FOR HYDRAULIC POWER TOOLS 5 2. SPECIFICATION 6 2.1 INTENT OF USE 6 2.2 TOOL SPECIFICATION 6 2.3 TOOL DIMENSIONS 6 3. PUTTING IN SERVICE 7 4. OPERATING INSTRUCTIONS 7 5. SERVICING THE TOOL 7 5.1 DAILY SERVICING 7 5.2 WEEKLY SERVICING 7 5.3 ANNUAL SERVICING / EVERY 500K OPERATIONS 7 5.4 SERVICE KIT 7 5.5 HYDRAULIC OIL 8 5.6 DISMANTLING INSTRUCTIONS 8 5.7 PROTECTING THE ENVIRONMENT 8 6. GENERAL ASSEMBLY AND PART LIST 9 6.1 GENERAL ASSEMBLY 9 6.2 PARTS LIST 10 7. SAFETY DATA 10 7.1 HYSPIN VG32 OIL SAFETY DATA 10 7.2 MOLYLITHIUM GREASE EP 3753 - SAFETY DATA 11 7.3 Molykote® 111 GREASE - SAFTEY DATA 11 8. EC DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY 12 9. UK DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY 13 10. PROTECT YOUR INVESTMENT! 14

This instruction manual must be read by any person installing or operating this tool with particular attention to the
following safety warnings and instructions.
Always wear impact-resistant eye protection during operation of the tool. The grade of protection required should
be assessed for each use.
Use of the tool can expose the operator’s hands to hazards, including crushing, impacts, cuts and abrasions and
heat. Wear suitable gloves to protect hands.
Use hearing protection in accordance with employer’s instructions and as required by occupational health and
safety regulations.
The defi nitions below describe the severity for each signal word. Please read the manual and pay attention to these symbols.
injury.
in property damage. Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operating instructions before using this equipment. When using
power tools, basic safety precautions must always be followed to reduce the risk of personal injury. When the tool is operated it must not be held in the hand or be in contact with any part of the body. There is a possibility of a shear injury when the piston retracts.
SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE.


STANLEY Engineered Fastening policy is one of continuous product development and improvement and we reserve
the right to change the specifi cation of any product without prior notice.

The 71504 Module is principally a piston and cylinder assembly. When coupled hydraulically to a compatible hydraulic power source and the relevant nose assembly is attached, it is then used to install blind rivets up to 6.4mm (1/4”) in diameter, in Industrial Environments.
The placing module may only be used in accordance with the operating instructions for placing Stanley Engineered Fastening structural rivets.
DO NOT use under wet conditions or in the presence of fl ammable liquids or gases.
The safety instructions must be followed at all times.

All dimensions are shown in millimetres.

IMPORTANT - R EAD THE SAFETY RULES ON 3 - 5 AND THE TECHNICAL MANUAL SUPPLIED WITH THE COMPLETE MACHINE CAREFULLY BEFORE PUTTING INTO SERVICE.
THE MODULE IS DESIGNED TO OPERATE AS PART OF A COMPLETE AUTOMATED OR SEMI-AUTOMATED MACHINE. WHEN THE TOOL IS CYCLED IT MUST NOT BE HELD IN THE HAND OR BE IN CONTACT WITH ANY PART OF THE BODY. THERE IS A POSSIBILITY OF A SHEAR INJURY WHEN THE PISTON RETRACTS.
Instructions on installing and removing the module from the machine frame will be included in the Technical Manual supplied with the machine. The Technical Manual will include full instructions on putting the module into service, together with instructions on the dismantling, maintenance and assembly of the Nose Equipment.
Refer to the Technical Manual supplied with the machine for operating instructions.
THE EMPLOYER IS RESPONSIBLE FOR ENSURING THAT TOOL MAINTENANCE INSTRUCTIONS ARE GIVEN TO THE APPROPRIATE PERSONNEL. THE OPERATOR SHOULD NOT BE INVOLVED IN MAINTENANCE OR REPAIR OF THE TOOL UNLESS PROPERLY TRAINED. THE TOOL SHALL BE EXAMINED REGULARLY FOR DAMAGE AND MALFUNCTION.
Refer to the Technical Manual supplied with the machine for full service instructions.
For a complete service the following Service Kit is available:

The recommended oil for priming is Hyspin® VG32 available in 0.5l (part number 07992-00002) or one gallon containers (part number 07992-00006).
Instructions on installing and removing the module from the machine frame will be included in the Technical Manual supplied with the machine. The Technical Manual will include full instructions on the dismantling, maintenance and assembly of the tool.
Before Dismantling:
For a complete service of the tool, we advise that you proceed with dismantling the tool in the order shown on pages 7 to 8. After dismantling the tool we recommend that you replace all seals.
Dismantling Instructions:
Assembly Instructions:
All item numbers refer to the General Assembly and Part List in section 6.0.





SKIN: Unlikely to cause harm to the skin on brief or occasional contact but prolonged or exposure may lead to dermatitis. Wash skin thoroughly with soap and water as soon as reasonably practicable. Remove heavily contaminated clothing and wash underlying skin. Launder contaminated clothing. ORAL: Unlikely to cause harm if accidentally swallowed in small doses, though larger quantities may cause nausea and diarrhoea. If contamination of the mouth occurs, wash out thoroughly with water. Except as a deliberate act, the ingestion of large amounts of product is unlikely. If it should occur, do not induce vomiting; obtain medical advice. Take person to nearest medical centre. EYES: Unlikely to cause more than transient stinging or redness if accidental eye contact occurs. Wash eyes thoroughly with copious quantities of water, ensuring eyelids are held open. Obtain medical advice if any pain or redness develops or persists.
Disposal: Remove all spills with inert absorbent material. Ventilate spill area. Place contaminated materials in a disposable container and dispose in a manner consistent with local regulations.
Protecting the Environment: Separate collection. This product must not be disposed of with normal waste. Should you fi nd one day that your product needs replacement, or if it is of no further use to you, do not dispose of it with regular waste. Make this product available for separate collection. Separate collection of used products and packaging allows materials to be recycled and used again. Re-use of recycled materials helps prevent environmental pollution and reduces the demand for raw materials. Local regulations may provide for separate collection of electrical products, at municipal waste sites or by the retailer when you purchase a new product. You can check the location of your nearest authorized repair agent by contacting your local STANLEY Engineered Fastening offi ce at the address indicated in this manual. Alternatively, a list of authorized
First Aid

repair agents and full details of our after-sales service and contacts are available on the Internet at: www.StanleyEngineeredFastening.com
Fire: FLASH POINT: 200°C. Extinguish with dry, chemical, foam or carbon dioxide. Do not enter confi ned space without self-contained breathing apparatus. Handling: Use barrier cream or oil resistant gloves. Storage: Undercover and consistent with local regulations for infl ammable material.
Grease can be ordered as a single item, the part number is shown in the Service Kit page 7.
FIRST AID SKIN: As the grease is completely water resistant it is best removed with an approved emulsifying skin cleaner. INGESTION: Ensure the individual drinks 30ml Milk of Magnesia, preferably in a cup of milk. EYES: Irritant but not harmful. Irrigate with water and seek medical attention.
FIRE FLASH POINT: Above 220°C. Not classifi ed as fl ammable. Suitable extinguishing media: CO2, Halon or water spray if applied by an experienced operator.
ENVIRONMENT Scrape up for incineration or disposal on approved site.
HANDLING Use barrier cream or oil resistant gloves
STORAGE Away from heat and oxidising agent.
Grease can be ordered as a single item, the part number is shown in the Service Kit page 7.
FIRST AID SKIN: No fi rst aid should be needed. INGESTION: No fi rst aid should be needed. EYES: No fi rst aid should be needed. INHALATION: No fi rst aid should be needed.
FIRE FLASH POINT: Above 101.1°C. (closed cup) Explosive Properties: No Suitable Extinguishing Media: Carbon Dioxide Foam, Dry Powder or fi ne water spray. Water can be used to cool fi re exposed containers.
ENVIRONMENT No adverse eff ects are predicted.
HANDLING General ventilation is recommended. Avoid eye contact.
STORAGE Do not store with oxidizing agents. Keep container closed and store away from water or moisture.

We, Stanley Engineered Fastening, Stanley House, Works Road, Letchworth Garden City, Hertfordshire, SG6 1JY UNITED KINGDOM, declare under our sole responsibility that the product:
Model: 71504
to which this declaration relates is in conformity with the following harmonized standards:
Technical documentation is compiled in accordance with Annex VII section B, in accordance with the following Directive: 2006/42/EC The Machinery Directive (Statutory Instruments 2008 No 1597 - The Supply of Machinery (Safety) Regulations refers).
All relevant basic safety and health protection requirements of Directive 2006/42/EC are complied with up to the interface cell described in the operating instructions, Section 3 and 4.
The undersigned makes this declaration on behalf of STANLEY Engineered Fastening

A. K. Seewraj Director of Engineering, UK Avdel UK Limited, Stanley House, Works Road, Letchworth Garden City, Hertfordshire, SG6 1JY UNITED KINGDOM
The undersigned is responsible for compilation of the technical file for products sold in the European Union and makes this declaration on behalf of Stanley Engineered Fastening.
Matthias Appel Team Leader Technical Documentation Stanley Engineered Fastening, Tucker GmbH, Max-Eyth-Str.1, 35394 Gießen, Germany
This machinery is in conformity with Machinery Directive 2006/42/EC

We, Stanley Engineered Fastening, Stanley House, Works Road, Letchworth Garden City, Hertfordshire, SG6 1JY UNITED KINGDOM, declare under our sole responsibility that the product:
Model: 71504
to which this declaration relates is in conformity with the following designated standards:
EN ISO 4413:2010 ES100118-rev 17:2017
Technical documentation is compiled in accordance with the Supply of Machinery (Safety) Regulations 2008, S.I. 2008/1597 (as amended).
All relevant basic safety and health protection requirements of the Supply of Machinery (Safety) Regulations 2008, S.I. 2008/1597 (as amended) are complied with up to the interface cell described in the operating instructions, Section 3 and 4.
The undersigned makes this declaration on behalf of STANLEY Engineered Fastening
A. K. Seewraj Director of Engineering, UK Avdel UK Limited, Stanley House, Works Road, Letchworth Garden City, Hertfordshire, SG6 1JY UNITED KINGDOM
This machinery is in conformity with Supply of Machinery (Safety) Regulations 2008, S.I. 2008/1597 (as amended)

Stanley® Engineered Fastening BLIND RIVET TOOL WARRANTY STANLEY® Engineered Fastening warrants that all power tools have been carefully manufactured and that they will be free from defect in material and workmanship under normal use and service for a period of one (1) year.
This warranty applies to the fi rst-time purchaser of the tool for original use only.
Exclusions:
Normal wear and tear. Periodic maintenance, repair and replacement parts due to normal wear and tear are excluded from coverage.
Abuse & Misuse. Defect or damage that results from improper operation, storage, misuse or abuse, accident or neglect, such as physical damage are excluded from coverage.
Unauthorized Service or Modifi cation. Defects or damages resulting from service, testing adjustment, installation, maintenance, alteration or modifi cation in any way by anyone other than STANLEY® Engineered Fastening, or its authorized service centres, are excluded from coverage.
All other warranties, whether expressed or implied, including any warranties of merchantability or fi tness for purpose are hereby excluded.
Should this tool fail to meet the warranty, promptly return the tool to our factory authorized service centre location nearest you. For a list of STANLEY® Engineered Fastening Authorized Service Centres in the US or Canada, contact us at our toll free number (877)364 2781.
Outside the US and Canada, visit our website www.StanleyEngineeredFastening.com to fi nd your nearest STANLEY Engineered Fastening location.
STANLEY Engineered Fastening will then replace, free of charge, any part or parts found by us to be defective due to faulty material or workmanship and return the tool prepaid. This represents our sole obligation under this warranty. In no event shall STANLEY Engineered Fastening be liable for any consequential or special damages arising out of the purchase or use of this tool.
Register Your Blind Rivet Tool online.
To register your warranty online, visit us at https://www.stanleyengineeredfastening.com/support/warranty-registration-form
Thank you for choosing a STANLEY® Engineered Fastening’s Stanley Assembly Technologies Brand tool.


ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。