Dear Customer, We are delighted that you have decided to choose a high- quality product from our company.
1 About These Instructions 11 1.1 Further applicable documents 11 1.2 Warnings used 11 1.3 Symbols Used 12 1.4 Abbreviations Used 12
These instructions are divided into a text section and an illustrated section. The illustrated section can be found after the text section. These instructions are original instructions as outlined in the EC Directive 2006 / 42 / EC. Read through all of the instructions carefully: they contain important information about the product. Pay attention to and follow the instructions provided, particularly the safety instructions and warnings. Please keep these instructions in a safe place and make sure that they are available to all users at all times. The manufacturer is not liable for any damage caused as a result of non-compliance with the operating instructions and the information contained therein or due to non- customary use of the industrial door. Competent operation and proper maintenance influence the performance and availability of your industrial door to a considerable degree. Operating errors and inadequate maintenance lead to avoidable failures. Only competent operation and proper maintenance will guarantee satisfactory, long-term operational safety. Our customer service department will be happy to assist you. Please contact them if you have any questions after working through these operating instructions.
2 Safety Instructions 12 2.1 Intended use 12 2.2 Qualification of personnel 12 2.3 Standards and regulations 13 2.4 General safety instructions 13 2.5 Safety instructions for operation 13 2.6 Safety instructions for maintenance and troubleshooting 13
3 Fitting 13
4 Putting into Service 14 4.1 Setting the End-of-travel Positions 14 4.2 Test run 14
5 Operation 15 5.1 Instructed personnel 15 5.2 Normal wear 15 5.3 Emergency-OFF 15
6 Inspection and Maintenance 15 6.1 Maintenance intervals 16 6.2 Wearing parts 16
7 Control 16
8 Malfunctions and Troubleshooting 16
1 .1 Further applicable documents
9 Cleaning and Care 16
Depending on the ordered accessories, the delivery includes further instructions, e.g. instructions on how to control the door. Also read these instructions carefully and thoroughly. Pay attention to and follow the instructions provided herein, particularly the safety instructions and warnings.
10 Extension and Conversion 16
11 Dismantling and Disposal 16
53
1 .2 Warnings used
The general warning symbol indicates a danger that can lead to injury or death. In the text, the general warning symbol will be used in connection with the caution levels described below. In the illustrated Section, an additional instruction refers back to the explanation in the text.
Indicates a danger that leads directly to death or serious injuries.
Indicates a danger that can lead to death or serious injuries.
Indicates a danger that can lead to minor or moderate injuries.
Indicates a danger that can lead to damage or destruction of the product.

1 .3 Symbols Used
Correct arrangement or activity
Non-permissible arrangement or activity
Remove and dispose of component or packaging
Tighten the screws firmly
Tighten the screws by hand
See separate Fitting Instructions for the control or for the additional electrical control elements
1 .4 Abbreviations Used
EN European Standard OFF (FFL) Top edge of finished floor line LDB Clear passage width LDH Clear passage height
When used properly and for the intended purpose, industrial doors are reliable and safe to operate. Nevertheless, when used incorrectly or for purposes other than those intended, they can pose a risk. We therefore expressly draw your attention to the safety instructions contained in the individual chapters.
2 .1 Intended use
Industrial doors are used to close passage openings, to safely shut off rooms, to make machines safe and secure, to save energy costs, to improve the room air conditions and to accelerate the flow of materials. Intended use also includes paying attention to these instructions and observing inspection and maintenance conditions. Any other or further use is regarded as non-intended use. The manufacturer / supplier is not liable for any damage resulting from this. The risk is borne solely by the user.
Risk of trapping during door travel
2 .2 Qualification of personnel
Only qualified and instructed personnel may fit, operate and maintain the industrial door. Before commencing work the assigned personnel must read these instructions, particularly chapter 2. For safety reasons, specify distinct responsibilities for operation, maintenance and repairs to ensure that there are no unclear assignments.

2 .3 Standards and regulations
2 .5 Safety instructions for operation
At the least, observe the following European standards and directives, as well as country-specific safety requirements, standards and regulations.
EN 12445 Doors – Safety in use of power operated doors: Test methods EN 12453 Doors – Safety in use of power operated doors: Requirements EN 12604 Doors – Mechanical aspects: Requirements EN 12978 Doors – Safety devices for power operated doors: Requirements and test methods EN 60335-1 Safety of electrical equipment for domestic use and similar purposes – part 1: General requirements EN 61508 Functional safety of electrical / electronic / programmable electronic safety-related systems
2 .6 Safety instructions for maintenance and troubleshooting
VDE 0113 Electrical installations with electronic equipment VDE 0700 Safety of electronic devices for domestic use and similar purposes
BGV A3 Electrical installations and equipment ASR A1.7 Technical Rules for Workplaces
2 .4 General safety instructions
DANGER
Mains voltage! Contact with the mains voltage presents the danger of a deadly electric shock. For that reason, observe the following warnings under all circumstances:
▶ Only qualified electricians may perform work on the mains supply.
▶ Make sure that the on-site electrical installation complies with the applicable safety requirements.
▶ Ensure that the national regulations governing the operation of electrical equipment are complied with.
▶ Install the control unit for the industrial door operator within sight of the door.
▶ Before undertaking any electrical work, disconnect the system from the mains supply and ensure that it cannot be inadvertently turned on.
External voltage External voltage on the connecting terminals of the control will destroy the electronics.
▶ Do not apply any external voltage (e.g. mains voltage) to the connecting terminals of the control unit.
European Standards · VDE Regulations · Accident prevention regulations

Pull forces on electric cables Pull forces on electric cables will destroy the electronics.
Door movements Door travel may injure persons or damage objects.
▶ Never pull on the connecting leads of the electrical components.
▶ Make sure that no persons or objects are in the door's closing area during operation.
▶ Never use the door to lift objects or persons.
▶ Never reach into the guide, guide are, chain, toothed wheel or return pulley during door operation.
Concrete screws: Fitting subsurface cracked concrete C20 / 25, uncracked concrete C20 / 25 and brickwork.
Long shaft plug: Fitting subsurface concrete C12 / 15, gas concrete, sand-lime solid brick and solid brick.
Metric screws: Fitting subsurface steel, a suitable material thickness and strength must be observed.
4 .1 Setting the End-of-travel Positions
The end-of-travel positions of the door are set on the control cabinet.
For deviating subsurfaces, suitable fixing material must be selected (not in scope of delivery).
4 .1 .1 CLOSE end-of-travel position
To fit the door: 1 . Take precautionary measures to make the site safe. 2 . Check the on-site fitting conditions for the door (check measurements). 3 . Check the quality of the structure for its strength. 4 . Choose suitable fastenings. 5 . Unpack the door and check for damage. 6 . If delivered by a freight forwarder: Report any damage immediately. 7 . Check that the delivery is complete. The delivery must include: – 2 side elements – 1 top part with bottom track – 1 box containing hardware and operator – Operator and shaft cladding (option) 8 . Dispose of the packaging material. 9 . Fit the door as shown in the illustrated section.
Exceeding the CLOSE end-of-travel position If the door travels beyond the Close end-of-travel position, the bottom profile may be compressed. This could disrupt the diode deactivation of the light grille.
▶ Never exceed the CLOSE end-of-travel position.
▶ Set the CLOSE end-of-travel position so that the bottom profile makes full contact with the floor. If the guide is supported or the floor uneven, select the bottom edge of the side element as the end-of-travel position.
4 .1 .2 OPEN end-of-travel position
Exceeding the OPEN end-of-travel position If the door travels beyond the OPEN end-of-travel position, there is a risk of the door curtain slipping out of the side guides and sustaining damage.
▶ Never exceed the OPEN end-of-travel position.
Faulty door A faulty door may injure persons or damage objects.
▶ Set the OPEN end-of-travel position so that the lower edge of the bottom profile corresponds to the dimension for the door height.
▶ Only put the door into service if it is in perfect condition.
4 .2 Test run

5 .3 Emergency-OFF
▶ In emergency situations, de-energise the control by actuating the main switch, pulling the mains plug or, if available, actuating the red emergency-OFF button.
Door movements Door travel may injure persons or damage objects.
▶ Make sure that no persons or objects are in the door's closing area during operation.
▶ Make sure that the door has opened completely before driving in or out! Never drive or walk through doorways unless the door has reached the OPEN end-of-travel position.
Unmaintained doors There is a danger of injury and damage if the door is not regularly maintained. This will also void the warranty.
▶ Inspect and maintain the door regularly as described in these instructions or entrust this work to the manufacturer's service department.
▶ Whenever driving in or out of the opening, always check that the door curtain has travelled up far enough to provide the necessary passage height.
▶ Never use the door to lift objects or persons.
Mains voltage! Contact with the mains voltage presents the danger of a deadly electric shock.
▶ Do not reach into the guide or guide area while the door is in operation.
▶ Before undertaking any electrical work, disconnect the system from the mains supply and ensure that it cannot be inadvertently turned on.
Emergency operation devices Too frequent use of the emergency operation devices may damage them. This will also void the warranty for the door.
Door movements There is a danger of injury and damage if the door is actuated during inspection or maintenance work.
▶ Only use the emergency operation devices in the case of a power failure or during repair work.
▶ Before undertaking any work, disconnect the system from the mains supply and ensure that it cannot be inadvertently turned on.
Aggressive media, wind and heat Aggressive media, wind and heat may damage the door.
▶ If available, deactivate the emergency opening lever / handle.
▶ Protect the door from aggressive media: – Saltpeter from stone or concrete – Cement – Plaster – Acids – Alkali – Road salt – Aggressive paints or sealants – Aggressive sealants
Falling parts During dismantling, parts may fall and injure persons or damage property.
▶ Avoid temperatures greater than 50°C near the door.
5 .1 Instructed personnel
▶ Fix the cladding (e.g. with a forklift) before dismantling. Shaft
The door may only be operated by persons who have been instructed in its proper use. A person is considered to be instructed (EN 12453), if he / she has received instruction as to how to operate the door safely and has received permission from the owner to use the door system.
▶ Fix the shaft (e.g. with a forklift) before dismantling the operator.
Only inspect and maintain the door yourself if you are a qualified specialist (competent person according to EN 12635). In other words, you have the suitable training, specialist knowledge and practical experience to allow you to carry out inspection and maintenance correctly and safely. Observe all the applicable regulations governing work safety. In general, we recommend entrusting maintenance / inspection to the manufacturer‘s service department.
5 .2 Normal wear
The design of the door represents state-of-the-art technology. Pressure marks and abrasive wear are design- related and cannot be avoided.
Cladding (option)

The high-speed door is low-maintenance. In normal operating conditions, all the bearings, including the gears, are lubricated for life and are maintenance-free.
The control system is manufactured individually for each door ordered. The respectively applicable wiring diagram is deposited in the control cabinet.
6 .1 Maintenance intervals
▶ Add the wiring diagram and software description to these instructions. Each control cabinet has its own identification number. ▶ Always quote this number in the case of queries.
In the case of malfunctions, contact the Customer Service.
The operating voltage must be 230 V ± 5 % or 400 V ± 5 %. If the voltage deviates greatly from this, there may be problems with the operator power.
Use warm water together with a neutral, non-abrasive cleaning agent (household detergent, pH value 7, Isopropanol 99,9 %). To clean the surface, use only a soft cloth or window leather. Rinse off any dirt and dust particles with clear water.
6 .2 Wearing parts
If provided, the indicated maximum assumable cycles or door cycles apply to the following wearing parts:


Until 30.04.2017 Operator (tubular drive; 60 % ON time) 350.000 2 years
Unsuitable components Unsuitable components could overload the door construction. This could lead to serious injury.
From 01.05.2017 / V 4015 SEL Alu-R Operator (tubular drive; 60 % ON time) 1) 700.000 2 years
Only extend or convert this door system with the manufacturer‘s permission. Carrying out any structural alterations to the product without the manufacturer‘s permission renders the warranty and product liability null and void.
Radio crash switch battery – / – 2 years

Falling parts During dismantling, parts may fall and injure persons or damage property
UPS battery (RW doors) – / – 1 years
▶ Fix the cladding (e.g. with a forklift) before dismantling. Shaft
Curtain (V 3515 Iso + V 4015 Iso L) 150.000 2 years
Light grille / photocell – / – 2 years
▶ Fix the shaft (e.g. with a forklift) before dismantling the operator.
Only dismantle this door if you are qualified to do so (i.e. are a competent person in accordance with EN 12635). In other words, you have the suitable training, specialist
Operator power

knowledge and practical experience to allow you to dismantle the door correctly and safely. Observe all the applicable regulations governing work safety when dismantling the door.
To dismantle and dispose of the door: 1 . Open the door fully. 2 . Carefully roll up the door manually (emergency manual operation). 3 . Tape round the door curtain several times with strong adhesive tape (e.g. packing tape) to prevent it from unrolling. 4 . Drive a forklift truck with suitable pallet or supporting frame underneath the shaft, so that the shaft rests on the pallet or supporting frame. 5 . Release the fastenings securing the bearing and the operator. 6 . Lift the shaft or top part together with the operator off the support brackets. CAUTION The operator may slide off the barrel journal ▶ When letting the shaft or top part down, take care to keep it level. 7 . Dismantle the side guides or side elements and support brackets. 8 . Disassemble the door into component parts and dispose of them properly.