Bryantメーカー345MAVの使用説明書/サービス説明書
ページ先へ移動 of 12
USER’S INFORMA TION MANU AL MODEL 345MA V CONDENSING GAS FURN A CE — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHA T T O DO IF Y OU SMELL GAS: — Do not try to light any appliance.
INST ALLA TION D A T A Date Installed Dealer Name Address City State Zip T elephone FURNA CE Product No . Model No . Serial No . SPLIT -SYSTEM OUTDOOR UNIT: Product No .
3 FURN A CE COMPONENTS Burner sight glass for viewing burner flame. Burner assembly (inside). Operates with energy- saving inshot burners and hot surface ignitor for safe, dependable heating. Combustion-air intake connection (right or left side). Redundant gas valve.
4 IMPOR T ANT F A CTS Y our g as furnace uses air adjacent to the furnace for comb ustion and vents to the outside. Do not enclose it in an airtight room or seal it behind solid doors. It must hav e adequate air fl o w for ef fi cient combustion and safe v entilation.
5 STEPS FOR ST AR TING Y OUR FURN A CE 1. Set your room thermostat to the lo w- est temperature setting. (See Fig. 6.) 6 7 8 2. Close the e xternal manual gas v alve. (See Fig. 7.) 3. T urn off electrical supply to the fur - nace. (See Fig. 8.) 4. Remo ve the main furnace door .
6 12 .Set your thermostat to the temper- ature that satis fi es your comfort requirements. SUGGESTION: Setting the ther - mostat back a fe w de grees and compensating for the dif ference with warmer clothing can mak e a big dif ference in your fuel con- sumption on extremely cold days.
7 FIL TERING OUT TR OUBLE A dirty air fi lter will cause a loss of air fl ow in your duct system. When excessi ve loss of air fl ow occurs, the furnace may c ycle on its safety controls. If this condition is left unattended, the furnace will e v entu- ally lock out.
8 28 COMBUSTION AREA AND VENT SYSTEM V isually inspect the combustion area and vent system before each heating season. Make sure that all PVC pipes leading into the comb ustion area and vent are free from an y cracks and sags. Check the comb ustion-air intake adja- cent to the furnace for blockage.
9 32 33 7. Pour 1 quart of antifreeze into funnel/tube. Antifreeze should run through inducer housing, ov er fi ll condensate trap, and fl o w into open fi eld drain. (See Fig. 33.) 8. Remov e funnel and tube from inducer housing and replace drain connection cap and clamp.
10 vice, you will ha ve ready access to the information needed by your service representati ve. This furnace has an LED operation and fault code display to aid the installer , service technician, or home- o wner while installing or servicing the unit.
11.
Cancels: OM05-29 OM05-31 © 2000 Bryant Heating & Cooling Systems, 7310 W . Morris St., Indpls., IN 46231 12 Printed in U.S.A. Catalog No. 5334-509 10-00.
デバイスBryant 345MAVの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bryant 345MAVをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBryant 345MAVの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bryant 345MAVの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bryant 345MAVで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bryant 345MAVを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBryant 345MAVの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bryant 345MAVに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBryant 345MAVデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。