F or m No . PD S 502A. 24.1 HORIZONT AL INDOOR SINGLE P A CKA GE COOLING UNITS Single P ac kage Coo ling Un its F eaturing: • compac t design • flexibili ty • eas y main tena nce • high qu ali.
2 T ABLE OF CONTENTS Pa g e F eatures/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Model Nu mber Nome nclature . . . . . . . . . . . . . . . . . . . . . . . . . 2 ARI Capacit y Ratings . . . . . . . . . . . . . . . . .
3 PHYSICAL D A T A LEGEND *Shipping weights include base unit plus packaging. † If components are to be split, additional refrigerant will be needed.
4 FIELD-INST ALLED A CCESSORIES Thermo stat and Subbase — Attract i v e wall-mo unted 24-v access or y provi des pr eci se te mperat ure c ontr ol. Auto matic and Manu al changeo ver mo dels av ailab le. A thermostat s ubbase is av ailab le that works w ith Cycle-L OC ™ circuitr y .
5 B ASE UNI T DIMENSION S DIMENSIONS (ft-in.) UNIT 502A ABCDE 024 2-5 2-1 5 / 8 1- 5 3 / 4 1-2 1-1 036 2-4 3 / 4 2-2 1- 5 3 / 4 1-2 1-1 048 2-5 2-3 1-11 5 / 8 1-8 7 / 8 1-7 7 / 8 060 2-4 3 / 4 2-2 3 /.
6 SELECTION PROCEDURE (with e xample) I DETERMINE COO LING REQUIREMENTS A T DESIGN CONDITIONS. Given: Gross C ooling Capacity Required (TC) . . . . . . . . . . . . . . . . . . . . . . . . . 39,00 0 Btuh Sensib le Heat Capaci ty (SHC) . . . . . . . . .
7 PERFORMANCE D A T A (cont) GROSS COOLING CAP A CITIES (cont) LEGEND NO TES: 1. Perf or m ance based on nomin al conden ser airflow l isted in physical da ta table on page 3 . 2. SHC is ba sed on 80 F db te mperature of air e nteri ng the co il. Below 80 F db, subtract (corr factor x cfm) from SHC.
8 PERFORMANCE D A T A (cont) BEL T DRIVE EV APORA T OR F AN PERFORMANCE (Spec ial Or der Only , Pricing an d or dering on related pri ce pages.) LEGEND NO TE: Pulley setting must be adjusted to limit cfm to 450 cfm/ton maximum. Unit operation bey ond that limit may result in blo w-off and condensate problems .
9 CONTR OLS OPERA TING SEQUENCE Cooling 1. The r mosta t call s f or co oling . a. Indoor (e v aporator) f an rela y is energiz ed and starts e vap orato r f an. b . Compr essor contact or is energiz ed to star t compre ssor and conde nser fa n (up to a 5-min ute dela y on single- phase u nits).
10 ELECTRICAL D A T A (cont) ELECTRIC HEA TER ST A TIC PRESSURE DR O P (in. wg) NO TE: Abov e el ectric he aters are not UL or CSA listed f or use with optional hi gh-static ev apora tor-f an motor (048, 060 units only).
11 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator C — Contactor Compressor CAP — Capacitor CB — Circuit Breaker CC — Cooling Com pensator CDT — Compressor Disc.
12 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator C — Contactor Compressor CAP — Capacitor CB — Circuit Breaker CC — Cooling Com pensator CDT — Compressor Disc.
13 TYPICAL WIRING SCHEMA TICS (cont) LEGEND AHA — Adjustab le Heat Anticipator BKR W/A T — Breaks wit h Amp T urns C — Contactor Compressor CC — Cooling Com pensator CLO — Comp ressor L ocko.
14 TYPICAL PIPING AND WIRING APPLICA TION D A T A OUTDOOR-AIR TEMPERA T URE OPERA TING LIMIT S (F) Field Splitting Ins tructions — If c omp onen ts ar e s plit , ma xi- mum length of ref rigerant tubing to be us ed is 50 ft, as suming compon ents are ins talled in same hor iz ontal pl ane.
15 GUIDE S PECIFICA TIONS INDOOR P A CKA GED UNIT HV AC GUIDE SPECIFICA TIONS — SECTION 157 87 SIZE RANGE: 2 T O 5 T ONS, NOMINAL BR Y ANT MODEL NUMBER: 502A PA R T 1 — GENERAL 1.01 SYSTEM DESCRIPTION Indoor mo unted, electrically c ontrolled pac kaged horizon- tal coo ling unit uti lizing a her metic typ e scroll compre ssor .
Copyright 2001 Bryant Heating & Cooling Systems Printed in U.S . A. 1-01 Catalog No. 5250-200 SPECIFICATIONS SUBJE CT TO CHANGE WITHOUT NOTICE UNIT MUST BE INST ALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS GUIDE SPECIFICA TIONS (cont) 3.
デバイスBryant 502Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bryant 502Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBryant 502Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bryant 502Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bryant 502Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bryant 502Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBryant 502Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bryant 502Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBryant 502Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。