USER’S INFORMA TION MANU AL MODEL 340MA V , 350MA V , 352MA V , 355MA V CONDENSING GAS FURN A CE — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHA T T O DO IF YOU SMELL GAS: — Do not try to light any appliance.
INST ALLA TION D A T A Date Installed Dealer Name Address City State Zip T elephone FURNA CE Product No . Model No . Serial No . SPLIT -SYSTEM OUTDOOR UNIT: Product No .
3 FURN A CE COMPONENTS Combustion-air intake connection to ensure contaminant-free air (right or left side). Burner sight glass for viewing burner flame. Burner assembly (inside). Operates with energy- saving inshot burners and hot surface ignitor for safe, dependable heating.
4 IMPOR T ANT F A CTS Y our gas furnace uses air from outside the home for combustion and venting. It is not to be installed using in-house air . Therefore, both pipes must terminate outside the structure and must not be obstructed in any w ay .
5 a 8 9 10 2. Close the external manual g as v alve. (See Fig. 9.) 3. T urn of f electrical supply to the furnace. (See Fig. 10.) 4. Remov e the main furnace door . (See Fig. 11.) 5. Gas valve will ha ve EITHER a con- trol switch or control knob to turn OFF or ON.
6 16 17 18 SHUTTING DO WN Y OUR FURN A CE Should you need to shut do wn your furnace for service or maintenance, you will need to turn the furnace of f. 19 O P E N ® 20 The follo wing procedures must be follo wed: 1. Set your room thermostat to the lo west temperature setting.
7 BLO WER COMP AR TMENT a. Remo ve main furnace door . (See Fig. 23) b . Remove blo wer access panel. (See Fig. 24) NO TE: It will be necessary to remov e 2 screws • AIR FIL TER LOCA TED IN FIL- TER CABINET a. Remo ve fi lter cabinet door (See Fig.
8 29 30 COMBUSTION AREA AND VENT SYSTEM V isually inspect the combustion area and vent system before each heating season. Make sure that all PVC pipes leading into the comb ustion area and vent are free from an y cracks and sags. Also check the comb ustion-air intake and vent pipes on the outside of your home for blockage.
9 34 35 7. Pour 1 quart of antifreeze into funnel/tube. Antifreeze should run through inducer housing, over fi ll condensate trap, and fl ow into open fi eld drain. (See Fig. 35.) 8. Remov e funnel and tube from inducer housing and replace drain connection cap and clamp.
10 39 40 41 BEFORE Y OU REQUEST A SER VICE CALL If your furnace is not operating or not performing properly , you may sav e the expense of a service call by check- ing a fe w things yourself before calling for service. FOR INSUFFICIENT AIRFLOW : • Check for dirty air fi lter(s).
11 MODEL 340MA V AND 350MA V DIA GNOSTIC CHAR T (See Fig. 3.) NO TES: 1. Light on continuously means control has po wer and working properly . 2. The fault code is a 2-digit n umber . The fi rst digit is determined by the number of short fl ashes of the light and the second digit is determined by number of long fl ashes of the light.
Cancels: OM05-30 OM05-32 © 2001 Bryant Heating & Cooling Systems, 7310 W . Morris St., Indpls., IN 46231 12 Printed in U.S .A. Catalog No . 5335-202 3-01 MODEL 355MA V DIA GNOSTIC CHAR T (See Fig. 4.) NO TES: 1. Red light 1 on continuously means furnace is operating in emergency heat.
デバイスBryant CONDENSING GAS FURNACE 340MAVの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bryant CONDENSING GAS FURNACE 340MAVをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBryant CONDENSING GAS FURNACE 340MAVの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bryant CONDENSING GAS FURNACE 340MAVの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bryant CONDENSING GAS FURNACE 340MAVで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bryant CONDENSING GAS FURNACE 340MAVを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBryant CONDENSING GAS FURNACE 340MAVの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bryant CONDENSING GAS FURNACE 340MAVに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBryant CONDENSING GAS FURNACE 340MAVデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。