Overview The CAN-ISO-2500 is a galvanic isolation device for use on CANBus networks in mobile or stationary applications. The device features 2500 V isolation between the HV and LV sides and supports CAN Baudrates of up to 1 Mbit/s. The CAN-ISO-2500 is available with M12 5-pin connector pigtails or M12 connectors directly on the case and features flange-style holes for mounting to a surface. The case is rated IP54 (protection against dust and splashing water) for mounting in harsh mobile equipment environments.

Features

  • Up to 2500 V Galvanic Isolation
  • Up to 1 Mbit/s data rate
  • Automatically adjusts to CAN baud-rates, no need to set data rate
  • Wide input voltage range of 6-28v DC
  • IP54 standard rating (IP65 or IP67 available on request)

Applications CAN Bus data transmission is ubiquitous on vehicles and mobile equipment and is a popular protocol for industrial communications applications. Many CAN data busses are powered by a single power supply; however, on busses with different power supplies voltage transients can travel across the data bus causing signal integrity problems and possibly destroy CAN connected devices. Alternately, high- precision data acquisition systems may require isolation from the main power supply to ensure measurement accuracy. Either of these scenarios will require high-quality galvanic isolation for proper operation. Multiple Power Supplies on single CAN Network For scenarios where CAN devices are connected to different power supplies (see Figure 1) voltage differences on the CAN network can cause data transmission issues and even damage components. The CAN-ISO-2500 can be used to isolate different components on the bus and eliminate the possibility of damage caused by voltage differences.

GALVANIC CAN Bus Isolation Device (CAN-ISO-2500) — Features diagram (page 2)
図 2 · Features
Figure 1CAN Circuit with Galvanic Isolation Requirement
Page 3 of the GALVANIC CAN Bus Isolation Device (CAN-ISO-2500) user manual — Specifications Physical
3ページ · クリックして拡大
3ページ

Specifications Physical

DimensionMeasure (pigtails) (Figure 2)Measure (Bulkhead) (Figure 3) Width5.8 cm5.8 cm Length13 cm (measured from strain reliefs) 8.6 cm (case)8.6 cm Height3 cm4.2 cm (no connector) Weight110 g87 g Cable Length15 cmOn Case IP RatingIP54 (IP67 available on request)IP54 (IP67 available on request) Flange Mounting HolesRectangular pattern 4x 5mm through holes, countersunk (see Figure 4)Rectangular pattern 4x 5mm through holes, countersunk (see Figure 4)
Figure 2Pigtail Option
Page 4 of the GALVANIC CAN Bus Isolation Device (CAN-ISO-2500) user manual — Specifications Physical
4ページ · クリックして拡大
4ページ
GALVANIC CAN Bus Isolation Device (CAN-ISO-2500) — Specifications Physical diagram (page 4)
図 3 · Specifications Physical
Figure 3Bulkhead Option
GALVANIC CAN Bus Isolation Device (CAN-ISO-2500) — Specifications Physical diagram (page 4)
図 4 · Specifications Physical
Figure 4Flange Mounting Pattern – mm [in]
Page 5 of the GALVANIC CAN Bus Isolation Device (CAN-ISO-2500) user manual — Specifications Physical
5ページ · クリックして拡大
5ページ
GALVANIC CAN Bus Isolation Device (CAN-ISO-2500) — Specifications Physical diagram (page 5)
図 5 · Specifications Physical
SpecMinMaxNote Input Voltage7 V28 V CAN Baudrate100 Kbit/s1 Mbit/s Isolation Between HV and LV2.5 kVTested 1s Propagation Delay150 ns
  • Reverse Polarity protected Installation Considerations The CAN-ISO-2500 adds 150 ns of propagation delay to the CAN data signals, see table below for CAN data bus lengths with CAN Isolator installed. For proper operation ensure maximum CAN bus length does not exceed the following values with one CAN-ISO-2500 installed.

Bit Rate Typical Max Bus Length Recommended Max Bus length with CAN-ISO-2500 1 Mbit/s 40 m 10 m 500 kbit/s 110 m 80 m 250 kbit/s 240 m 210 m 125 kbit/s 500 m 470 m 50 kbit/s 1300 m 1270 m Bitrates below 50 kbit/s the propagation delay is negligible Tests and Certifications RF Emissions: Tested per CISPR22 Edition 5.2 2006-03 Class A EMC: Tested per IEC 61000-4-2 Edition 3.2 2010-04 Level 2 ESD Immunity: Tested per IEC 61000-4-2 Edition 2.0 2008-12 Class 2 Galvanic Isolation: tested 2.5kV between HV and LV connector pins

GALVANIC CAN Bus Isolation Device (CAN-ISO-2500) — Specifications Physical diagram (page 5)
図 6 · Specifications Physical

Electrical

Page 6 of the GALVANIC CAN Bus Isolation Device (CAN-ISO-2500) user manual — Troubleshooting No CAN data
6ページ · クリックして拡大
6ページ

Wiring and Connections The CAN-ISO-2500 comes standard with two waterproof M12 barrel type connectors. The CAN-ISO-2500 contains a 120 Ohm termination resistor on both the input and output and can be placed anywhere in the middle of an existing CAN data bus. Pinouts are consistent across all M12 connector types.

GALVANIC CAN Bus Isolation Device (CAN-ISO-2500) — Troubleshooting No CAN data diagram (page 6)
図 7 · Troubleshooting No CAN data
PinLV SideHV Side 1GND (Optional)GND (Optional) 2VinNC 3GNDGND 4CAN HighCAN High 5CAN LowCAN Low
GALVANIC CAN Bus Isolation Device (CAN-ISO-2500) — Troubleshooting No CAN data diagram (page 6)
図 8 · Troubleshooting No CAN data
Part NumberStyleSupplier 7000-12961-0000000M12 Female, straightAutomationDirect 7000-12761-0000000M12 Male, StraightAutomationDirect

Troubleshooting No CAN data

  • Check Input Voltage (7-30v DC)
  • Confirm CAN HV/LV wiring pin out
  • Check power status LED inside cover

GALVANIC CAN Bus Isolation Device (CAN-ISO-2500)について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
GALVANIC CAN Bus Isolation Device (CAN-ISO-2500)に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

GALVANIC CAN Bus Isolation Device (CAN-ISO-2500) 取扱説明書(PDF)

6 ページ·179 KB·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…