BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 www .bunnomatic.com OPERA TING & SER VICE MANU AL AFPO-2 AFPO-2 SL AFPO-3.
2 INTRODUCTION This equipment supplies a liquid concentrate mixed with water at various ratios to the hoppers on the CDS-2 or CDS-3 dispensers. It is for indoor use only on a sturdy counter or shelf.
3 ELECTRICAL REQUIREMENTS CAUTION - The dispenser must be disconnected from the power sour ce until specified in Initial Set-Up. The 120 volt version of this dispenser has an attached cordset and requires 2-wire, grounded ser vice rated 120 volts ac, 15 amp, single phase, 60 Hz.
4 28791 040501 5. Connect one end of input hoses to the auto refill box and the other end to the product container. Product container connectors (BIB) are not supplied. Install your own interface. 6. Connect water line to auto refill box. A minimum of 20 psi (138 kPa) is required.
5 Mix ratio (water/flavor) Time for FLAVOR OUTPUT (1/2 cup) Time for WATER OUTPUT (1 cup) 1+1 assume 20 sec. or obtain time per note below 40 sec. or 2 times flavor output time 2+1 assume 20 sec. or obtain time per note below 20 sec. or equal to flavor output time 3+1 assume 20 sec.
6 OPERA TING CONTROLS A. MAIN POWER ON/OFF The main power ON/OFF switch is located on the right of the front panel just above the power cord. B. REFILL CIRCUIT ON/OFF The refill circuit ON/OFF switches are located on the right of the front panel just above the main power switch.
7 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.
8 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE 6. Main ON/OFF switch 7. Probe box LOW/OFF/HIGH switches 8. Circuit board 9. Vacuum switch 10. Vacuum/Supply pump 11. Pump (flavor) start switches 1. No water 2. Needle valve 3. Solenoids 1. Motor overheat REMEDY Refer to Service - Main ON/OFF Switch for testing procedure.
9 SERVICE This section provides procedures for testing and replacing various major components used in this dispenser should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem.
10 SERVICE CIRCUIT BOARD OFF OFF O N OFF OFF O N OFF OFF O N OFF OFF O N FIG. 2 CIRCUIT BOARD P1520 Location: The circuit board is located inside the autofill box, mounted on the right side of the solenoid mounting bracket under the switch panel. Test Procedure: 1.
11 SERVICE Location: The fuse holder is located on the lower right front of the autofill box just to the left of the power cord. Test Procedure: 1. Disconnect the dispenser from the power source. 2. Remove cap and fuse from fuse holder. 3. Remove fuse from the cap.
12 P1522 FIG. 7 MAIN ON/OFF SWITCH TERMINALS BLK from Fuse Holder BLK to Solenoid (Water) Switch #2 AFPO-2 & 3 MAIN ON/OFF SWITCH F L A V O R I N P U T 1 2 W A T E R I N P U T R E F I L L M A I N .
13 Probe Boxes: 1. Disconnect the signal cable from the probe boxes. 2. Remove probe box from CDS hopper. 3. Place the switch on the probe box in the “HIGH” position. 4. Check the resistance across the box cable pins, see Fig. 10. 5. With the probe box switch in the “LOW” position check the resistance across the pins, refer to Fig.
14 F L A V O R I N P U T 1 2 W A T E R I N P U T R E F I L L M A I N P O W E R 2 1 1 2 3 3 3 F L A V O R O U T P U T F L A V O R O U T P U T W A T E R O U T P U T F L A V O R O U T P U T W A T E R O U T P U T W A T E R O U T P U T SERVICE (cont.
15 SERVICE (cont.) REFILL SWITCHES FIG. 14 REFILL SWITCHES Location: The refill switches are located on the upper right front of the autofill box. T est Procedures: 1. Disconnect the dispenser from the power source. 2. Disconnect the two white/red, brown/black or red/ black wires from the switch terminals.
16 SERVICE (cont.) SOLENOIDS FIG. 16 SOLENOIDS Location: The solenoids are located inside the autofill box. T est Procedure: 1. Disconnect the dispenser from the power source. 2. Disconnect the white/violet, violet or blue wire and the white wire from the solenoid.
17 SERVICE (cont.) SOLENOID (W A TER) ON/OFF SWITCHES F L A V O R I N P U T 1 2 W A T E R I N P U T R E F I L L M A I N P O W E R 2 1 1 2 3 3 3 F L A V O R O U T P U T F L A V O R O U T P U T W A T E R O U T P U T F L A V O R O U T P U T W A T E R O U T P U T W A T E R O U T P U T FIG.
18 F L A V O R I N P U T 1 2 W A T E R I N P U T R E F I L L M A I N P O W E R 2 1 1 2 3 3 3 F L A V O R O U T P U T F L A V O R O U T P U T W A T E R O U T P U T F L A V O R O U T P U T W A T E R O U T P U T W A T E R O U T P U T SERVICE (cont.) TEST/OPERA TE ON/OFF SWITCH FIG.
19 SERVICE (cont.) V ACUUM/SUPPL Y PUMP ASSEMBL Y FIG. 22 V ACUUM/SUPPL Y PUMP ASSEMBL Y P1521 Location: The vacuum/supply pumps are located inside the autofill box. T est Procedure: 1. Disconnect the dispenser from the power source. 2. Disconnect the white wire from the pump lead and the yellow, orange or red wire from the other lead.
20 SERVICE (cont.) V ACUUM/SUPPL Y PUMP TUBE INST ALLA TION FIG. 24 TUBING START POSITION P1542 ROLLERS PUMP HEAD TUBING KEY ENTRY PORT EXIT PORT FIG. 25 TUBING LOADED ROTOR ROTOR SHAFT P1541 28791 040501 2. Separate the two halves of the pump and carefully remove the tubing from within.
21 V ACUUM SWITCHES FIG. 26 V ACUUM SWITCHES Location: The vacuum switches are located inside autofill box, mounted on the left side of the solenoid mount- ing bracket just below the needle valves. Test Procedure: 1. Disconnect the dispenser from the power source.
22 F L A V O R IN P U T 1 2 W A T E R IN P U T F L A V O R O U T P U T F L A V O R O U T P U T W A T E R O U T P U T W A T E R O U T P U T R E F IL L M A IN P O W E R 2 1 1 2 BUNN ® M o v i n g P a r t s . D o n o t o p e r a t e u n i t w i t h t h i s p a n e l r e m o v e d .
23 GRN SOL #1 SOL #2 PUMP #1 PUMP #2 10 AMP MAIN ON/OFF SWITCH REFILL ON/OFF SWITCH #1 REFILL ON/OFF SWITCH #2 J4-1 2 3 4 5 6 7 8 9 J4-10 C I R C U I T B O A R D L1 N BLK BLK BLK B L K B L K B L K SOL.
24 GRN SOL #1 SOL #2 PUMP #1 PUMP #2 10 AMP MAIN ON/OFF SWITCH REFILL ON/OFF SWITCH #1 REFILL ON/OFF SWITCH #3 REFILL ON/OFF SWITCH #2 J4-1 2 3 4 5 6 7 8 9 J4-10 C I R C U I T B O A R D L1 N BLK BLK B.
25 28791 011500 GRN SOL #1 SOL #2 PUMP #1 PUMP #2 10 AMP MAIN ON/OFF SWITCH REFILL ON/OFF SWITCH #1 REFILL ON/OFF SWITCH #2 J4-1 2 3 4 5 6 7 8 9 J4-10 C I R C U I T B O A R D L1 L2 BLK BLK BLK B L K B.
デバイスBunn AFPO-2 SLの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bunn AFPO-2 SLをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBunn AFPO-2 SLの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bunn AFPO-2 SLの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bunn AFPO-2 SLで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bunn AFPO-2 SLを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBunn AFPO-2 SLの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bunn AFPO-2 SLに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBunn AFPO-2 SLデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。