BUNN-O-MA TIC CORPORA TION T W F -E Z POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 TELEPHONE: (217) 529-6601 FAX: (217) 529-6644 29466.0000C 8/00 © 1999 Bunn-O-Matic Corporation OPER A T I NG & SE R V I CE M AN U A L B U N N ® DISCONTINUED VERSION The information in this manual is no longer current.
Page 2 CONTENTS Introduction .............................................................. 2 Warranty ................................................................... 2 User Notices ............................................................. 3 Electrical Requirements .
Page 3 #00831.0000 #00656.0000 #03408.0000 #03409.0000 USER NOTICES Carefully read and follow all notices on the equipment and in this manual. They were written for your protec- tion. All notices on the equipment should be kept in good condition. Replace any unreadable or damaged labels.
Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power sour ce until specified in Initial Set-Up. 120V model brewers require 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. Proceed as follows: Electrical Hook-Up CAUTION – Improper electrical installation will damage electronic components.
Page 5 INITIAL SET -UP 1. Insert the funnel (empty) into the funnel rails. 2. Place an empty tea dispenser on the brewer base. Be prepared to empty the dispenser a few times. 3. Plug in the brewer , place the TEA/OFF/COFFEE switch in the “ COFFEE ” position, and momentarily press the start switch.
Page 6 OPERA TING CONTROLS A. TEA/OFF/COFFEE Switch TEA- Placing the switch in the full left position allows the start switch to activate a timed brew cycle for a 0.
Page 7 TWF-EZ ADJUSTMENTS & OPTIONAL SETTINGS Adjusting Brew V olumes BREW VOLUME SET -UP: Use the following steps when setting up the brewer for the first time.
Page 8 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Service Department.
Page 9 TROUBLESHOOTING (cont.) BREW CIRCUIT PROBLEM PROBABLE CAUSE REMEDY Ready Light Flashing Brew cycle will not start 1. Brewer has shut down due to malfunction. 1. No water 2. No power or incorrect voltage to the brewer 3. TEA/OFF/COFFEE Switch 4.
Page 10 TROUBLESHOOTING (cont.) BREW CIRCUIT PROBLEM PROBABLE CAUSE REMEDY Refer to Adjustments and Optional Settings to set brew volume. See page 7. Using a stop watch or sec- ond hand, time the length of the brew cycle. Record this time inside the top lid.
Page 11 TROUBLESHOOTING (cont.) BREW CIRCUIT PROBLEM PROBABLE CAUSE REMEDY Dripping from sprayhead Weak beverage Drip out time too long 1. Lime build up 2. Brew Solenoid V alves 1. Sprayhead 2. Water temperatur e 3. Filter type 4. Funnel loading 1. Funnel Tip (T ea brewing) Inspect the tank assembly for ex- cessive lime deposits.
Page 12 TROUBLESHOOTING (cont.) BREW CIRCUIT PROBLEM PROBABLE CAUSE REMEDY Dry tea leaves or coffee grounds re- main in the funnel 1. Sprayhead 2. Funnel loading Make sure sprayhead is present and holes are clear and unobstructed. There should be seven separate streams of water coming out of the sprayhead.
Page 13 TROUBLESHOOTING (cont.) HEATING CIRCUIT PROBLEM PROBABLE CAUSE REMEDY 29466 082200 W ater does not heat to proper temperature IMPORT ANT : Make sure no tem- perature tests are taken before the ready light is "ON". T ank tempera- ture must be stabilized before read- ings are taken.
Page 14 DIAGNOSTICS Intermittent flashing of the READY indicator indicates that a fault exists. Count the number of flashes between pauses and use this chart as a guide to investigating the fault.
Page 15 SERVICE This section provides procedures for testing and replacing various major components used in this brewer should service become necessar y .
Page 16 Location: Viewing the brewer from the rear the hot coffee brew solenoid valve is mounted on the left side of the mounting bracket. Test Procedures: 1. Disconnect the brewer from the power sour ce. 2. Disconnect the white/red and white wires from the hot coffee solenoid valve.
Page 17 P1960.60 FIG. 4 ICED TEA BREW SOLENOID V AL VE Location: Viewing the brewer from the rear the iced tea brew solenoid valve is mounted in the center of the mount- ing bracket. Test Procedures: 1. Disconnect the brewer from the power sour ce. 2.
Page 18 SERVICE (cont.) DILUTION SOLENOID V AL VE FIG. 6 DILUTION SOLENOID V AL VE P1960.60 Location: Viewing the brewer from the rear the dilution so- lenoid is mounted on the right side of the solenoid mounting bracket. T est Pr ocedure: 1. Disconnect the brewer from the power sour ce.
Page 19 SERVICE (cont.) LIMIT THERMOST A T FIG. 8 LIMIT THERMOST A T P1960.60 Location: The limit thermostat is located inside the hood on the tank lid. T est Pr ocedure: 1. Disconnect the brewer from the power sour ce and remove the blue wire from the limit thermostat.
Page 20 FIG.11 TEA/OFF/COFFEE SWITCH TERMINALS P1525 SERVICE (cont.) TEA/OFF/COFFEE SWITCH FIG. 10 TEA/OFF/COFFEE SWITCH P1808.40 Location: The TEA/OFF/COFFEE switch is located in the front of the hood, above and to the left of the brew funnel. T est Pr ocedure: 1.
Page 21 SERVICE (cont.) ST ART SWITCH FIG. 12 ST ART SWITCH P1808.40 Location: The start switch is located in the front of the hood, above and to the right of the brew funnel. T est Pr ocedure: 1. Disconnect the brewer from the power sour ce. 2. Remove white/yellow and white/orange wires from the Start switch.
Page 22 FIG. 14 T ANK HEA TER Location: The tank heater is located inside the tank and se- cured to the tank lid. T est Pr ocedures: 1. Disconnect the brewer from the power supply . 2. With a voltmeter , check the voltage across the black and white wires.
Page 23 SERVICE (cont.) TEMPERA TURE PROBE FIG. 16 TEMPERA TURE PROBE P1960.60 Location: The temperature probe is located on the tank lid, to the rear and left of the sprayhead tube. T est Pr ocedures: 1. Disconnect the brewer from the power sour ce. 2.
Page 24 SERVICE (cont.) THERMAL FUSE FIG. 18 THERMAL FUSE P1960.60 Location: The thermal fuse is located inside the hood con- nected to the right tank heater terminal. T est Pr ocedures: 1. Disconnect the brewer from the power sour ce. 2. Disconnect the thermal fuse from the tank heater terminal and the limit thermostat.
Page 25 SERVICE (cont.) CONTROL BOARD FIG. 20 CONTROL BOARD P1960.50 TRM1 T R M 2 J 6 J 7 J3 J 1 J4 J2 J 5 Location: The Control Board is located inside the hood on the right front behind the Start switch. T est Pr ocedure: The test procedures for the control board will vary depending upon the problems experienced by the brewer .
Page 26 29466 082200.
デバイスBunn twf-ezの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bunn twf-ezをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBunn twf-ezの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bunn twf-ezの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bunn twf-ezで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bunn twf-ezを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBunn twf-ezの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bunn twf-ezに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBunn twf-ezデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。