Section 61245211L1-5, Issue 1 61245211L1-5A 1 PRACTICES SINGLE-WIDE FT1 REPEA TER INST ALLA TION/MAINTENANCE Contents 1. General ................................................................................ 1 2. Installation .......................
2 Section 61245211L1-5, Issue 1 61245211L1-5A The ADTRAN Single-Wide FT1 Repeater provides three faceplate LEDs which indicate signal quality, error conditions, and loopback status. See Table A for a description of the LED indicators. Operating power is derived from an ADTRAN FT1 DP, independent of line impedance or wire gauge.
Section 61245211L1-5, Issue 1 61245211L1-5A 3 2. INSTALLATION CAUTION This equipment contains static-sensitive components. Be sure to follow proper electrostatic discharge procedures before handling or installing the equipment.
4 Section 61245211L1-5, Issue 1 61245211L1-5A 4. MAINTENANCE The ADTRAN Single-Wide FT1 Repeater requires no routine maintenance. In case of equipment malfunction, perform an in-band loopback from the central office (CO), as described in Appendix A of this practice.
Section 61245211L1-5, Issue 1 61245211L1-5A 5 Table C. Loop Insertion Loss Data Frequency Maximum Loss (Hz) (dB) 3000 ...................... 12.0 10,000 ...................... 15.0 50,000 ...................... 25.5 100,000 ...................... 30.0 150,000 .
6 Section 61245211L1-5, Issue 1 61245211L1-5A Loop Interface Modulation Type .................................. 2B1Q Mode ..................................................... Full Duplex, Echo Cancelling Number of Pairs ..............................
A-1 Section 61245211L1-5, Issue 1 61245211L1-5A APPENDIX A FT1 LOOPBACKS 1. GENERAL This Appendix is an overall reference to the loopback capabilities of the ADTRAN Fractional T1 system. Included in the Appendix is a description of the FT1 loopbacks and the methods for activating the FT1 loopbacks.
A-2 Section 61245211L1-5, Issue 1 61245211L1-5A There is one loopback available to the FT1 Repeater. The FT1 Repeater Network loopback is a digital loopback toward the CO as shown in Figure A-4. The loopback is initiated by the DDS latching loopback code for NEI Position 1 (N1000001).
A-3 Section 61245211L1-5, Issue 1 61245211L1-5A 3. LOOPBACK ACTIVATION AND DEACTIVATION This section describes loopback activation and deactivation methods for the ADTRAN Fractional T1 system. Loopback activation and deactivation is controlled with the push-button located on the front panel, through craft interface, or latching loopback codes.
A-4 Section 61245211L1-5, Issue 1 61245211L1-5A 4. LOOP-UP STATE In the loop-up state, the active FT1 loopback will provide a continuous loop for the FT1 bandwidth. The data flow is continuously monitored for the loop deactivation commands to deactivate the loopbacks.
デバイスADTRAN FT1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
ADTRAN FT1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはADTRAN FT1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。ADTRAN FT1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。ADTRAN FT1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
ADTRAN FT1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はADTRAN FT1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、ADTRAN FT1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちADTRAN FT1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。