C ONSTRUCTION M ASTER ® P RO ADV ANCED CONSTRUCTION - MA TH CALCULAT OR Model 4065 v3.1 P ock et R ef erence Guide.
C ONSTRUCTION M ASTER ® P RO V 3.1 The Construction Master Pro calculators help you save time, cut costly errors and build like a pro! Quickly Solve: • Metric Dimensional Problems and Conversions .
T ABLE OF CONTENTS NOTE TO METRIC USERS .................... 1 KEY DEFINITIONS ................................. 4 Basic Function Keys ............................ 4 Unit Keys ............................................. 5 Length, Width and Height Keys .
Concrete Footings ............................. 20 Concrete V olume for Driveway .......... 20 Converting D:M:S .............................. 21 Polygon – Brick Paving ..................... 21 Squaring-Up a Foundation ................ 22 Studs ....
P OCKET R EFERENCE G UIDE — 1 NOTE TO METRIC USERS The factory-set Stored V alues and Preferences for the Construction Master Pro are set in imperial values.
P OCKET R EFERENCE G UIDE — 2 (Cont'd) STORED V ALUES DEF AUL T V ALUE Weight per V olume 1500 K G Per CU M Block Area 80000 SQ MM Block Length 400 MM Footing Area 170000 MM T o change the default values, enter the new value, then press ß and the key for the value being changed.
P OCKET R EFERENCE G UIDE — 3 4. Convert On-Center Spacing to 400 mm: 4 0 0 Ç 9 ß 5 OC STORED 400 MM 5. Convert Weight Per V olume to 1500 kG per cu m: 1 5 0 0 ß 0 (press 0 until desired value is displayed) STORED 1500 KG PER CU M 6. Convert Block Area to 80000 sq mm: 8 0 0 0 0 Ç 9 9 ß 4 B-AR STORED 80000 SQ MM 7.
P OCKET R EFERENCE G UIDE — 4 KEY DEFINITIONS Basic Function Keys + – x Arithmetic operation keys. ÷ = % Four-function (+, –, x, ÷) percent key . 0 – 9 Keys used for entering and • numbers. O Off Key — T urns all power off, clearing all non-permanent registers.
P OCKET R EFERENCE G UIDE — 5 Unit Keys y Y ards f Feet i Inch / Fraction Bar m Meters Ç 7 Centimeters Ç 9 Millimeters Ç 2 Acres Length, Width and Height Keys l Enters length for calculation of area or volume. W Calculates area, square-up and perimeter .
P OCKET R EFERENCE G UIDE — 6 Ç a Radius — Enters or calculates circle radius. Construction Project Keys Ç l Blocks/Bricks — Finds the number of blocks or bricks for a given area and stored block/ brick size. ß 4 — Stores block or brick size.
P OCKET R EFERENCE G UIDE — 7 Ç W Footing — Finds quantity of concrete, based on entered wall length and stored footing area. ß 6 — Stores footing area. Ç d Roof — Calculates roof area, number of roof squares and bundles, and number of 4 x 8 sheets based on an entered or calculated plan area.
P OCKET R EFERENCE G UIDE — 8 r Enters or calculates the vertical leg of a right triangle. Ç r Rake-Wall — Finds the stud sizes based on entered right triangle values. R Enters or calculates the hori- zontal leg of a right triangle. d Diagonal — Enters or calculates the Diagonal leg, or Common rafter .
P OCKET R EFERENCE G UIDE — 9 Stair Layout Key s Given rise and/or run and stored variables, calculates or displays: Press Result 1 Riser Height 2 Number of Risers 3 Riser Overage/ Underage 4 T read.
P OCKET R EFERENCE G UIDE — 10 Ç s Riser Limited — Recalculates Riser Height and other stair values if you’re lim- ited by local code. The calcu- lated Riser Height will never exceed the stored Desired Riser Height. Customizable Stair Settings ß 7 Stores Desired Riser Height.
P OCKET R EFERENCE G UIDE — 1 1 Ç • Converts between D:M:S and Decimal Degrees. Ç % x 2 Ç B ( ) Square Root Ç / Exponential Notation (x10 y ) Ç 0 T otal Cost (based on entry of per unit cost).
P OCKET R EFERENCE G UIDE — 12 ENTERING DIMENSIONS Entering Linear Dimensions Examples of entering Linear Dimensions: DIMENSION KEYSTROKE Clear calculator o 17.
P OCKET R EFERENCE G UIDE — 13 KEYSTROKE DISPLA Y o o 0. Enter numeric value and press desired unit key three times to label value as “Cubic:” 1 0 0 Ç 9 9 9 100 CU MM Note: If you pass the desired dimensional for- mat, keep on pressing the dimensional unit key until the desired result is displayed again.
P OCKET R EFERENCE G UIDE — 14 Rectangular Area and V olume Find the area and volume: • Length: 6200 mm • Width: 3500 mm • Height: 450 mm KEYSTROKE DISPLA Y 6 2 0 0 Ç 9 l 3 5 0 0 Ç 9 W W AREA 21.7 SQ M 4 5 0 Ç 9 h h VOL 9.765 CU M Entering Square and Cubic and Adding a W aste Allowance Add a 10% waste allowance to 5200 sq mm.
P OCKET R EFERENCE G UIDE — 15 Using Multi-Function h Key Find the volume, wall area and total room area of a room measuring 4500 mm x 5500 mm. The room is 2500 mm high. KEYSTROKE DISPLA Y o o 0. 4 5 0 0 Ç 9 l LNTH 4500. MM 5 5 0 0 Ç 9 W WDTH 5500.
P OCKET R EFERENCE G UIDE — 16 Linear Conversions Convert 3200 mm to other dimensions: KEYSTROKE DISPLA Y 3 2 0 0 Ç 9 3200. MM Ç 7 320. CM Ç m 3.200 M Ç f * 10 FEET 6 INCH Ç i * 126 INCH Ç y 3.5 YD *Repeated presses of f or i will toggle between Feet-Inch-Fractions and Decimal Feet or Inches.
P OCKET R EFERENCE G UIDE — 17 Board Feet and Cost Find the total Board Feet for the follow- ing boards: 2 x 4 x 16, 2 x 10 x 18 and 2 x 12 x 20. What is the total cost at $275 per MBM? KEYSTROKE DISPLA Y o o 0. 2 x 4 x 1 6 Ç 8 μ BDFT 10.66667 M 2 x 1 0 x 1 8 Ç 8 μ BDFT 30.
P OCKET R EFERENCE G UIDE — 18 Circle/Arc Properties Find Arc properties given a 1500 mm diameter and an Arc length of 900 mm: KEYSTROKE DISPLA Y 1. Enter Circle diameter and Arc length: o o 0. 1 5 0 0 Ç 9 C DIA 1500. MM 9 0 0 Ç 9 a ARC 900. MM 2.
P OCKET R EFERENCE G UIDE — 19 KEYSTROKE DISPLA Y o o 0. 3 8 ß Â SPRG STORED 38.00° 6 0 Â MITR 46.84° Â BEVL 43.03° Â SPRG STORED 38.00° Â CRNR 60.
P OCKET R EFERENCE G UIDE — 20 Concrete Footings Find the volume of concrete required for an 200 mm x 400 mm footing that measures 30 m in length: KEYSTROKE DISPLA Y o o 0. 2 0 0 Ç 9 x 4 0 0 Ç 9 = 80000. SQ MM ß 6 F-AR STORED 80000. SQ MM 3 0 m Ç W (Footing) FTG 2.
P OCKET R EFERENCE G UIDE — 21 Converting D:M:S Convert 23° 42’ 39” to decimal degrees: KEYSTROKE DISPLA Y o o 0. 2 3 • 4 2 • 3 9 DMS 23.42.39 Ç • (dms deg) 23.71° Polygon — Brick Paving Find the Full Angle, Bi-sect Angle, Side Length, Perimeter and Area of a Polygon for paving a brick patio.
P OCKET R EFERENCE G UIDE — 22 Squaring-Up a Foundation Square-up a 4700 mm x 3100 mm foundation:* KEYSTROKE DISPLA Y o o 0. 4 7 0 0 Ç 9 l LNTH 4700. MM 3 1 0 0 Ç 9 W WDTH 3100. MM W W SQUP 5630. MM *Alternative Method Square-up a 4700 mm x 3100 mm foundation:* KEYSTROKE DISPLA Y o o 0.
P OCKET R EFERENCE G UIDE — 23 Studs Find the number of 400 mm On-center studs* required for a wall measuring 7600 mm in length: KEYSTROKE DISPLA Y o o 0. 7 6 0 0 Ç 9 Ç 5 (Studs) STUD 20. * If you are working with a number other than 400 mm On-center , change it via ß 5 (e.
P OCKET R EFERENCE G UIDE — 24 RIGHT ANGLE/FRAMING Pitch — Converting Roof Angle Find the % Grade, Slope and Pitch in mm if the roof angle is 30.25°: KEYSTROKE DISPLA Y o o 0. 3 0 • 2 5 p PTCH 30.25° p %GRD 58.31828 p SLP 0.583183 p Ç 9 PTCH 178.
P OCKET R EFERENCE G UIDE — 25 Common Rafter Length Find the point-to-point length of the Common rafter on a 175/300 mm pitched roof with a span of 8500 mm. What are the angle cuts? KEYSTROKE DISPLA Y 1. Enter Pitch: o o 0. 1 7 5 Ç 9 p PTCH 175. MM 2.
P OCKET R EFERENCE G UIDE — 26 Regular Hip/V alley and Jack Rafters A roof ’s Pitch is 255/300 mm and half the total span is 1800 mm. Find the lengths of the Common, Hip/V alley and Jack rafters. Also find the incremental jack adjustment and the cut angles.
P OCKET R EFERENCE G UIDE — 27 j JK 4 249. MM j JK 5 0. MM j PLMB 36.43° j LEVL 53.57° j CHK1 45.00° Irregular Hip/V alley A roof has a 225/300 mm Pitch, an irreg- ular Pitch of 200/300 mm, and half the span is 2000 mm. Solve the Hip/V alley length.
P OCKET R EFERENCE G UIDE — 28 Rake-W all – No Base Find each stud size in a Rake-Wall with a peak of 1000 mm, and a length of 1500 mm. Use 400 mm as your on-center spacing: KEYSTROKE DISPLA Y 1. Enter Rise and Run: o o 0. 1 0 0 0 Ç 9 r RISE 1000.
P OCKET R EFERENCE G UIDE — 29 Rake-W all – With Base Find each stud size in a Rake-Wall with a peak of 1200 mm, a length of 2400 mm, and a base of 1500 mm. Use 400 mm as your On-center spacing: KEYSTROKE DISPLA Y 1. Enter Rise and Run: o o 0. 1 2 0 0 Ç 9 r RISE 1200.
P OCKET R EFERENCE G UIDE — 30 ST AIRS Stairs — Given Rise and Run Y ou’re going to build a stairway that has a floor-to-floor height of 3100 mm, a run of 3800 mm, and a desired riser height of 200 mm (default). Find the stair values: KEYSTROKE DISPLA Y 1.
P OCKET R EFERENCE G UIDE — 31 Stairs — Given Rise Only Y ou’re building a stairway with a total rise of 3000 mm. Using the default riser height of 200 mm and tread width of 250 mm, find the stair values: KEYSTROKE DISPLA Y 1. Enter known Rise: o o 0.
P OCKET R EFERENCE G UIDE — 32 Stairs — Riser Limited Function Calculate stairs using the Riser Limited function, if you must limit the Riser Size to 200 mm: KEYSTROKE DISPLA Y 1. Enter Rise and Run: o o 0. 3 0 0 0 Ç 9 r RISE 3000. MM 3 8 0 0 Ç 9 R RUN 3800.
P OCKET R EFERENCE G UIDE — 33 DEF AUL T SETTINGS After a Clear All ( Ç x ), your calculator will return to the following settings: STORED V ALUES DEF AUL T V ALUE Desired Riser Height 7-1/2 INCH Desired T read Width 10 INCH Floor Height 10 INCH On-center Spacing 16 INCH Weight per V olume 1.
P OCKET R EFERENCE G UIDE — 34 (Cont’d) PREFERENCE SETTINGS DEF AUL T V ALUE Stairway Headroom 6 feet 8 inch Rake-W all Descending Arched W all Outside Jack Rafters Descending Irregular Jack Spacing OC-OC Exponent Off Meter Linear Display 0.000 Decimal Degree Display 0.
P OCKET R EFERENCE G UIDE — 35 REP AIR AND RETURN Return Guidelines: 1. Please read the Warranty in this User's Guide to determine if your Calculated Industries product remains under warranty before calling or returning any device for evaluation or repairs.
This equipment has been certified to comply with the limits for a Class B computing device, pursuant to Subpart J of Part 15 of FCC rules. Software copyrighted and licensed to Calculated Industries, Inc. by Construction Master T echnologies, LLC, 2008.
デバイスCalculated Industries 4065の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Calculated Industries 4065をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCalculated Industries 4065の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Calculated Industries 4065の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Calculated Industries 4065で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Calculated Industries 4065を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCalculated Industries 4065の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Calculated Industries 4065に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCalculated Industries 4065デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。