Calculated IndustriesメーカーScale Master Pro XEの使用説明書/サービス説明書
ページ先へ移動 of 43
.
S CALE M ASTER ® P RO XE Introduction The Scale Master Pro XE Multi-Scale Digital Plan Measure has been specifically designed to simplify takeoffs from architectural and engineering drawings.
T ABLE OF C ONTENTS Getting Started Key Definitions ................................................1 Operation Keys .............................................1 Setup Keys .....................................................3 Measuring Keys ......
Appendix Error/Auto-Range Function ....................... 30 Interference .................................................... 30 Battery/Automatic Shut-Off ...................... 31 Battery Replacement ..................................... 31 Default Settings .
1 – Scale Master ® Pro XE G ETTING S TARTED Key Definitions Operation Keys [ON/CLEAR] – On/Clear T urns power on. Press once to clear the display . This will not clear the last rolled measurement as it is a per manent value and can be recalled to the main display at any time by pressing [RCL] [RCL] .
[RESET] – Hardware Reset If your Scale Master Pro XE should ever “lock up ,” use a paperclip or similar size object to press the RESET hole. Clears all values , including memor y .
[LOCK] – Lock Switch The Lock Switc h is located on the side of the unit. When the lock is activ ated, a lock symbol will be displayed in the LCD . While active y ou cannot alter Scales , Modes, Units , Preferences or the IMP/ MET (Imperial/Metric) switch.
[SUB] + [SCALE] – Scrolls Back Scales Holding [SUB] and repeated presses of [SCALE] will scroll backward through the av ailable scales . [UNITS] – Unit Selection Repeated presses of [UNITS] will scroll through the av ailable units of measurement. See “Imperial Units” and “Metric Units” sections .
[ T ] ([RCL]) – Down Arrow Decreases the number when setting v alues for custom scales, auto-count, constant, and height. Will scroll down through the preferences . [ S ] ([M+]) – Up Arrow Increases the number when setting v alues for custom scales, auto-count, constant, and height.
1) Area 2) Perimeter 3) V olume (if Height is entered) 4) W all Area (if Height is entered) 5) Stored Height (if Height is entered) 6) Stored Length 7) Stored Width [RCL] [W/LxW] – Width Recall Displays the stored width v alue. On a clear display , [W/LxW] can be pressed without [RCL] .
Function Keys [M+] – Memory Plus Adds the displa yed value to the accumulativ e value. [RCL] [M+] – Memory Recall Displays the value stored in accum ulativ e memory . [ON/CLEAR] + [M+] – Memory Clear Clears the accumulativ e memory value. [SET] [M+] (M-) – Memory Minus Subtracts the displa yed value from the accumulativ e memor y .
[RCL] [SET] [COUNT] – Auto-Count Recall Displays the stored A uto-Count value . [ X PC] – PC Send When connected to a PC, sends the v alue from the main display of the Scale Master Pro XE to the PC. All values are sent in decimal for mat. [+K] – Constant Add Adds the constant v alue to the displayed measurement value .
Rotate to Adjust Wheel Adjusting the Wheel The Celcon ® polymer wheel can be adjusted for each user’ s preference . T o adjust the wheel, take a small, flat-head jeweler’ s screwdriv er and slightly rotate the screw located near the wheel tip . R otating the screw about 1/4 to 1/3 turn should be sufficient.
Preferences Preferences allow customization of how the Scale Master Pro XE functions during cer tain operations . The following preferences are av ailable: Button Beep (butn) – T og gles on or off the beep sound that occurs at the press of a button or during auto-count.
(cont’ d) PC T er minate (End PC) – Deter mines where the “cursor” mov es after a value is sent to the PC. The settings represent the key being pressed on the PC keyboard: Enter – PC Enter T.
Setting Preferences: 1) Press [SET] [MODE] to access the preferences . 2) Press the [M+] ( S ) key to move up or the [RCL] ( T ) key to move down through the list of preferences .
Built-In Scales Imperial (Standard) Units Architect Engineer-I Engineer-II Map ARCH ENGI ENGII MAP 1 foot= 1 inch= 1 inch= 1 inch= 1/4” 10.0’ 300.0’ 1.0 Mi 3/8” 20.0’ 333.3’ 1.5 Mi 1/2” 30.0’ 400.0’ 2.0 Mi 3/4” 40.0’ 416.6’ 3.0 Mi 1/1 (1”) 50.
Metric Units Architect Engineer-I Engineer-II Map ARCH ENGI ENGII MAP 1:50 1:100.0 1:1,000 1:100k 1:75 1:125.0 1:1,250 1:125k 1:1 1:150.0 1:1,500 1:200k 1:2 1:200.0 1:1,625 1:250k 1:3 1:250.0 1:2,000 1:500k 1:4 1:300.0 1:2,500 1:1,000k 1:5 1:400.0 1:5,000 1:2,000k 1:10 1:500.
Changing Modes Repeated presses of the [MODE] key will scroll through the list of av ailable modes . Holding [SUB] when pressing [MODE] will scroll backward through the list of available modes . Changing Scales Repeated presses of the [SCALE] key will scroll through the list of av ailable scales .
Operation User’s Guide – 16.
Rolling a Measurement T o take a measurement with the Scale Master Pro XE : 1) T urn the unit on. If the display does not show zero (0), press the [ON/CLEAR] key to clear the display . 2) Select your type of scale by pressing the [MODE] key . Then press the [SCALE] key to select your scale .
Using the Memory Function The Memor y function allows you to add rolled or counted values . However , you cannot add dimensioned (rolled) and non- dimensioned (counted) values together . T o add rolled values: 1) Roll the first v alue.* Press [M+] . The Memory indicator “ M ” appears and the value is added to Memory .
Additional Memory Functions [SET] [M+] Subtracts the value in the main displa y from the value stored in Memory . [RCL] [M+] Displays the total accumulated v alue in Memory . Repeated presses of [M+] will tog gle between total accumulated v alue, number of entries in Memor y , and av erage value of all entries in Memory .
Programming Mode The Scale Master Pr o XE allows you to pre-set frequently used values , including: ● Custom Scales (5 Imp/5 Met) ● Auto-Count distance ● +K (Constant) value ● Height value T o begin setting values , press the [SET] key and then the desired key to be programmed.
Setting Custom Scales Y ou can store ten Custom Scales: five in Imperial Mode and fiv e in Metric Mode. Y ou can set a custom scale two wa ys: by “rolling in” a known distance or by entering the exact distance. Rolling a Custom Scale 1) Press [MODE] until # O P E N (# being a number 1-5) appears in the scale box display.
6) Press [M+] ( S ) to increase or [RCL] ( T ) to decrease the selected digit. Press the [W/LxW] ( X ) key to mov e to the next digit to the right or the [L] ( W ) key to mov e back to the left. 7) Once the desired v alue has been entered, press [SET] to store value and exit the programming mode.
(cont’ d) 4) T o chang e the units of measurement, press [UNITS] until your desired units appear . Press the [W/LxW] ( X ) or the [L] ( W ) key to begin setting the distance . The selected digit will star t flashing. 5) In Imperial mode , the scale will be one inch equals the distance you entered.
Setting an Auto-Count The Scale Master Pr o XE has an Auto-Count function that allows you to count ho w many times you’v e rolled a certain distance. Y ou will hear a beep each time you roll that distance. T o set an Auto-Count: 1) Press [SET] [COUNT] to access the Auto-Count function.
(cont’ d) 4) Once the desired v alue has been entered, press [SET] to save c hanges and put the unit into Auto-Count mode . 5) R oll a distance. The unit will beep each time you roll the programmed distance. The count number in the display will increase.
2) T o chang e the units of measurement, press [UNITS] until your desired units appear . Press the [W/LxW] ( X ) or the [L] ( W ) key to begin setting the distance . The selected digit will star t flashing. 3) Press [M+] ( S ) to increase or [RCL] ( T ) to decrease the selected digit.
Setting a Height The height function is used to enter a height value for finding v olume. T o set a Height: 1) Press [SET] [L] to access the height function. The appropriate annunciator will begin flashing “ FT IN ” for Imperial mode or “ M ” for Metric mode.
Finding Area 1) Roll the first side and press the [L] key to store as Length. 2) Roll the second side and press [W/LxW] to store as Width. The main display will show the calculated Area. Finding Volume T o access V olume after you hav e your values set for Length, Width, and Height, press [SET] [W/LxW] .
Additional Area/Volume Functions [RCL] [L] Displays the v alue stored in the Length register . [RCL] [W/LxW] Displays the v alue stored in the Width register . [ON/CLEAR] + [L] Clears the value stored as Length. [ON/CLEAR] + [W/LxW] Clears the value stored as Width.
A PPENDIX Error/Auto-Range Function Error M essage – If you make an incorrect entry (such as tr ying to add dimensioned and non-dimensioned values together), the Scale Master Pro XE will display the word “ ERROR .
Battery/Automatic Shut-Off The Scale Master Pro XE is powered b y two 3-V olt CR-2032 Lithium batteries (6 volts total). T o conser ve battery power , the unit will shut itself off if it is not used for 4-6 minutes . Press the [ON/CLEAR] to restore power .
Default Settings The following are the factory defaults of the Scale Master Pro XE : Default Default Settings Imperial Metric Mode ARCH ARCH Scale 1/4" 1:50 Custom Scales 1”:1” 1:1 Linear FT IN MM Area SQ FT SQ M V olume CU YD CU M Length 0-0 0.
Specifications Power Source: T wo 3-V olt CR-2032 lithium batteries . Approximately 400 hours normal use. Display Method: LCD with commas, annunciators and zero suppression. Display Capacity (Main Display): 9,999,999 (7 digits) Resolution/Accuracy: .025 Inch/99.
Repair and Return Repair and Return Information Return Guidelines: 1. Please read the W arranty in this User's Guide to deter mine if your Calculated Industries product remains under warranty before calling or retur ning any device for evaluation or repairs .
Warranty Warranty Repair Service — USA Calculated Industries (“CI”) w arrants this pr odu ct against defe ct s i n ma te r ia l s an d wor k ma ns h ip for a p er io d of on e (1) yea r f rom t h e da te of or i g i na l c ons u mer p u rc ha se i n t he U.
Repair Service — Outside the USA T o o b t a i n w a r r a n t y o r n o n - w a r r a n t y r e p a i r s e r v i c e f o r go od s pu rc ha se d out sid e t he U. S ., co nta ct t h e de al er t hr ou gh w h ich y ou i n it i al l y pu rc ha se d t he pr odu ct .
FCC Class B Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to P art 15 of the FCC Rules . These limits are designed to provide reasonable protection against har mful interference in a residential installation.
User’s Guide – 38 Mail Calculated Industries, Inc. 4840 Hytech Drive Carson City, NV 89706 U.S.A. Phone (775) 885–4900 Fax (775) 885–4949 E-mail techsup@calculated.
Software copyrighted and licensed to Calculated Industries by Scale Master Technologies, LLC, 2009. User’s Guide copyrighted by Calculated Industries, 2009. Scale Master ® and Calculated Industries ® are registered trademarks of Calculated Industries, Inc.
デバイスCalculated Industries Scale Master Pro XEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Calculated Industries Scale Master Pro XEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCalculated Industries Scale Master Pro XEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Calculated Industries Scale Master Pro XEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Calculated Industries Scale Master Pro XEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Calculated Industries Scale Master Pro XEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCalculated Industries Scale Master Pro XEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Calculated Industries Scale Master Pro XEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCalculated Industries Scale Master Pro XEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。