ADTRANメーカーSLC-5 U-BR1TE IIIの使用説明書/サービス説明書
ページ先へ移動 of 14
Section 61102040L4-5, Issue 2 61102040L4-5B 1 1. GENERAL This practice provides installation and maintenance information for the ADTRAN SLC-5 U-BR1TE III w/ PWR and DDS Loopbacks (U-BR1TE III).
Section 61102040L4-5, Issue 2 61102040L4-5B 2 • Loopback release in response to TIPs generated from the network direction per TR62310. • Remap all subsequent DS0 DP loopback codes into respective eoc loopbacks to loopback respective downstream U-Repeaters, TRISDN elements, and U-BR1TES when optioned for 1B+D, or 2B+D.
Section 61102040L4-5, Issue 2 61102040L4-5B 3 C A U T I O N C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. The U-BR1TE III will function with any ISDN 2B1Q U-interface that is ANSI T1.601 compliant.
Section 61102040L4-5, Issue 2 61102040L4-5B 4 NOTE When the U-BR1TE III is optioned for B1 or B2, the SLC-2000 slot must be provisioned for D only. If the U-BR1TE III is optioned for 2B, then the SLC-2000 slot must be provisioned for B1+D. Physical Requirements The U-BR1TE III occupies one physical slot in the SLC-5 or SLC-2000 channel bank.
Section 61102040L4-5, Issue 2 61102040L4-5B 5 e p y T e c i v r e S e c i v r e S n o i t p On o i t p O n o i t p O n o i t p On o i t p O 1 - 1 W S ) 1 B () 1 B ( ) 1 B ( ) 1 B () 1 B ( 2 - 1 W S ) .
Section 61102040L4-5, Issue 2 61102040L4-5B 6 Figure 5 displays the position switch settings at ISDN network locations. Figure 5. Position Switch Settings at Network Locations for ISDN Applications 2-.
Section 61102040L4-5, Issue 2 61102040L4-5B 7 Figure 6. SLC-5 U-BR1TE III IDSL/DDS Circuit Diagram 4W DS0 DP or OCU DP T1 T1 D4 AB C D E D4 RT 4W DS0 DP or DCS 2-Wire Local Loop 2-Wire Local Loop 4W D.
Section 61102040L4-5, Issue 2 61102040L4-5B 8 Front Panel Features The RJ-45 jack allows front panel test access for local or downstream loopbacks. The address select knob (SW3) determines which element is being looped back. Table 3 lists the loopback options.
Section 61102040L4-5, Issue 2 61102040L4-5B 9 To initiate a point-to-point test, perform the following: 1. Connect the DS0 digital tester to the RJ-45 jack. 2. Configure the test set for Near Logic and 64kbps. 3. Select the desired test direction and bearer channel using the address select knob.
Section 61102040L4-5, Issue 2 61102040L4-5B 10 When the U-BR1TE III operation is normal, the ADR7 position of SW1 does not have a function. NOTE This test option is only available on power up of the U-BR1TE III.
Section 61102040L4-5, Issue 2 61102040L4-5B 11 DS0 DP Loopback eoc Remapping Upon receipt of subsequent DS0 DP loopback codes when the D channel is disabled, the U-BR1TE III remaps the subsequent DS0 DP loopback sequences into the respective ISDN eoc loopback messages.
Section 61102040L4-5, Issue 2 61102040L4-5B 12 Remote End Initiated LBK Tests The U-BR1TE supports loopbacks generated from the IDSL OCU-R which allow testing to be performed without coordination with the CO or test center.
Section 61102040L4-5, Issue 2 61102040L4-5B 13 Figure 11. IDSL/DDS Trouble Codes MOS 9Ah Channel Bank Open 2-wire Loop DSU IDSL OCU-R U-BR1TE Customer Premises ASC 9Eh Channel Bank ASC 9Eh Open 4-Wire.
Section 61102040L4-5, Issue 2 61102040L4-5B 14.
デバイスADTRAN SLC-5 U-BR1TE IIIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
ADTRAN SLC-5 U-BR1TE IIIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはADTRAN SLC-5 U-BR1TE IIIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。ADTRAN SLC-5 U-BR1TE IIIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。ADTRAN SLC-5 U-BR1TE IIIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
ADTRAN SLC-5 U-BR1TE IIIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はADTRAN SLC-5 U-BR1TE IIIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、ADTRAN SLC-5 U-BR1TE IIIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちADTRAN SLC-5 U-BR1TE IIIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。