1 OPERA TING INSTRUCTIONS EN PROTECT PV 2000 AND 2800 ON-GRID SOLAR INVERTER DOC N° 07/08/1002-2 Rev 04.
2 Before you start 2 Safety instructions 4 Limited Warranty 5 1. Overview 9 2. Features 10 3. Installation instructions 11 Opening the package 11 Before installation 11 Mounting Protect PV to the wall 12 Connecting to the grid (AC utility) 14 Connect to PV Panel (DC input) 16 Checking 16 4.
3 BEFORE YOU ST ART Congratulations on purchasing your Pr otect PV 4600 Grid PV -Inverter from AEG Power Solutions GmbH r eferred to in this manual as “PV -Inverter”, or simply the “device”). This PV -Inverter is a highly reliable pr oduct due to its innovative design and perfect quality control.
4 RISK OF ELECTRIC SHOCK 1. Do not remove the casing. Protect PV ® contains no user serviceable parts. Refer servicing to qualified service personnel. Both AC and DC voltage sources are terminated inside the PV-Inverter. Please disconnect these circuits before servicing.
5 LIMITED W ARRANTY The limited warranty provided by AEG Power Solution (“AEG PS”) in this Statement of W arranty applies only to Equipment purchased for residential, commer cial or industrial use in the ordinary course of the business.
6 accidents brought about by the Pur chaser‘s actions, such as negligence, connection error , failure to follow instructions for maintenance, abnor - mal use due in particular to electrical or mechanical overload. Any parts furnished under this warranty may be new or factory-remanu- factured.
7 EXCLUSIONS AEG PS shall not be liable under the W arranty if its testing and exa- mination discloses that the alleged defect in the Equipment does not exist or was caused by your or any third person.
8 WARRANTY EXTENSION The original factory warranty can be extended by purchasing additional Extended W arranty Program which extends factory warranty by five (5) years from the date the original factory warranty is ending and guaranty repair and/or r eplacement of defective parts.
9 1. OVERVIEW Protect PV 2000 & 2800 DISPLA Y INFORMA TION SWITCH LCD DISPLA Y : SHOWING THE INVERTER ST A TUS SOLAR P ANEL INPUT RS232 COVER RS485 SLOT UTILITY (AC) CONNECTION OPERA TION LED, GRE.
10 2. FEA TURES • V ery high conversion efciency (>96%) • MPPT (Maximum Power Point T racking) • Higher power capacity than similar products of the same size. • Embedded LCD display showing complete status information • Natural convection cooling.
11 3. INST ALLA TION INSTRUCTIONS OPENING THE P ACKAGE After opening the package, please check the contents of the box. It should contain the following: 1. One Protect PV inverter 2. Instruction manual 3. One mounting frame 4. 4 mounting screws 5. 2 safety-lock screws 6.
12 MOUNTING PROTECT PV TO THE WALL 1. Select a wall or solid vertical surface that can support the PV -Inverter . 2. Protect PV requir es adequate cooling space. Allow at least 20cm space above and below the inverter . 3. Using the mounting frame as a template, drill 4 holes as illustrated in the following figures.
13 6. Check the installation conditions a) Do not install the PV - Inverter on a slanted surface b) Check the upper straps of PV -Inverter and ensure it fits on to the bracket c) Insert safety-lock screws to the bottom leg to secure the inverter . Check the secure mounting of the PV -Inverter by trying to raise it from the bottom.
14 CONNECTING TO THE GRID (AC UTILITY) 1. Measure grid (utility) voltage and frequency . It should be 230VAC or 220V AC), 50/60Hz, and single phase. 2. Switch off by breaker or fuse between PV -Inverter and utility . 3. For Protect PV 2000 and 800, connect AC wires as follows: • Disassemble female socket.
15 • Connect Phase to pin 1, Neutral to Pin 2 and PE to Pin • Assemble the socket again and attach. • T wist the coupling ring to the PV -Inverters receptacle. Make sure it is correctly matched. T o prevent risk of electric shock, ensur e that PE is properly grounded befor e operating the PV -Inverter .
16 CONNECT TO PV P ANEL (DC INPUT) 1. Make sure the maximum open circuit voltage (V oc) of each PV string is less than 450VDC UNDER ANY CONDITION. W e recommend V oc less than 360VDC with ambient temperature of 25C. 2. Use MC 3 (Multi-contact) connectors for PV array terminals.
17 4. SYSTEM DIAGRAM The typical connection diagram for the entire PV system is shown in the following fi gure. 1. PV -Panel: Provide DC power to Pr otect PV inverter 2. Protect PV PV -Inverter Converts DC (Direct Curr ent) power from PV panel(s) to AC (Alternating Current) power .
18 5. OPERA TING YOUR PV -INVERTER MODES OF OPERA TION There ar e 3 differ ent modes of operation. 1. Normal mode: In this mode, Protect PV works normally . Whenever the supplied power from PV panel is sufcient (voltage>150VDC), Protect PV converts power to the grid as generated by the PV panel.
19 • Nor mal operation: When PV string DC voltage is greater than 150V , Protect PV operates in the normal state. In this state, it feeds power to the grid. Protect PV automatically stops when the PV power is not enough. a. Press the “Function” key repeatedly until “Contrast” shows in the display .
20 MAXIMUM POWER POINT TRACKING (MPPT) A good PV inverter must be able to convert the maximum power from any PV panel. Due to its advanced design, Protect PV PV -Inverter can track the maximum power from your PV panel in any condition.
21 6. INVERTER ST A TUS Protect PV is designed to be user -friendly; therefor e, the status of the Inverter can be easily understood by reading the information shown on the front panel display .
22 Feeding current Iac=xx.xA Feeding current amount in xx.x A PV array voltage Vdc=xxx.xV Input voltage from PV array , xxx.x VDC SYSTEM F AUL T Isolation failure ERR ISOLA TION Earth fault of the PV .
23 INVERTER INFORMA TION Model display MODEL PV 4600 Inverter model, xkW inverter LCD Contrast CONTRAST The top menu of LCD contrast setting LCD contrast setting SET CONTRAST Setting the contrast of L.
24 7. COMMUNICA TIONS Protect PV is equipped with a powerful communications interface and options. Use Protect PV Monitor to monitor the status of your PV Inverter . Also, qualifi ed personnel can upgrade the fi rmware using the RS232 port. 1. RS232: T o use the RS232 port, remove the RS232 cover on the bottom side of Protect PV .
25 3. Firmware upgrade: T o keep the firmware up to-date, use the RS232 port and supplied program to upgrade firmwar e. T o do this, please contact your local AEG PS service T o prevent risk of damage it is r ecommended that only authorized personnel perform firmware upgrades.
26 8. TROUBLE SHOOTING In most situations, the Protect PV inverter r equires very little service. However , if Protect PV is not able to work perfectly , please refer to the following instructions before calling your local AEG PS dealer .
27 • If there is no display on the panel, please check PV -input connections. If the voltage is higher than 150V , call your local service. • During periods of little or no sunlight, the PV -Inverter may continuously start up and shut down. This is due to insufficient power generated to operate the control cir cuits.
28 9. SPECIFICA TIONS Product specifications ar e subject to change without notice MODELL Protect PV 2000 Protect PV 2800 DC INPUT Nominal DC voltage 360 VDC 360 VDC max. PV open voltage 500 VDC 500 VDC MPPT range 150–450 VDC 150–450 VDC W orking range 100–500 VDC 100–500 VDC Number of MPP T racker 1 1 max.
29 TYPICAL EFFICIENCY CHARTS VS. LOAD Hinweis: Aufgrund von T oleranzen der T estgeräte, Umgebungsbedingungen und Modellspezifikationen können tatsächliche Ergebnisse abweichen.
30 10. REGULA TION & CERTIFICA TES INCIDENT FORM COMPLIANCE & ST ANDARDS EMC: DIN EN 50081, part 1 (EMV -interference emission) (EN 55014, EN 60555 part 2, EN 55011 group 1, class B) DIN EN 50082, part 1 (EMV -interference immunity) GRID INTERF ACE: DIN EN 61000-3-2 GRID MONITORING: EN DIN VDE 0126 (1999.
31.
32 AEG Power Solutions GmbH Emil-Siepmann-Str . 32 59581 Warstein-Belecke - Germany T el.: +49 (0) 2902 763-520/-290 - Fax: +49 (0) 2902 763-1201 www .
デバイスAEG 2000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
AEG 2000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAEG 2000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。AEG 2000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。AEG 2000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
AEG 2000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAEG 2000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、AEG 2000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAEG 2000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。