Adit 3200 Q UICK S TART G UIDE Part Number: 002- 0246-0010 Product Release: 1.6 September 2007.
Copyright 2007 Carrier Access Corporation. All rig hts reserved. The information presented in this manual is subject t o change without notice an d does not represent a commitm ent on the part of Carrier Access Corporation. The hardware and softwa re described herein are furnished under a license or non- disclosure agreement.
Q UICK S TART G UIDE Quick Start In this Guide Unpacking and Inspection Installation Environment User Safety Installation - Compliant Installation - Wall Mounting - Rack Mounting (O pt.
4 Adit 3200 - Relea se 1.6 Quick Start Unpacking and Inspection Unpacking and Inspection W ARNING! O BSERV E PRECAUTIONS FO R HANDLING ELECT ROSTATIC DEVICES . 1. Inspect containers for damag e during shipment . Report any damage to the freight carrier for possible insurance claims.
Adit 3200 - Release 1.6 5 Quick Start User Safety User Safety CAUTION! W HEN USING YOUR TEL EPHONE EQUIPMENT , BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE , ELECTRIC .
6 Adit 3200 - Relea se 1.6 Quick Start Installatio n Compliant Installation NOTE: It is important the DS1/E1 Network Interface Cables are secured separately from the power and Signal Cables. 1. Inspect the unit. 2. Mount the unit, see Wall Mounting on page 7, or Rack Mounting (Optional Feature) on page 8 for detailed instructions.
Adit 3200 - Release 1.6 7 Quick Start Installation Wall Mounting Before beginning the mounting process , verify that the installation area is a stable environment, clean and free from extremes of temperature, shock, vibration and EMI. See Installation Environment on page 4.
8 Adit 3200 - Relea se 1.6 Quick Start Installatio n Rack Mounting (Optional Feature) NOTE: Rack mounting kits are availab le for both 19 and 23 inch racks. 1 Rack Unit (RU) of spacing is required above the Adit 3000 in the Rack Mount Unit. To rack mount the Adit 3000, fo llow the instructions below: 1.
Adit 3200 - Release 1.6 9 Quick Start Installation 4. Place the Adit on the Tray Slide and att ach with 4 screws removed in step 2. 5. Slide the assembled piece (Adit 3000 and Tray Slide) onto th e installed Rack Mounting Tray. 6. Secure the Tray Slide to the Rack Mounting Tray with the att ached screws on the Tray Slide.
10 Adit 3200 - Relea se 1.6 Quick Start Installatio n Adit 3104, 3200, 3300 an d 3400 Battery Backup The Adit 3104, 32 00, 3300 and 3400 Battery Backup (P/N 730-0132 ), is a wall-mount battery backup unit to provide up to 8 hours battery backup .
Adit 3200 - Release 1.6 11 Quick Start Chassis Overview Chassis Overview (1) 10/100Ba se-T Ethernet (WAN) (4) 10/100Base- T Ethernet (LAN) Alarm Status Reset RS-232 Management Port Power/Battery/Statu.
12 Adit 3200 - Relea se 1.6 Quick Start Interface Connectors Interface Connectors The following are the Adit 3200 interface connectors: Front of Adit z (1) DS1 WAN port (RJ-48C).
Adit 3200 - Release 1.6 13 Quick Start Interface Connectors Power The Adit 3000 is powered by a limited -48 VDC Po wer source. The following options are available: z AC/DC Converter z Battery Backup module AC/DC Converter An AC/DC Converter generates 48VDC from any worldwide AC power source.
14 Adit 3200 - Relea se 1.6 Quick Start Interface Connectors RS-232 Craft Port (Female DB-9) The RS-232 craft port connector (female) is for co nnection to an external PC or Hayes-compatible modem for local or remote configuration, mana gement, and performance monitoring using the Adit 3000 Command Lin e Interface (CLI).
Adit 3200 - Release 1.6 15 Quick Start Interface Connectors DS1/E1 Connection Ports Each DS1/E1 connec tion port is equipped with a standard RJ-4 8C (female) on the Adit 3000 unit.
16 Adit 3200 - Relea se 1.6 Quick Start Reset Button 10/100Base-TX Ethernet The 10/100Base-TX Ethernet (female) po rts provide connectivity for Router WAN and/or LAN ports and for manage ment connection via Telnet and/or SNMP to a Network Management System.
Adit 3200 - Release 1.6 17 Quick Start Alarm/Status LEDs Alarm/Status LEDs LED State Description Critical Off No critical alarms present Red Critical alarms present. Critical alarms include: user-conf igured manor environment al inputs. Major Off No major alarms present Red Major alarm present.
18 Adit 3200 - Relea se 1.6 Quick Start Web-Based Management Web-Based Management The web-based mana gement interface allows you to control various system parameters. The interface is accessed through a web browser. To access the management console: NOTE: The following assumes that you have connected the PC to the LAN port of the Adit 3200.
Adit 3200 - Release 1.6 19 Quick Start Setting up a CLI Connecti on Setting up a CLI Connection A CLI connection will require t he LAN or WAN IP ad dress of the unit.
20 Adit 3200 - Relea se 1.6 Quick Start Log in Log in After successful connection, via telnet or HyperT erm, the user must login. Default Logins are: Login: admin Password: admin123 After successful login the prompt will be displayed as follows: Adit 3200> NOTE: It is recommended that you cha nge your password from the default.
Adit 3200 - Release 1.6 21 Quick Start Key Enabled Software Features Key Enabled Software Features The Adit 3200 has additional features that are not pr ovided on the base system. These features can be purchased with the product or added later as needed .
22 Adit 3200 - Relea se 1.6 Quick Start Basic Configuration Basic Configuration The following configuration is divided into logical sections, where each sect ion configures an additional function. The first must be config ured before the second and so forth, however, yo u may stop at any section and not add the following feat ure.
Adit 3200 - Release 1.6 23 Quick Start Basic Configuration Restore Factory Defaults If the unit is not out-of-the-box, you may want to verify t hat the unit is set to defaults. Note: This will reset the IP address back to th e default setting of 192.168.
24 Adit 3200 - Relea se 1.6 Quick Start Basic Configuration Modify Default Admin User For security purposes it is recommended that the Ad ministrator User be changed from the default settings. Modify the Administrator User in the web-browser: z Select Advanced from the Navigation bar z Select Users icon z Select Administrato r, to open the profile.
Adit 3200 - Release 1.6 25 Quick Start Basic Configuration z Modify the User info rmation, and select OK to save. It is important t o note that you need to have a minimum of on e user with Administrative Privileges . For users with other access levels, add a New Use r .
26 Adit 3200 - Relea se 1.6 Quick Start Basic Configuration Configure Ethernet WAN Interface In the web-browser: 1. Select Network Connections from the Navigation bar. 2. It is recommended that you disable/delete the Serial1 port. 3. Select (click) Ethernet 2 (WAN Ethernet) connection to configure.
Adit 3200 - Release 1.6 27 Quick Start Basic Configuration 6. Set Internet Protocol to Obtain an IP Address Automatically , from the pulldown menu. This will enable the Adit 3200 as a DHCP Client. Leave the other fields to their default settings. 7. Select Apply to apply the new settings.
28 Adit 3200 - Relea se 1.6 Quick Start Basic Configuration Configure Serial 1 as WAN In the web-browser: 1. Select Network Connections from the Navigation bar. 2. Select Serial 1 . 3. Select Settings button. 4. Set Network to WAN . 5. Select Apply to apply the new settings.
デバイスCarrier Access 3200の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Carrier Access 3200をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCarrier Access 3200の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Carrier Access 3200の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Carrier Access 3200で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Carrier Access 3200を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCarrier Access 3200の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Carrier Access 3200に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCarrier Access 3200デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。