52C SERIES 1•800• 894•6449 (in USA and Can ada) F or Ser vice/T echnical As sistance 1•800•830•8600 (Me xico) OWNER’S MANUAL P ACKAGED TERMINAL AIR CONDIT IONERS AND HEA T PUMPS 7,000-15,0 00 Btuh CONTENTS Page GENERAL . . . . . . . . . .
2 GENERAL Thank you for choosing Carrier! You can feel confident in your se lection becaus e the same prid e in craftsman- ship a nd engi neering knowled ge that g oes int o Carrie r equipme nt at the.
3 To in stall the front pan el follow the pr ocedure ou tlined below: 1. Firmly g rasp bottom of front panel on both si des. 2. Hold front pan el at a 45 deg ree angle to unit. Be sure front panel is ce ntered with front of uni t. 3. Conn ect top of front p anel to par tition rai l on top of unit.
4 ELECTRICAL DA T A Be sure that your o utlet mat ches the appropri ate blade con figuration o f the supp lied plug and that it is within reach of the service cord. A hardwire kit is available as an accessory to change cord-connected units to hardwired units.
5 INST ALLA TION CHASSIS INST ALLA TION Units ar e shipped wi thout a sleeve. I n applicati ons where uni t is a replace ment, it is re commended that a Carrier sleeve b e us ed. The 5 2C and 52P units can retrofit General Ele ctric, Aman a and Trane sleeve s/ grilles (be sure ou tdoor gr ille is instal led on the sleev e).
6 ■ INST ALL CHASSIS IN SLEEVE (Se e Figures 6 to 9) 1. Inspect foam gaskets ( t op , bot tom, both sid es) on chassi s. Replace foam ga skets i f t orn or missing. 2. Remove shipping tape from vent door. See Figure 7. 3. Lif t chassi s level wi th wall sl eeve.
7 W ALL THERMOST A T INST ALLA TION The follow ing instruction s apply to RC a n d RP units onl y. NOTE: Carrier thermostats are recommended. See Accessories section. ■ INST ALL THERMOST A T — All remote control units. 1. Chec k to be su re power to unit is d isconnecte d.
8 OPERA TION COMFOR T CONTROLS ■ ADJUST AIRFLOW DIRECTION — The disc harge air grille is mounted on the fron t panel so th at the a ir discharges forward. If upward discharge is required , remove the grille by removing screws o n back of front panel.
9 OPERA TING CONTROLS The foll owing controls a r e located on the front o f the control b ox door, under fron t panel. To obtain access t o operating cont rols, remove the unit f ront panel as shown on page 2. See Figure 14. ■ F AN CYCLE SWITCH — (Not availabl e on RC or RP units.
10 CARE AND MAINTENANCE In or der to maintai n prop er per forma nce of your pa ck- aged terminal air conditioner or heat pump, it is very importan t that the fan and ou tdoor coil, the blower wheel, blower scro ll, electric hea ter, and al l drain pa s- sages ar e thoroughl y cleaned at least o nce per year.
11 EXTERNAL P AR TS ■ EXTERNAL P AR TS in clude the polyme r sleeve and grilles. The sleev e manufacturer recommends cleaning the surface, in cluding the grille s, with household detergent and water. INTERNAL P AR TS ■ INT ERNAL P AR TS should be c leaned at least on ce duri ng the ye ar.
12 PREVENT A TIVE MAINTENANCE Preventativ e maintenance is essenti a l to prope r unit operatio n, efficiency and longevity. To assure equip- ment opera t e s pro perly it must be properly main - taine d. Equipme nt operati o n shoul d be checked and verified several times during each ye ar.
13 TROUBLESHOOTING NO TES: 1. If circuit breaker is t ripped or fuse is b lown more than once, contact a qualif i ed elect rician. 2. If unit is installed where condensation dr ainage could dr ip in an undes i rable location, an accessor y drain kit should be installed and connected to dr ain syst em.
14 ACCESSORIE S *Extend ed metal wall sleev e also available in 26 in. and 28 in. dept h. † Custom colors are also a v ailable. A CCESSOR Y FORM NUMBER P ART NUMBER DESCRIPTION Wall S leeves 52S-48 .
15 Carrier P ackaged T er m inal Air Condit ioner W arra nty FULL ONE-YEAR W ARRANTY — Durin g the first year after pu rchase, CARRIER will, through its auth oriz ed independent ser vicing dealers o.
Copyright 20 02 Carri er Cor poration Manufa cturer re serve s the ri ght to dis continue , or chan ge at a n y t ime, s pecifica tions or design s without notice and withou t inc urring obligations.
デバイスCarrier Access 52Pの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Carrier Access 52Pをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCarrier Access 52Pの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Carrier Access 52Pの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Carrier Access 52Pで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Carrier Access 52Pを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCarrier Access 52Pの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Carrier Access 52Pに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCarrier Access 52Pデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。