Adit 3500 Q UICK S TART G UIDE Part Number: 002- 0250-0010 Product Release: 1.6 September 2007.
Copyright 2007 Carrier Access Corporation. All rig hts reserved. The information presented in this manual is subject t o change without notice an d does not represent a commitm ent on the part of Carrier Access Corporation. The hardware and softwa re described herein are furnished under a license or non- disclosure agreement.
Q UICK S TART G UIDE Quick Start Guide In this Guide Unpacking and Inspection Installation Environment User Safety Installation - Compliant Installation - Ferrite Beads - Wall Mounting.
4 Adit 3500 - Relea se 1.6 Quick Start Guide Unpacking and Inspection Unpacking and Inspection W ARNING! O BSERV E PRECAUTIONS FO R HANDLING ELECT ROSTATIC DEVICES . 1. Inspect containers for damag e during shipment . Report any damage to the freight carrier for possible insurance claims.
Adit 3500 - Release 1.6 5 Quick Start Guide Installation Environm ent Installation Environment The environment in whic h you are installing the Adit 3000 mu st meet the following conditions: z Operati.
6 Adit 3500 - Relea se 1.6 Quick Start Guide Installatio n Installation The following are instructions for a compliant i nstallation of the Ad it 3500.
Adit 3500 - Release 1.6 7 Quick Start Guide Installation Compliant Installation NOTE: It is important the DS1/E1 Network Interface Cables are secured separately from the power and Signal Cables. 1. Inspect the unit. 2. Mount the unit. z Wall mounting installation, see Wall Mounting on pag e 9 .
8 Adit 3500 - Relea se 1.6 Quick Start Guide Installatio n Ferrite Beads The following ferrite bead is requ ired on the Adit 3500 co nfigurations that do not have the FXS 4 channel option. The ferrite bead will enable the Adit to be compli ant with EMI standards FCC Part 15 and ICES-003 Class A.
Adit 3500 - Release 1.6 9 Quick Start Guide Installation Wall Mounting Before beginning the mounting process , verify that the installation area is a stable environment, clean and free from extremes of temperature, shock, vibration and EMI. See Installation Environment on page 5.
10 Adit 3500 - Relea se 1.6 Quick Start Guide Installatio n Rack Mounting This is an Optional Feature. NOTE: Rack mounting kits are available for both 19 and 23 inch racks. 1 Rack Unit (RU) of spacing is required above the Adit 3000 in the Rack Mo unt Unit.
Adit 3500 - Release 1.6 11 Quick Start Guide Installation 4. Place the Adit 3000 on the Tray Slide and a ttach with the 4 screws removed in step 2. 5. Slide the assembled piece (Adit 3000 and Tray Slide) onto th e installed Rack Mounting Tray. 6. Secure the Tray Slide to the Rack Mounting Tray with the att ached screws on the Tray Slide.
12 Adit 3500 - Relea se 1.6 Quick Start Guide Installatio n Battery Backup This is an Optional Feature. The Adit 3500 Battery Backup is designed specifically for the Adit 3500. The battery back up un it is a single 12V sealed lead-acid battery in a metal enclosure designed for wall mounting.
Adit 3500 - Release 1.6 13 Quick Start Guide Installation #1 Adit 3500 mounted on top of the Battery Backup This method will use a minimal amount of wall space. Note: This installation will require a minimum wall space of space of: 9" (H) x 14" (W) x 5" (D).
14 Adit 3500 - Relea se 1.6 Quick Start Guide Installatio n 4. Attach Adit 3500 to the assembled BBU and brackets. z Each bracket attaches to the side of the Adit 3500. Note the orientation of the Adit in the graphic. 5. Attach powe r cords. z Connect cord from BBU to the Adit 3500 (2 pin connect or).
Adit 3500 - Release 1.6 15 Quick Start Guide Installation #2 Adit 3500 and Battery Backup mounted to the wall This method requires a more wall space. Note: This installation will require a minimum of wall space of: 17" (H) x 14" (W) x 2.5" (D).
16 Adit 3500 - Relea se 1.6 Quick Start Guide Chassis Overview Adit 3500 Battery B ackup Power Connector The following cable, is ha rd wired to the A dit 3500 Bat tery Backup a nd connects th e Adit 350 0. Chassis Overview The following illustrations show a ll connectors on the Adit 3500.
Adit 3500 - Release 1.6 17 Quick Start Guide Interface Connectors Interface Connectors The following are the Adit 3500 interface connectors: Note: The following is de pendant upon how the syst em (hardware) is configured. Systems can be ordered with/witho ut FXS, and can have from 1-4 DS1 ports.
18 Adit 3500 - Relea se 1.6 Quick Start Guide Interface Connectors 12 VAC Power Connection The Adit 3500 is powered by a 12 VAC Power Co nverter, which provides 12 VDC to the unit. Battery Connection The Battery connector on the Adit 3500 is a 2 pin connector provided specifically for the Battery Backup option.
Adit 3500 - Release 1.6 19 Quick Start Guide Interface Connectors DS1/E1 Connection Ports Each DS1/E1 connec tion port is equipped with a standard RJ-4 8C (female) on the Adit 3500 unit.
20 Adit 3500 - Relea se 1.6 Quick Start Guide Interface Connectors 10/100Base-TX Ethernet The 10/100Base-TX Ethernet (female) port s provide connectivity for Router WAN and/or LAN ports and for mana gement co nnection via Telnet and /or SNMP to a Network Management System.
Adit 3500 - Release 1.6 21 Quick Start Guide Reset Button RS-232 Craft Port (Female DB-9) The RS-232 craft port connector (female) is for co nnection to an external PC or Hayes-compatible modem for local or remote conf iguration, management , and performance monitoring using t he Adit 3500 Command Line Interface (CLI).
22 Adit 3500 - Relea se 1.6 Quick Start Guide Alarm/Status LEDs Alarm/Status LEDs LED State Description Critical Off No critical alarms present Red Critical alarms present. Critical alarms include : user-configured manor enviro nmental inputs. Major Off No major alarms present Red Major alarm present.
Adit 3500 - Release 1.6 23 Quick Start Guide Web-Based Management Web-Based Management The web-based mana gement interface allows you to control various system parameters. The interface is accessed through a web browser. To access the management console: NOTE: The following assumes that you have connected the PC to the LAN port of the Adit 3500.
24 Adit 3500 - Relea se 1.6 Quick Start Guide Setting up a CLI Connecti on Setting up a CLI Connection A CLI connection will require t he LAN or WAN IP ad dress of the unit.
Adit 3500 - Release 1.6 25 Quick Start Guide Log in Log in After successful connection, via telnet or HyperT erm, the user must login. Default Logins are: Login: admin Password: admin123 After successful login the prompt will be displayed as follows: Adit 3500> NOTE: It is recommended that you cha nge your password from the default.
26 Adit 3500 - Relea se 1.6 Quick Start Guide Key Enabled Software Features This information is also displayed with the following CLI command: Adit 3500> show version Application Version: 1.5.0 Compilation Time: Thu Jun 14 2007 18 :07:22 FPGA Version: 1.
Adit 3500 - Release 1.6 27 Quick Start Guide Basic Configuration Basic Configuration The following configuration is divided into logical sections, where each section configures an additional function. The first must be configured before the second and so forth, ho wever, you may stop at any section and not add the following feat ure.
28 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration Restore Factory Defaults If the unit is not out-of-the-box , you may want to verify t hat the unit is set to defaults. Note: this will reset the IP address back to the default settin g of 192.
Adit 3500 - Release 1.6 29 Quick Start Guide Basic Configuration Modify Default Admin User For security purposes it is recommended that the Ad ministrator User be change d from the default settings.
30 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration z Modify the User info rmation, and select OK to save. It is important t o note that you need to have a minimum of on e user with Administrative Privileges . For users with other access levels, use the New User to add additional users on the system.
Adit 3500 - Release 1.6 31 Quick Start Guide Basic Configuration Configure WAN Interface fo r Internet Connectivity There are options to this WAN configuration.
32 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration 3. Select the Settings button. 4. Set the proper Framing Type and Line Coding. 5. Select OK to apply the new settings and exit this window. 6. Select OK again to return to the Network Connections window.
Adit 3500 - Release 1.6 33 Quick Start Guide Basic Configuration 7. Select (click) the Serial 1 connectio n. 8. Select the Settings button..
34 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration 9. Set the following on the Configure Serial 1 window: - Network Type to WAN (this is the default setting) - PPP Authentication to your required preferences 10. Select OK to apply the new sett ings and exit this window.
Adit 3500 - Release 1.6 35 Quick Start Guide Basic Configuration Multiple T1s (Multilink) To configure Multiple T1s utilizing Multilink PPP: 1. Select Network Connections from the Navigation bar. 2. Select (click) a T1 Interface (from T1 1 - T1 4) to configure.
36 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration 4. Set the proper Framing Type and Line Coding. 5. Select OK to apply the new settings and exit this window. 6. Select OK again to return to the Network Connections window. 7. Repeat steps #1-6 for additiona l T1s required for the ML-PPP 8.
Adit 3500 - Release 1.6 37 Quick Start Guide Basic Configuration 9. Select (click) New Connection to create the ML-PPP connection. 10. Select the Multilink Point-to-Point Protocol over DS0 (Multilink ) , and select Next .
38 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration 11. Enter User Name and Password . 12. Select the T1s for this Multilink and the channel ranges. 13. Select Next . 14. A summary of the Multilink connection will be displayed. If correct, select Finish .
Adit 3500 - Release 1.6 39 Quick Start Guide Basic Configuration 15. The new Multilink connection will di sp lay on the Network Connections window. 16.
40 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration 18. Set the following on the Configure Multilink 1 win dow: - Network Type to WAN (this is the default setting) - PPP Authentication to your required preferences 19. Select OK to apply the new sett ings and exit this window.
Adit 3500 - Release 1.6 41 Quick Start Guide Basic Configuration Ethernet WAN To configure the WAN utilizing Ethernet feed: 1. Select Network Connections from the Navigation bar. 2. Select (click) the delete icon associated with the Serial 1 connection.
42 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration 4. Select the Enable button, to configure the WAN Ethernet up (or in-service). 5. Select the Settings button. 6. Set Network type to WAN . 7. Set Internet Protocol option (method of IP address assignment).
Adit 3500 - Release 1.6 43 Quick Start Guide Basic Configuration Configure the Adit 3 500 as a SIP Gateway 1. Select Voice Over IP from the Navigation bar.
44 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration 2. On the IP Telephony tab, under Proxy Servers : - Set Proxy Type to Generic/custom (BroadSo ft or Sylantro). Example: BroadSoft - Select Use SIP Proxy and enter SIP Proxy IP address - Select supported Codecs 3.
Adit 3500 - Release 1.6 45 Quick Start Guide Basic Configuration 5. Modify any advanced VoIP settings as needed and select Apply. 6. Select OK to exit window.
46 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration 7. If using the FXS ports, select the Phone Settings tab. 8. Select the Action icon on line #1 to edit.
Adit 3500 - Release 1.6 47 Quick Start Guide Basic Configuration 9. Enter the Phone Number in the User ID field. 10. Enter Authentication information as needed . 11. Select OK to apply and exit this window. 12. Select OK to acknowledge that with these ch anges, active calls will be dropped.
48 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration 14. The current User ID of the FXS lines will di splay. 15. Select the Line Monitoring tab. This window displays the S IP status of the FXS ports. Note: When a telephone port is successfully regi stered the Registration Status column displays "Registered" in green.
Adit 3500 - Release 1.6 49 Quick Start Guide Basic Configuration 19. Set the Signaling Type . 20. Select New Entry to assign numbers to your PRI interface(s).
50 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration 21. Enter the phone number range for numbers to be routed to the trunk interface for incoming SIP calls, on the Call Destination window. Use Strip and Prefix entries to translate the incoming destination number from SIP to the destination number to be sent to the PRI/CAS interface.
Adit 3500 - Release 1.6 51 Quick Start Guide Basic Configuration 24. Select the Trunk Monitoring tab to view the status of any calls on the PRI..
52 Adit 3500 - Relea se 1.6 Quick Start Guide Basic Configuration.
デバイスCarrier Access Adit 3500の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Carrier Access Adit 3500をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCarrier Access Adit 3500の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Carrier Access Adit 3500の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Carrier Access Adit 3500で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Carrier Access Adit 3500を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCarrier Access Adit 3500の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Carrier Access Adit 3500に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCarrier Access Adit 3500デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。