Carverメーカーpm125の使用説明書/サービス説明書
ページ先へ移動 of 20
DECLARATION OF CONFORMITY We PHOENIX GOLD INTERNATIONAL, INC. (supplier ’ s name) 9300 N. DECATUR, PORTLAND, OR 97203 USA (address) declare under our sole responsibility that the product pm125 / 420.
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL T.
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL T.
pm125 7 6 • 50W per channel into 8 ohms 62W per channel into 4 ohms 125W mono into 8 ohms • 1/4-inch TRS input jacks • Accepts balanced or unbalanced lines • Multi-way binding post output conn.
pm125 7 6 • 50W per channel into 8 ohms 62W per channel into 4 ohms 125W mono into 8 ohms • 1/4-inch TRS input jacks • Accepts balanced or unbalanced lines • Multi-way binding post output conn.
Continuous Average Output Power, both channels driven: 135 watts per channel into 8 ohms from 20Hz to 20kHz, with no more than 0.1% THD 210 watts per channel into 4 ohms at 1kHz, with no more than 0.1% THD Bridged-mono operation: 420 watts into 8 ohms at 1kHz, with no more than 0.
Continuous Average Output Power, both channels driven: 135 watts per channel into 8 ohms from 20Hz to 20kHz, with no more than 0.1% THD 210 watts per channel into 4 ohms at 1kHz, with no more than 0.1% THD Bridged-mono operation: 420 watts into 8 ohms at 1kHz, with no more than 0.
5. CH1 / CH2 LEVEL CONTROLS These controls are used to adjust the input level of each channel. When the controls are fully clockwise the amplifier operates at maximum gain.
5. CH1 / CH2 LEVEL CONTROLS These controls are used to adjust the input level of each channel. When the controls are fully clockwise the amplifier operates at maximum gain.
AC Power Considerations Ensure that the pm125 or pm420 is plugged into an outlet capable of supplying the correct voltage specified for your model and enough current to allow full-power operation of all the amplifiers plugged into it.
AC Power Considerations Ensure that the pm125 or pm420 is plugged into an outlet capable of supplying the correct voltage specified for your model and enough current to allow full-power operation of all the amplifiers plugged into it.
CAUTION ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. WARNING: 120 VAC 50-60 Hz 1000 WATTS CLASS II WIRING MAY BE USED.
CAUTION ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. WARNING: 120 VAC 50-60 Hz 1000 WATTS CLASS II WIRING MAY BE USED.
C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER TO ACTIVATE THE CH2 CLIPPING ELIMINATOR STEREO/MONO SWITCH CH2 LEVEL BYPASS CH1 LEVEL BYPASS ADD THIS JUMPER TO ACTIVATE THE CH1 CLI.
C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER TO ACTIVATE THE CH2 CLIPPING ELIMINATOR STEREO/MONO SWITCH CH2 LEVEL BYPASS CH1 LEVEL BYPASS ADD THIS JUMPER TO ACTIVATE THE CH1 CLI.
C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 BACK OF AMPLIFIER 19 18 Figure 9 In Case of .
C37 P3 P4 14 J14 P5 P6 2 1 RP2 J15 J16 RP1 J1 U5 U4 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 ADD THIS JUMPER FOR 0.775V INPUT SENSITIVITY IN CH2 BACK OF AMPLIFIER 19 18 Figure 9 In Case of .
Notes W arranty Informa tion Professional Power Amplifiers: 5 years WHA T IS COVERED: THIS W ARRANTY COVERS DEFECTS IN MATERIAL AND WORKMANSHIP ONL Y. This limited W arranty DOES NOT extend to: 1) Dam.
Notes W arranty Informa tion Professional Power Amplifiers: 5 years WHA T IS COVERED: THIS W ARRANTY COVERS DEFECTS IN MATERIAL AND WORKMANSHIP ONL Y. This limited W arranty DOES NOT extend to: 1) Dam.
DECLARATION OF CONFORMITY We PHOENIX GOLD INTERNATIONAL, INC. (supplier ’ s name) 9300 N. DECATUR, PORTLAND, OR 97203 USA (address) declare under our sole responsibility that the product pm125 / 420.
デバイスCarver pm125の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Carver pm125をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCarver pm125の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Carver pm125の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Carver pm125で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Carver pm125を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCarver pm125の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Carver pm125に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCarver pm125デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。