Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshir e • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www .cda.eu Passionate about style Manual for Inst allation, Use and Maintenanc e 0220 HCG500 HCG520 Manual.
Important The CDA Gr oup Ltd cannot be held r esponsible for injuries or losses caused by incorr ect use or installation of this product. Please note that CDA reserv e the right to invalidate the guarant ee supplied with this product following incorr ect installation or misuse of the appliance or use in a commer cial envir onment.
Using your hob Fig. 1 2 3 1 4 5 6 7 8 Gas burners: 1 . Rapid burner 3.0kW 2. Left Semi-Rapid burner 1 .75kW 3. Right Semi-Rapid burner 1 .75kW 4. Auxiliary burner 1 .0kW Contr ol panel: 5. Right Semi-Rapid burner contr ol knob 6. Left Semi-Rapid burner c ontrol knob 7 .
Igniting the Burners T o ignite the burner s, follo w these instructions: 1 . Lightly press the control knob (shown on the right) and turn the knob anti- clockwise to the maximum position. Pr ess and hold the control down t o begin the igni tion pr ocess (a cli cking sound will be hear d).
T otal rated gas input : 7 .5kW Mains electrical voltage: 230 – 240V ac T otal rated electrical consumption: <1W If your Hob is not w orking 1 . Check that the mains supply has not been swit ched off. 2. Check that the fuse in the spur has not blown.
DOUBLE POLE SWIT CHED FUSE SPUR OUTLET USE A 3 AMP FUSE Mains Electricity Connection THIS APPLIANCE MUST BE C ONNECTED T O THE MAINS SUPPL Y BY A CO MPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWIT CHED FUSE SPUR OUTLET AND PRO TECTED BY A 3A FUSE.
Gas Supply Requir ements IMPOR T ANT : THIS APPLIANCE SHOULD BE FITTED BY A GAS S AFE REGIS TERED FITTER OR O THER SUIT ABL Y QUALIFIED PERSON. • This inst allation must comply with the Gas Safety (installation and use) R egulations 1 984. • This appliance is cat egory II2H3+ and is designed for use in the UK and Ir eland.
Natur al Gas to LPG Con v ersion This hob can be converted from natural gas to pr opane operation at a nominal inlet pressure of 37mbar , or butane operation at a nominal inlet pressur e of 28/30mbar . This conver sion must only be carried out by a competent person (i.
Fitting the Hob Unpacking the hob: T ake care not to lose or mishandle an y parts. Fitting position of the hob: adjacent vertical surfaces, e.g. a t all cupboar d end panel. This ma y be reduced to 1 00mm if the adjac ent surfac e is resistant to fir e (tiles or steel, for example).
How t o install the hob: Overall dimensions of the hob: Width: 585mm Depth: 500mm W orktop cut-out dimensions: Width: 550mm Depth: 470mm 1 . Make the requir ed hole in the worktop. Befor e doing this, you must check the instructions supplied with any cooker hood to ensure that you will have the requir ed clearance.
Not es : 0220 HCG500 HCG520 Manual.indd 11 26/6/09 09:35:51.
Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshir e • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www .cda.eu Passionate about style T o contact our Customer Car e Department, or for Service, please contact us on the det ails below .
デバイスCDA HCG501WHの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
CDA HCG501WHをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCDA HCG501WHの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。CDA HCG501WHの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。CDA HCG501WHで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
CDA HCG501WHを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCDA HCG501WHの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、CDA HCG501WHに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCDA HCG501WHデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。