Customer Care Department • The Group Ltd. • Harby R oad • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .
2 Important The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that we reserve the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance.
3 safety (L VD) and Electromagnetic interference compatibility (EMC). Parts intended to come into contact with food conform to EEC/89/109 . IMPORT ANT INFORMA TION FOR CORRECT DISPOSAL OF THE PRODUCT IN A CCORD ANCE WITH EC DIRECTIVE 2002/96/EC.
4 • This hob (Class 3) has been designed for use only as a cooking appliance. Any other use (e. g. heating rooms) should be considered incorrect and potentially dangerous. • These instructions are valid only for the countries of destination, the symbols of which appear on the cover and on the appliance.
5 Using Y our Hob Fig. 1 Gas burners: Gas flow to the burners is controlled by the control knobs (5, 6, 7 and 8 on the diagrams on pages 6 & 7). There are 3 positions shown on the control panel.
6 g hg6300 Fig. 2 hg6310 Fig. 3 3 3 3 3 2 1 4 4 5 6 7 8 5 6 7 8.
7 K ey to Figs 2, 3 & 4 Gas burners: 1. T riple burner 3.5k W 2. R apid burner 3. 0k W 3. Semi-Rapid burner 1. 75k W 4. Auxiliary burner 1. 0k W Control panel: 5. Front left burner control knob 6. Back left burner control knob 7 . Back right burner control knob 8.
8 Igniting the Burners The hob is fitted with a flame failure device. Flame failure devices operate by shutting o the supply of gas to the burner in the event that the flame is extinguished accidentally . T o ignite the burners, follow these instructions: 1.
9 Fig. 6 Ecient Use of Y our Hob The hob is equipped with burners of dierent sizes, designed to accommodate most shapes and sizes of pan. For best results, only use pans with flat bottoms and choose an appropriate burner depending on the size of the pan.
10 Correct Use of the Optional W ok P an Adaptor (hg6310 & hg6320 only) The wok pan adaptor is a special stand that is designed to be fitted over the triple ring burner to give support to round bottomed woks. When using a wok, always place the wok pan adaptor in position over the pan support on the triple ring burner as shown in Fig.
11 Care and Maintenence As the hob has a stainless steel or enamel surface, you should use a nonabrasive cleaner . Any abrasive cleaner (including Cif ) will scratch the surface and could erase the control panel markings.
12 T otal rated gas input : 7 .5kW (hg6300) 8. 0kW (hg6310 & hg6320) Mains electrical voltage: 230 – 240V ac, 50Hz T otal rated electrical consumption: <1W If Y our Hob is Not W orking 1. Check that the mains supply has not been switched o .
13 Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED T O THE MAINS SUPPL Y B Y A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWIT CHED FUSE SPUR OUTLET AND PROTECTED B Y A 3A FUSE. W e recommend that the appliance is connected by a qualified electrician, who is a member of the N.
14 Gas Supply R equirements IMPORT ANT : THIS APPLIANCE SHOULD BE FITTED B Y A GAS SAFE REGIS TERED FITTER OR OTHER SUIT ABL Y QU ALIFIED PERSON. • ThisinstallationmustcomplywiththeGasSafety(installationand use) R egulations 1984.
15 Room V olume (m 3 ) 5 6 to 10 6 to 11 11 or more Air V ent Required (cm 2 ) 100 50 No permanent vent required if a door opens to the outside None required V entilation All rooms require a window or equivalent (e.g. a door) which can be opened. Some rooms require a permanent vent in addition to a win- dow (see below).
16 Natural Gas to LPG Conversion This hob can be converted from natural gas to propane operation at a nominal inlet pressure of 37mbar , or butane operation at a nominal inlet pressure of 28/30mbar . This conversion must only be carried out by a competent person (i.
17 LPG to Natural Gas Conversion This hob can be converted from propane operation at a nominal inlet pressure of 37mbar or butane operation at a nominal inlet pressure of 28/30mbar to natural gas at 20mbar . This conversion must only be carried out by a competent person (i.
18 Fitting the Hob Unpacking the hob: T ake care not to lose or mishandle any parts. Fitting position of the hob: This appliance must be installed a minimum of 50mm from any back wall and a minimum of 150mm away from any adjacent vertical surfaces, e.
19 Fig. 11 15mm V entilation slot > 30mm withstanding temperatures 65°C above ambient or greater (typically 80-90°C). • If there is no oven to be built in below the hob it is recommended that, an isolation shelf should be fitted to protect the user from high temperatures.
20 2. Position the hob seal, as shown in the diagram below (Fig. 14), ensur - ing that the ends meet without overlapping. Do not use silicone type sealant. 3. Secure the hob to the worktop using the fixing brackets and screws supplied, as shown in the following diagram (Fig.
21 NO TES:.
22 NO TES:.
23 E & O E. All instructions, dimensions and illustrations are provided for guidance only . CDA reserve the right to change specifications without prior notice.
Please contact our Customer Care Department for Service on the details below Customer Care Department • The Group Ltd. • Harby R oad • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .care@cda.eu W : www.
デバイスCDA HG6310の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
CDA HG6310をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCDA HG6310の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。CDA HG6310の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。CDA HG6310で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
CDA HG6310を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCDA HG6310の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、CDA HG6310に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCDA HG6310デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。