CDAメーカーHVG66の使用説明書/サービス説明書
ページ先へ移動 of 20
Customer Car e Department • T he Group Ltd. • Harb y Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.
2 Impor tant This appliance is designed and manufactured solely f or the cooking of domestic (household) food and is not suitable for any non domestic application and therefor e should not be used in a commercial environment. The appliance guarantee will be v oid if the appliance is used within a non domestic environmen t i.
3 Impor tant Safeguards and Rec ommendations – Do not carr y out any cleaning or maintenance without rst disc onnecting the appliance from the electrical supply. – During and after use of the hob, certain parts will become ver y hot. Do not touch hot parts.
4 F eatures and T echnical Data 4 5 6 7 1 2 2 3 Cooking P oints 1. Auxiliary burner (A) 1,00 kW 2. Semi-rapid burner (SR) 1,75 kW 3. Rapid burner (R) 3,00 kW Contr ol Panel 4. Auxiliary burner control knob (1) 5. Rapid burner control knob (3) 6. Rear right semi-rapid burner control knob (2) 7.
5 How to U se the Hob Gas Burners Gas ow to the burners is adjusted by turning the knobs (illustrated in g. 2) which contr ol the valves. T urning the knob so that the indicator line points to t.
6 Choice of Burner The symbols printed on the panel by the side of the knob indicate which burner you are c ontrolling. Choose a suitable burner depending on the cookware dia - meter and capacity . The pan diameter should be suitable for the burner pow er to make the most of the burner ’ s high eciency and not waste fuel.
7 Cleaning and Maintenanc e General Tips – Before cleaning the hob switch it o and wait f or it to cool down. – Clean with a cloth, hot water and soap or liquid detergen t. – Do not use products which are abrasive, c orrosive or chlorine based.
8 Burners and Grids – These parts can be removed and cleaned with appropriate pr oducts. – After cleaning, the burners and their ame spreaders must be w ell dried and correctly replaced. – It is very impor tant to check that the burner ame spreader and the cap have been correctly positio - ned.
9 F C Flame failure probe “ T ” Ignitor “ S ” Correct P ositioning of the Auxiliary , S emi-rapid and Rapid Burners – It is very impor tant to check that the burner ame spreader “ F ” and the cap “ C ” have been correctly positioned (see gs.
10 TIPS FOR INST ALLA TION Location – The appliance may be installed in a kitchen, Kitchen/diner or a bed sitting room, but not in a room or space containing a bath or a show er . – The appliance must not be installed in a bed-sitting room of less than 20m 3 .
11 Installation T echnical Information For The Installer In order to install the cooktop into the kitchen xture, a hole with the dimensions sho wn in g. 10 has to be made, bearing in mind the follo wing: – Within the unit, between the bottom of the c ooktop and the upper surface of a shelf there must be a clearance of at least 30mm.
12 Installing the Separator Below the Base of the Cooktop It is recommended that a 30mm clearance be left between to base of the cooktop and the separat or . The separator shall be heat r esistant, made of low thermal conductivity material and shall be remova - ble with the use of a tool for installation and ser - vice.
13 F astening the C ooktop Each cooktop is provided with an installa tion kit including brackets and screws for fastening the co - oktop to benches from 30 to 40mm thick.
14 Gas Supply Requirements Important Note This appliance is supplied for use on NA TURAL GAS or LPG (check the gas regulation label attached on the appliance). – Appliances supplied for use on NA TURAL GAS: they are adjusted for this gas only and cannot be used on any other gas (LPG) without modication.
15 Gas Connection The installation of the gas appliance to Natur al Gas or LP Gas must be carried out by a suitably quali - ed and registered installer .
16 Gas Connection GB Cat: II 2H3+ The tting (g. 20) is made up of: – 1 nut “ A ” – 1 elbow tting “ C” – gasket “ F ” Connection to the Gas Supply • Be careful when exible pipes are used that they do not come into contact with moving parts.
17 Con version to Natur al Gas or to LPG Replacing the Burner Injectors If the NA TURAL GAS/LPG conversion kit is not supplied with the appliance this kit can be purchased by contacting the After-Sales Service. Choose the injectors to be replaced accor ding to the “ T able for the Choice of the Injectors” .
18 T able for the Choice of the Injectors GB Cat: II 2H3+ Burners Nominal Powe r kW Reduced Powe r kW G30 - 28-30 mbar G31 - 37 mbar G20 - 20 mbar Ø Injector 1/100 mm Ø Injector 1/100 mm Auxiliary (.
19 Mains Elec tricity Connection Incorrect installation may be dangerous and the manufacturer can not be held responsible. W arning! This appliance must be ear thed The manufac turer declines all responsibility for any problem caused by failure to observe this rule .
Appliance Servicing CDA provide a quality and e ective after-sales service to cover all your servicing needs. Please attach your rec eipt to this page for safekeeping . Please help us to help you by ha ving the following inf ormation available when booking a ser vice- call: 1.
デバイスCDA HVG66の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
CDA HVG66をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCDA HVG66の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。CDA HVG66の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。CDA HVG66で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
CDA HVG66を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCDA HVG66の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、CDA HVG66に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCDA HVG66デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。