1 OWNER'S MANUAL MODEL SL920 COMMERCIAL SLIDE GA TE OPERA T OR 2 YEAR WARRANTY Serial # _____________________ (located on electrical box cover) Installation Date:_______________ SL920 GATE OPERATORS ARE FOR USE ON VEHICULAR PASSAGES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
2 General Information.................................................................................................................3, 4 Features........................................................................................................
3 General Information BASE PLATE HOLE PATTERN OVERALL DIMENSIONS: Height: 21" Length: 12" Width: 17" SHIPPING WEIGHT : 125 lbs.
4 CIRCUIT BOARD: The SL920 uses the Full Systems Capability circuit board, a powerful control system. This circuit board operates on 12 ~ 18 Volts and can deliver power to the motor through high power switching. The limit switch input terminals require the use of normally open type limit switches.
5 Features OPERA TION The SL920 Full Systems Capability can operate in a AUTO CLOSE TIMER (TIMER ON) or a PUSH-TO-OPEN/PUSH-TO-CLOSE (TIMER OFF) mode of operation.
6 Part s Identification.
7 Parts Identification continued... K72-30359 SERVICE KIT K74-40045 SERVICE KIT LIMIT/DRIVE SHAFT ASSEMBLY PCB GUARD AND STANDOFF ITEM DESCRIPTION QTY DESCRIPTION QTY PART # DESCRIPTION QTY LIMIT/DRIV.
8 Remove the gate operator from it's package and make sure that all parts are included. Refer to General Information and Parts Identification. If any parts appear to be missing, contact dealer. Temporarily plug the operator into 115 Volt outlet or extension cord.
9 Installation continued... Disconnect Power from the gate operator! The tail end of the gate should extend approximately 24" beyond the edge of the driveway. If this is not the case, an extension tail will need to be added to the gate. This will give room for the gate operator.
10 Installation Continued... If the steel mounting stand was used, simply bolt the gate operator to the stand. If the operator will be mounted to a concrete surface or pad, place the shortest edge of the operator 4" away from the edge of the driveway.
11 Installation Continued... Attach the gate bracket to the gate as shown using the round or square u-bolts for round or square gate frames respectively. Attach the chain to the gate brackets using the chain bolt and master link as shown. If necessary, the chain may be easily short- ened using a chain breaker.
12 Alternate Inst allations The rear mount installation is an excellent way to conceal the chain or opera- tor. The operator is placed in the extreme rear of the gate as shown and the chain never goes across the driveway. The chain only goes from the gate operator to a post or wall beside the driveway.
13 Electrical Make sure that power is OFF before making any electrical connections! Be sure that all wiring is employed as required by local codes.
14 Electrical Continued... If the gate operator is already factory equipped with battery run, only the Right/Left Side switch and the Mode switch need to be set. The Right/Left switch simply needs to be set in the same position as the Right/Left switch on the main control board.
15 GRY GRY 1 2 3 4 BLK RED S AFETY N.O . N.O . N.O . N.C. N.O . N.O . OPEN PULSE OPEN N.C.STOP CL OSE N.O .STOP 412 HM RADIO RECEIVER ) ) ) ) ) ) REMOVE JUMPER IF USING N .
16 Wiring Diagrams, Button Controls z One button, two button and three button controls may be connected individually or together as shown below. Most button controls have a common "buss bar" which connects the common terminals of all buttons together so that only one common wire needs to be run back to the gate operator control board.
17 Fine T uning The gate operator is designed to work differently while opening then while closing to optimize safety, so the direction of the operator will need to be set. Setting the operator direction is done by flipping the right/ left side switch located at the top of the circuit board.
18 z Connect 115 Volts AC to each SL920 gate operator. Connect the four Master/Second wires from the master circuit board to the Second circuit board as shown below. Any operator can be used as either a master or a Second. Accessories can be connected to the master or second operator.
19 Wiring Diagram SL920 WITH FULL SYSTEMS CAPABILITY.
20 Wiring Diagrams SL920 WITH BATTERY BACK-UP BREAKER 15 AMP.
21 Safety Edge and W arning Placard Inst allation See reversing edge sensor instructions for the exact placement of the reversing edge contact sensors. One or more safety edge contact sensors shall be located at the leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate.
22 Options If it is desired that the driveway illuminate when the gate is activated, a light delay timer may be installed. The light delay timer will switch power on to the light for two minutes, then shut power back off. The timer relay is capable of switching up to 10 Amps which will handle most flood or spot lights available.
23 For rear mount installation that are limited on space for the gate to slide back into, the space saver version is an excellent alternative. There may be a property wall, parking stall or other obstacle that reduces the amount of space available, making it difficult to mount the gate operator and still have room for the gate to slide.
24 Gate Hardware Locator Options Continued....
25 The SL920 is designed to be MAINTENANCE FREE. However, for optimum performance and safety, the following maintenance procedures should be taken. IMPORT ANT SAFETY INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1) READ AND FOLLOW ALL INSTRUCTIONS 2) Never let children operate or play with gate controls.
26 T roubleshooting EXPLANATION OF VISUAL FEEDBACK LEDs The SL920 Full Systems Capability circuit board has been equipped with Visual Feedback LEDs to simplify installation and troubleshooting. These are small lights which are located directly beside the input terminals.
27 Troubleshooting GATE WILL NOT OPEN OR CLOSE Test the operator to find out whether the open input devices are functioning by following these steps. n n n n n If a remote control is being used to open the gate, try another remote control or try using a push button if there is one installed.
28 NOTE: z All open and safety devices must have normally open contacts. z For Devices requiring power, refer to the specific diagram for that particular device. Notes Other Commonly Used Open and Safety Devices Be sure to read this entire manual before attempting to perform any type of installation or service to the gate opener.
29 Notes Be sure to read this entire manual before attempting to perform any type of installation or service to the gate opener. Once the installation has been completed, this installation and service manual becomes the property of the home owner or end user and should be given to the new owner at that time.
30 Notes.
31 Notes.
32 W ARNING To reduce the risk of injury use this operator only with a sliding gate that is no larger than 25 ft. in length and no heavier than 500 lbs. WHEN ORDERING REP AIR P ARTS PLEASE SUPPL Y THE FOLLOWING INFORMA TION: P ART NUMBER DESCRIPTION MODEL NUMBER ADDRESS ORDER TO: THE CHAMBERLAIN GROUP , INC.
デバイスChamberlain SL920の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Chamberlain SL920をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはChamberlain SL920の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Chamberlain SL920の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Chamberlain SL920で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Chamberlain SL920を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はChamberlain SL920の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Chamberlain SL920に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちChamberlain SL920デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。