ChromaloxメーカーPF490-5の使用説明書/サービス説明書
ページ先へ移動 of 12
Ch ro m alox ® DIVISION 4 SECTION CXH-A SALES REFERENCE DATE SERVICE REFERENCE PF490-5 161-302421-004 JULY, 2004 Installation Instructions and RENEWAL PARTS IDENTIFICATION (Supersedes PF490-4) © 2010 Chromalox, Inc. For ced Air Heater for Hazar dous Locations Overall Dimensions 5/8” UNC Tapped Horiz.
W ARNING Failure to understand and follow these installation instructions and the WARNING notes contained therein may result in severe personal injury, death or substantial property damage.
3 The heaters may be mounted at any convenient height above floor. The minimum spacings shown in Figure 4 should be main- tained to adjacent walls and ceiling.
4 MOUNTING KITS Figure 5 Figure 7 Figure 9 Figure 6 Figure 10 Wall Mount Kit Model # WMB-12 12” Fan (3-10 kW) Model # WMB-16 16” Fan (15-20 kW) Model # WMB-20 20” Fan (25-35 kW) Pole or Wall Mou.
5 WIRING AND WIRING DIAGRAMS ELECTRIC SHOCK HAZARD. Disconnect all power before installing or servicing heater. Failure to do so could result in personal injury or property damage. Heater must be installed by a qualified person in accor- dance with the National Electrical Code, NFPA 70.
6 WIRING DIAGRAMS DIAGRAM I DIAGRAM II Refer to Name Plate for Input Voltage Optional Disconnect Switch 1PH L1 L2 GND C1 Elements H1 H2 X1 X2 Refer to Nameplate for T ransformer Voltage Motor T3 T2 Bu.
7 OPERA TION EXPLOSION HAZARD. Heater should not be operated in ambient temperature higher than 40˚C (104˚F) or in atmospheres corrosive to the heater itself.
MAINTENANCE AND REP AIR The occurrence of the manual reset limit control to trip is an abnormal condition. Care should be taken to determine the exact reason that the high limit control tripped.
MAINTENANCE AND REP AIR 1. CONTROL TRANSFORMER This item is located in the electrical enclosure. It may be replaced while in the enclosure. To service or replace remove the quick connect wires and mark their locations. Remove two screws which hold the transformer in place.
RENEW AL P ARTS IDENTIFICA TION 10 T ransformer Contactor Figure 16 1 33 35 50 19 15 17 16 31 34 52 51 32 25 30 26 44 27 28 29 75 50 27 15 6 62 10 CO 8 12 9 49 15 Figure 17 Electrical Control Voltage .
11 MANUFACTURER PART NUMBER BREAKDOWN (LOCATED ON UNIT NAMEPLATE) Code CXH-A-03 CXH-A-15, CXH-A-25, 05, 07 & 10 18 & 20 30 & 35 Item# Description Part No.
2150 N. RULON WHITE BLVD., OGDEN, UT 84404 Phone: 1-800-368-2493 www.chromalox.com Limited Warranty: Please refer to the Chromalox limited warranty applicable to this product at http://www.
デバイスChromalox PF490-5の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Chromalox PF490-5をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはChromalox PF490-5の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Chromalox PF490-5の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Chromalox PF490-5で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Chromalox PF490-5を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はChromalox PF490-5の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Chromalox PF490-5に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちChromalox PF490-5デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。