Comments to ucs-doc feedbac k@cisco.com Americas Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA Cisco UCS B230 Blade Server Installation and Service Note The Cis.
Comments to ucs-doc feedbac k@cisco.com 2 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 operating expen s es. Among the I/O adapter options, and un ique to the Cisco Unified C.
Comments to ucs-doc feedbac k@cisco.com 3 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01 the server to become out of sync with the actual po we r state and the s erver may une xpected shutdo wn at a later time. T o safely reboot a se rv er from a power -down state, use the Boot Server action in Cisco UCS Manager .
Comments to ucs-doc feedbac k@cisco.com 4 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Each UCS B230 blade serv er contains sev eral Field Replaceable and Field Upgradab le u.
Comments to ucs-doc feedbac k@cisco.com 5 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01 Safety warnings appear th roughout this publication in procedures th at, if performed incorrectly , can cause physical injuries. A warning sy mbol precedes eac h warning statement.
Comments to ucs-doc feedbac k@cisco.com 6 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol b edeutet Gefahr . Sie befinden sich in einer Situation, die zu V erletzungen führen kann.
Comments to ucs-doc feedbac k@cisco.com 7 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01 Va r n i n g ! VIKTIGA SÄKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada.
Comments to ucs-doc feedbac k@cisco.com 8 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Avis o INSTRUÇÕES IMPORT ANTES DE SEGURANÇA Este símbolo de aviso significa perigo. V ocê se encontra em uma situação em que há risco de lesões corporais.
Comments to ucs-doc feedbac k@cisco.com 9 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01.
Comments to ucs-doc feedbac k@cisco.com 10 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Installing and Removing a Solid State Drive Installing and Removing a Solid State Drive There are up to 2 front-accessible, hot-swappable SSD driv es per blade.
Comments to ucs-doc feedbac k@cisco.com 11 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01 Installing and Removing a Solid State Drive Caution T o pre vent ESD damage, wear grounding wrist st raps during these procedures and handle mo dules by the carrier edges only .
Comments to ucs-doc feedbac k@cisco.com 12 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Removing and Installing a UCS B230 Figure 3 Squeeze the Catc h on the Dr ive Sled Step 3 Place the dri ve on an antistatic mat or antistatic foam if you are not immediately reinstalling it i n another blade server .
Comments to ucs-doc feedbac k@cisco.com 13 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01 Removing and Installing a UCS B230 • Standb y power mode—Po wer is supplied only to the service processor an d the cooling fans and it is safe to remove the server for service.
Comments to ucs-doc feedbac k@cisco.com 14 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Removing and Installing a UCS B230 Installing a Cisco UCS B230 Blade Server T o instal l a blade server , follo w these steps: Step 1 Grasp the front of t he blade server and place your other hand under the blade to support it.
Comments to ucs-doc feedbac k@cisco.com 15 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01 Removing a Blade Server Cover Removing a Blade Server Cover Caution T o pre vent ESD.
Comments to ucs-doc feedbac k@cisco.com 16 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Removing a Blade Server Cover Blade Server Internal Components Figure 6 calls out the various co mponents within the blade server .
Comments to ucs-doc feedbac k@cisco.com 17 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01 Working Inside th e Blade Server Working Inside the Blade Server This section descri.
Comments to ucs-doc feedbac k@cisco.com 18 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Working Inside the Blade Server Step 3 Unhook the socket latch. (See Figure 7 , cal lout 3.) Step 4 Open the so cket latch. (See Figure 7 , callout 4.
Comments to ucs-doc feedbac k@cisco.com 19 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01 Working Inside th e Blade Server In systems shipped wi th one CPU, the vacant CPU has an N20-BBFLA- 230 air blocker (see Figure 8 ) in place of the CPU heat sink.
Comments to ucs-doc feedbac k@cisco.com 20 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Working Inside the Blade Server Figur e 9 Inser ting the CPU and Replacing the Heat Sink Step 2 Close the so cket latch. (See Figure 9 , callo ut 2.
Comments to ucs-doc feedbac k@cisco.com 21 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01 Working Inside th e Blade Server Installing a Motherboard CMOS Battery The B230 blade serv er supports the follo wing Cisco component: War ni n g There is danger of explosion if the battery is replaced incorrectly .
Comments to ucs-doc feedbac k@cisco.com 22 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Working Inside the Blade Server Figur e 1 0 Removing and Replacin g a Mot herboard CMOS Bat tery Installing an Adapter Card The network adapters and interface cards a ll hav e a shared installation proces s.
Comments to ucs-doc feedbac k@cisco.com 23 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01 Working Inside th e Blade Server If you are swit ching from one type of adapter card.
Comments to ucs-doc feedbac k@cisco.com 24 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Memory and Perfo r mance Installing Memory Only the DIMMs listed in Ta b l e 6 should be used. Memory must be installed i n the order shown in Ta b l e 8 into the slots located in Figure 13 .
Comments to ucs-doc feedbac k@cisco.com 25 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01 Memory and Performance Supported DIMMs Ta b l e 6 lists the type of DIMM s that Cisc.
Comments to ucs-doc feedbac k@cisco.com 26 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Memory and Perfo r mance Figure 13 sho ws how DIMMs slots are laid out on the blad e server . A CPU uses the DIMM slots directly to the right or the left of the CPU.
Comments to ucs-doc feedbac k@cisco.com 27 Cisco UCS B230 Blade Server In stalla tion and Service No te OL-23811-01 Server Troublesh ooting Server Troubleshooting For general server troubleshooti ng information, re fer to t he " T r oubleshooting Server Har d war e " chapter of the Cisco UCS T rou bleshooting Guide .
Comments to ucs-doc feedbac k@cisco.com 28 Cisco UCS B230 Blade Server Insta llation and Service Note OL-23811-01 Related Documentation.
デバイスCisco Systems UCSEZB230EX256の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cisco Systems UCSEZB230EX256をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCisco Systems UCSEZB230EX256の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cisco Systems UCSEZB230EX256の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cisco Systems UCSEZB230EX256で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cisco Systems UCSEZB230EX256を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCisco Systems UCSEZB230EX256の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cisco Systems UCSEZB230EX256に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCisco Systems UCSEZB230EX256デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。