© 2003 ÂColeman Powermate, Inc. 12-03 S t ationary S t andby Electric Generator - 25,000 W A TTS I MPORT ANT SAFETY INSTRUCTIONS – Please make cert ain that persons who are to inst all, operate and maint ain this equipment thoroughly read and underst and these instructions prior to operation.
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Do not attempt to install the generator yourself. Extremely high and dangerous electrical voltages are present in utility power source lines and in generator load leads when the unit is running. Therefore, be sure to turn OFF all power voltage supplies at their source before attempting to complete electrical connections.
The National Electrical Code (NEC) requires the frame and external electrically conductive parts of the generator to be connected to an approved earth ground.
The stationary standby electric generator is manufactured for our customers to supply reliable backup power. The generator is a compact unit, designed to supply the power for your critical needs when utility power fails. The standby generator will run on Liquid Propane Gas or Natural Gas allowing flexibility for getting the power you need.
Rated W attage - (S tandby) 25,000 W atts@1.0PF LPG 22,000 W atts @ 1.0 PF NG V oltage - 120/240 volts Rated Current - 208/104 amps LPG Frequency - 60 HZ Power Factor - 1.0 Max. Ambient T emp Rise - 105°C Insulation class - H Note: Rated wattage is specified at sea level, 60°F ambient temperature, and prop ane fuel (with 2500 BTU/cuft).
I I N N S S T T A A L L L L A A T T I I O O N N D D R R A A W W I I N N G G S S 7.
NOTE: The generator frame has been designed with rectangular slots and frame tubes to be used with a forklift for removing the unit from the pallet and positioning the unit on the cement pad.
L L O O C C A A T T I I O O N N A A N N D D G G E E N N E E R R A A T T O O R R P P L L A A C C E E M M E E N N T T ( ( c c o o n n t t i i n n u u e e d d ) ) W W A A R R N N I I N N G G • For fire safety, the generator must be installed and maintained properly.
NATURAL GAS (NG) SETTINGS Units are tested with natural gas before they leave the factory. If natural gas is to be used, no adjustments are required. The fuel select switch, located on the bottom of the control panel, should be in the (NG) position.
This generator must be connected to an automatic transfer switch. The automatic transfer switch detects when a power failure occurs and automatically starts the engine to provide generator power. When the utility power becomes available, the transfer switch automatically shuts down the generator and switches back to the utility power.
Minimum recommended battery size is a BCI Group 26 with a minimum of 550 CCA (Cold Cranking Amps). Place the battery in the battery rack as shown and secure using the holddown hardware provided. Once the battery has been placed and tied down with the battery hold down bar, connect the leads to the respective battery post.
Check oil level before start-up. The unit is shipped with the proper type of oil in the crankcase for operation above 40°F. Follow the engine manufacturer’s recommendations for oil at temperatures below 40°F. Check oil periodically to ensure that the unit is properly lubricated.
A Two line by twenty character LCD provides the primary visual interface for metering, alarms, pre- alarms and protective functions. In the normal mode, labels appear above and below the display. In the alternate display mode, labels and the displayed value appear on the display.
DISPLAY MODE Pressing the Display/Toggle pushbutton allows the user to scroll through the Normal, Alternate and Menu display Modes. ALTERNATE DISPLAY MODE Alternate Display Mode can be used to observe.
When the generator control panel senses an abnormal operating condition, an alarm is declared and the generator set is shutdown. All alarm conditions will light a red LED (labeled Alarm ) along with displaying the condition on the LCD screen.
2 2 5 5 K K W W W W I I R R I I N N G G D D I I A A G G R R A A M M ( ( C C P P 5 5 0 0 0 0 C C O O N N T T R R O O L L L L E E R R ) ) SCHÉMA DE CÂBLAGE 25KW (CONTRÔLEUR CP 500) DIAGRAMA DE CIRCUI.
2 2 5 5 K K W W W W I I R R I I N N G G D D I I A A G G R R A A M M ( ( C C P P 1 1 0 0 0 0 0 0 C C O O N N T T R R O O L L L L E E R R ) ) SCHÉMA DE CÂBLAGE 25KW (CONTRÔLEUR CP 1000) DIAGRAMA DE C.
• Check oil every 8 hours of operation. • Change oil and oil filter every 100 hours of operation. • Change air filter every 400 hours. • Replace spark plugs every 500 hours . • Check Coolant level every 8 hours of operation. Check coolant mixture at least twice a year using a hygrometer.
SYMPTOM Engine will not crank in Manual mode. Engine will crank in manual mode but will not start. Engine runs but no A.C. output from the generator. Fault light on, engine will not start. Engine starts but shuts down immediately. Battery will not stay charged.
Coleman PowerSt ation™ St ationary S t andby 3-Y ear or 1500 Hour Limited W arranty Your Coleman PowerStation™ emergency back up power system generator has been manufactured to stringent guidelines & standards for years of dependable operation & service.
Hour Maintenance Performed Meter Time Hour Maintenance Performed Meter Time M M A A I I N N T T E E N N A A N N C C E E L L O O G G Always follow the engine manufactures recommendations when performing maintenance. Use this page to track the maintenance which is performed.
P P A A R R T T S S D D R R A A W W I I N N G G - - E E X X H H A A U U S S T T S S Y Y S S T T E E M M PLAN DES PIÈCES - SYSTÈME D'ÉCHAPPEMENT DIAGRAMA DE PIEZAS - SISTEMA DE ESCAPE P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS 1 0058015 1 Tailpipe .
P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS P P A A R R T T S S D D R R A A W W I I N N G G - - E E N N C C L L O O S S U U R R E E PLAN DES PIÈCES - BOÎTIER DIAGRAMA DE PIEZAS - CARCASA 24 1 115-0206 1 Lid assembly (includes lid and .
P P A A R R T T S S D D R R A A W W I I N N G G - - C C O O O O L L I I N N G G S S Y Y S S T T E E M M PLAN DES PIÈCES - SYSTÈME DE REFROIDISSEMENT DIAGRAMA DE PIEZAS - SISTEMA DE ENFRIAMIENTO 25 P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS 1 115-0211 1 Radiator panel .
P P A A R R T T S S D D R R A A W W I I N N G G - - D D O O O O R R A A S S S S E E M M B B L L Y Y PLAN DES PIÈCES - ENSEMBLE DE PORTE ESQUEMA DE PIEZAS - CONJUNTO DE LA PUERT A 26 P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS 1 See page 24 1 Door assembly .
P P A A R R T T S S D D R R A A W W I I N N G G - - F F U U E E L L S S Y Y S S T T E E M M PLAN DES PIÈCES - SYSTÈME D'ADMISSION DIAGRAMA DE PIEZAS - SISTEMA DE COMBUSTIBLE Item Art Art 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 *N/A NOTE: Seal all connections with gas tape.
P P A A R R T T S S D D R R A A W W I I N N G G - - G G E E N N E E R R A A T T O O R R PLAN DES PIÈCES - GÉNÉRA TRICE DIAGRAMA DE PIEZAS - GENERADOR 28 P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS 1 0059337 1 Rectifier service kit w/var, dio .
P P A A R R T T S S D D R R A A W W I I N N G G - - 2 2 5 5 K K W W B B R R E E A A K K D D O O W W N N PLAN DES PIÈCES - VUE ÉCLA TÉE 25 KW DIAGRAMA DE PIEZAS - DESGLOSE DEL MODELO DE 25 KILOV A TIOS 29 P P A A R R T T S S L L I I S S T T LISTE DES PIÈCES LIST A DE PIEZAS 1 059-0332 4 Bolt, M10-1.
P P A A R R T T S S D D R R A A W W I I N N G G - - C C O O N N T T R R O O L L P P A A N N E E L L E E N N D D A A S S S S E E M M B B L L Y Y PLAN DES PIÈCES - ENSEMBLE DE T ABLEAU DE COMMANDE DIAG.
P P A A R R T T S S D D R R A A W W I I N N G G - - C C O O N N T T R R O O L L P P A A N N E E L L B B R R E E A A K K D D O O W W N N PLAN DES PIÈCES - VUE ÉCLA TÉE DU T ABLEAU DE COMMANDE DIAGRA.
P P A A R R T T S S D D R R A A W W I I N N G G - - B B A A T T T T E E R R Y Y H H O O L L D D D D O O W W N N PLAN DES PIÈCES - FIXA TION DE LA BA TTERIE DIAGRAMA DE PIEZAS - SUJECIÓN DE LA BA TER.
デバイスColeman PM402511の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Coleman PM402511をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはColeman PM402511の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Coleman PM402511の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Coleman PM402511で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Coleman PM402511を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はColeman PM402511の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Coleman PM402511に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちColeman PM402511デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。