1 E IMI Cornelius Inc; 1994–2003 10/4/94 166239001 Revised 10/8/03 Rev . Level1 www .cornelius.com T elephone (800) 238-3600 INST ALLA TION INSTRUCTION THIS INST ALLA TION INSTRUCTION APPLIES TO ALL MODELS OF DROP-IN AND FREE-ST ANDING ICE COOLED DISPENSERS.
10/4/94 166239001 2 Revised 10/8/03 E IMI Cornelius Inc; 1994 – 2003 Rev . Level 1 5. Remove any excess sealant. Note: For non-electrical valves, skip the next step. 6. Mount the T ransformer power supply under the counter , in a position to allow access to the electrical outlet and to allow the 24V power cord to reach the dispenser .
10/4/94 166239001 3 Revised 10/8/03 E IMI Cornelius Inc; 1994 – 2003 Rev . Level 1 C. Continue to activate the dispensing valve in cycles ( “ ON ” for 15-seconds, “ OFF ” , then “ ON ” for 15-seconds). Repeat “ ON ” and “ OFF ” cycles for 15-cycles.
10/4/94 166239001 4 Revised 10/8/03 E IMI Cornelius Inc; 1994 – 2003 Rev . Level 1 4. Remove sanitizing solution source from the syrup system. 5. Allow sanitizing solution to remain in the syrup systems for not less than 10 or no more than 15-minutes (max.
10/4/94 166239001 5 Revised 10/8/03 E IMI Cornelius Inc; 1994 – 2003 Rev . Level 1 CLEANING THE ICE BIN 1. Prepare a mild detergent soap solution in 100 ) F potable water . 2. Using a nylon (not wire) bristle brush, clean the cold plate and the interior of the ice bin with the soap solu- tion.
10/4/94 166239001 6 Revised 10/8/03 E IMI Cornelius Inc; 1994 – 2003 Rev . Level 1 5. Fill the bin with 32 ) F ice. DO NOT use ice taken directly from a freezer . 6. Adjust the brix (water-to-syrup ratio) for post-mix valves. 7. Set the flow rate for pre-mix valves.
10/4/94 166239001 7 Revised 10/8/03 E IMI Cornelius Inc; 1994 – 2003 Rev . Level 1 TROUBLESHOOTING TROUBLESHOOTING T rouble Probable Cause Remedy ADJUSTMENT OF DISPENSING V AL VE SYRUP FLOW REGULA T OR DOES NOT INCREASE TO DESIRED W A TER-TO-SYRUP ‘‘ RA TIO ’’ A.
10/4/94 166239001 8 Revised 10/8/03 E IMI Cornelius Inc; 1994 – 2003 Rev . Level 1 T rouble Remedy Probable Cause DISPENSED PRODUCT COMES OUT OF DISPENSING V AL VE CLEAR BUT FOAMS IN CUP OR GLASS A. Oil film or soap scum in cup or glass. A. Use clean cup or glass.
10/4/94 166239001 9 Revised 10/8/03 E IMI Cornelius Inc; 1994 – 2003 Rev . Level 1 T rouble Probable Cause Remedy ONL Y CARBONA TED WA TER DISPENSED, Continued G. Dispensing valve syrup flow regulator , syrup tank quick disconnect, or syrup lines restricted.
デバイスCornelius Drop-In and Free-Standing Ice Cooled Dispensersの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cornelius Drop-In and Free-Standing Ice Cooled Dispensersをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCornelius Drop-In and Free-Standing Ice Cooled Dispensersの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cornelius Drop-In and Free-Standing Ice Cooled Dispensersの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cornelius Drop-In and Free-Standing Ice Cooled Dispensersで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cornelius Drop-In and Free-Standing Ice Cooled Dispensersを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCornelius Drop-In and Free-Standing Ice Cooled Dispensersの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cornelius Drop-In and Free-Standing Ice Cooled Dispensersに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCornelius Drop-In and Free-Standing Ice Cooled Dispensersデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。