Agilent TechnologiesメーカーE8285Aの使用説明書/サービス説明書
ページ先へ移動 of 464
1 Agilent Technologies E8285A CDMA Mobile Station Test Set Reference Guide Firmware Version A.05.00 and Above Agilent Part Number: E8285-90 016 Printed in U.
2 S:agilente82 85REFGUIDEMANUALfrn tmt.fb © Copy right Agil ent T echnologies 1999, 200 0 Notice Inform ation co ntained i n this doc ument is sub ject to c hange wi thout not ice.
3 Manufactu rer’ s Declaration This sta te me nt is pr ovi ded t o c omply wit h t he r eq uir emen ts of t he Germa n Soun d Emission Di rective , from 18 Jan uary 199 1. This prod uct has a s ound press ure emi ssion (at th e opera tor posi tion) < 70 dB(A).
4 S:agilente82 85REFGUIDEMANUALfrn tmt.fb Safety Considerations GENERAL This produc t and relat ed documentat ion must be rev iewed for famili arizati on with safety mark ings an d instruc tions bef ore ope ration.
5 Safety Conside rations for this Instrument WARNING This product is a Saf ety Clas s I instrumen t (provid ed with a protective earthing gr ound incorporated in the power cord). The mains plug shall only be inserted in a socket outlet pr ovided wi th a pro tective earth contact.
6 S:agilente82 85REFGUIDEMANUALfrn tmt.fb WA R N I N G : Always use the three-prong ac power cord supplied with this product. Failure to ensure adequa te earth grounding by not using this cord ma y cause product da mage.
7 Agilent Technologies Warranty Statement for Commercial Products Agilent Technol ogies E8285A CDMA Mobi le Statio n Test S et Duration of Warranty: 1 year 1. Agilent Technologies warran ts Agilent Technologies hardware, accessories and supplies against defects in materials and work manship for the period s pecified above.
8 S:agilente82 85REFGUIDEMANUALfrn tmt.fb 8 Agilent Technologies will b e liable for dam a g e to tangible property per incident up to the greater of $ 300,000 o r the actual amount paid for the produ.
9 European Conta ct: Y our local Agi lent T ec hnologies Sales and Ser vice Offi ce or Agilent T echnolog ies GmbH Depar tment ZQ/Stand ards Europe, Herr enberger Strasse 130, D-71034 B ö blinger , G.
10 S:agilente82 85REFGUIDEMANUALfrn tmt.fb Agilent Technol ogies E8285A Support Contacts The document at ion suppl i e d with yo ur t es t se t i s an excellent sourc e of ref er enc e, applica tions, and service informati on.
11 T able 1 Regional Sales and Service Offices United States of A merica: Agilent T echnologies T est and Measurement Call Center P .O. Box 4026 Englewoo d, CO 80155 -4026 (tel) 1 80 0 452 4844 Canada : Agilent T echnologies Canad a Inc.
12 S:agilente82 85REFGUIDEMANUALfrn tmt.fb In this Book Throughout this manua l the ter m "T est Set" is us ed to denote t he Agilent T echnologi es E8285A. T est Set s creens sho wn in th is manual may not match those di splayed on the T est Set in every d etail.
13 Documentat ion Map All of th e follo wing lite ratur e, with th e except ion of th e Instru ment BA SIC Use r ’ s Handbook, i s shipped wit h the Agilent T echno logies E8285A on a CD-ROM.
14 S:agilente82 85REFGUIDEMANUALfrn tmt.fb Inst rument Ba sic User’s Ha ndbook (E 2083-900 00) This gui de contain s a complete l isting o f IBASIC commands . This guide is not shipped wi th th e T est Set. For orderin g informat ion, con tact your nearest re - gional s ales offi ce.
Contents 15 Descript ion of Keys Keys .................................... ........................... ........................... ................................. ..................... .... 31 Address .............. ........... ....... ........... .
Contents 16 Guideli nes for Using Nu meric Entry Field Data Functio ns ...... ........... ........... .................. .................. ....... .......... 63 USER Keys ............... ........................... .................. ................
Contents 17 CDMA Cellular Mo bil e Receiv er Block Diagr am ...... .... .... ... .................. ................... .................. .................. .... .. 103 CDMA Cellular Mobil e T ransmitter T est Screen .. .................. ...........
Contents 18 TESTS (Ord er of T ests)........... ........... ....... ........... ........... .................. .................. ................... .......... ........ ....... ...... 137 TESTS (Pa ss/Fail Limits) .............. ........... .........
Contents 19 Audio In Lo .............. .................. .................. .................. .................. .................. ........ .................. ........... ............. 169 Audio Ou t ......... .................. ...................
Contents 20 Cnfg (Exter na l Devices) ................ ................... .................. .................. .................. ...................... ... ................... .. 205 Cntry Cod e ........ ........... .................. .............
Contents 21 Enter AS CII Data ............. ........... .................. .................. .................. ....... ........... ........... .................. ........... .......... 245 Enter Hex Data ............. ........... .................. .
Contents 22 Hard Handof f (annunc ia tor) ........... .... .... ... .... .................. .................. .................. ................... .. ............ ................. 271 GPIB Adrs ...... ........... ........... .................. ...
Contents 23 Mic Pre- Emp ............ .................. .................. .................. .................. .................. ........ .................. ........... ....... ...... 296 Min Power ...... ... .... .... ... .................. .....
Contents 24 Page Se nt (annun ciator) .......... .................. .................. ................... .................. ....... ........... ... ........ .................. ...... 328 Paging (S ector A Po wer) ......... .................. .......
Contents 25 RAND_U ............... ........... .................. ....... ........... ........... .................. .................. ................... .................. ............. 353 RANDU ............. ........ .......... ........... ......
Contents 26 Select P rocedure Location.... ....... ........... ........... ....... ........... ........... .................. .................. .... .............. ................. 382 Send Msg ........ ... .... .... .................. .............
Contents 27 System ID .......... ........ .......... ........... .................. ................... .................. ....... ........... .............. ........... ........ ........... .. 418 System T ype (Cal l Control) ............ ...........
Contents 28.
29 1 Description of Keys The keys a re list ed in alpha betical order ..
30 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Figure 1 Agilent Technologies E8285A Front Panel.
31 Chapter 1, Descripti on of K eys Keys Keys Addres s Press a nd releas e the Shif t key , then the Loca l key to display t he GPIB addr ess of the T est Set.
32 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys Assign This key i s used to assign the User Ke ys, K1 throug h K5, and K1’ th rough K3’. Press an d release the Shift key , then the K4 key to select the Assi gn functi on.
33 Chapter 1, Descripti on of K eys Keys To Turn Measurement Averaging ON and OFF. Use the :A VERag e:ST A T e comm an ds to turn th e avera ging data f uncti on ON a nd OFF .
34 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys To Query the Nu mber of Averages. Use the :A VERage:V ALue? commands to query th e number of average s used by t he averagi ng algori thm.
35 Chapter 1, Descripti on of K eys Keys End/ Release When this k ey is pres sed, the T est Set disc onnects any CDMA-mode cal l that i s current ly connected . GPIB Ex ample “DISP CCNT;CDMA:CALL:END” Enter Ente r is use d to sel ect a fi eld or scree n, and t o ente r numb ers w hen th e unit-o f- measure i s not spec ified.
36 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys Incremen t ÷ 10, Increment set, Increment x10 Thes e key s are u sed to chang e the incr e ment /de cr emen t valu e whe n cha ngin g fiel d value s. The incr ement divid e-by-10 f unction r educes the increment setting by a facto r of 10.
37 Chapter 1, Descripti on of K eys Keys NOTE: When querying a field setting or measurement result thro ugh GPIB, the Test Set always returns numeric valu es in GPIB units or attrib ute units, regardles s of the field’s current dis play units setting.
38 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys NOTE: When queryin g a field setting throu gh GPIB, the Test Set always returns nume ric values in GPIB units or attribute u nits, regardless of the field’s current display units setting.
39 Chapter 1, Descripti on of K eys Keys Programming Increment × 10 NOTE: Integer- only fields ( such as Intensity and Print Adrs ) h ave a fixed increment of 1 , and cannot be chan ged.
40 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys Loca l Local re turns the instrum ent to man ual contr ol after GPIB contro l is used, except when the T est Set is in local -lockout mode.
41 Chapter 1, Descripti on of K eys Keys To Turn High and Low Measurement Limit Checking ON and OFF. U se th e :HLI Mi t:ST A T e a n d :LL IMit:S T A T e c o mmands to tur n high a nd low measurement limit c hecking ON and OFF .
42 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys To Set the Display Units for High and Low Measurement Limits. Use the :HLIMit:DUNi ts and :LLIMi t:DUNits commands to set th e units-of -measure used to displ ay the hi gh and low meas urement limit value s .
43 Chapter 1, Descripti on of K eys Keys To Query the High and L ow M eas urement Limit Setting s. Use the :HLIMit:V ALue? and : LLIMit:V ALue? commands to q uery the high and low measu reme n t limit se tting s.
44 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys To Reset Measurement Limit Detection. Use the :HL I Mit: R ESet and :LLIMi t:RESet command s to rese t measuremen t limit de tection .
45 Chapter 1, Descripti on of K eys Keys Meter The Mete r functi on dis plays mea suremen ts graphi cally . The Meter f ormat i s avail able fo r most mea sure ments. T o determ ine if the Me ter for mat is p rovid ed for a measu rement, posit ion the cu rsor i n front of the measur ement’ s units f ield and press t he knob.
46 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys To Query the State of the Meter. Use the : MET er:ST A T e? commands t o query t he state o f the anal og bar -graph meter . The query ret urns a 1 if t he meter i s ON, and a 0 if t he meter is OFF .
47 Chapter 1, Descripti on of K eys Keys To Set th e Mete r High End and Low End P oin ts. Use the :M ET er:HEND and :MEte r :LEND command s t o set t he a nalog bar- gra ph meter ’ s high endpoin t and low en dpoint.
48 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys To Set th e Mete r High End and Low End P oin t Displa y Units. Use the : MET er:HEND:DUNits and :MEter:LEND:DUNits commands to se t the analog ba r- graph meter high end po int and lo w end point displa y units.
49 Chapter 1, Descripti on of K eys Keys No Ratio W No is us ed to disreg ar d s el ect ed operations before they a re exe cuted. Press t he No Ratio W key to answe r no to pro mpts requir ing a yes or no r eply . GPIB Ex ample No equivalent GPIB command On/Off See Yes On/Off field description, on page 56 .
50 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys Print Pressin g Print out puts the entire c ontents o f the dis played scr een, the t ime and date, and any print titl e define d in the PRI NTER CONFIGURE screen.
51 Chapter 1, Descripti on of K eys Keys Ref set Press and re lease the Shift key , then the Incre m ent ÷ 10 key to access the re fe re nce set fun cti on. This fu nctio n is us ed to ente r or r emove a mea surement refe re nce for relative AF and RF measure ments.
52 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys To Set A Measurement Reference Point. Use the :R EFere nce:V ALue c ommand s to set a mea surement re ference point.
53 Chapter 1, Descripti on of K eys Keys To Set Measurement Reference Point Display Units. Use th e :REFe rence :DUN its commands to set a mea surement r eference poi nt’ s display un its.
54 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys Register This key c auses the mobile sta t ion to perfor m a CDMA zone-ba sed regis tratio n. See "Register (CDMA)" on page 3 58 . Release This key i s used to delete the assignme nt of the User Keys , K1 through K5, and K1’ throu gh K3’.
55 Chapter 1, Descripti on of K eys Keys NOTE: The :REGister:CLEar:ALL command is only valid for the internal save/recall mass storage device. To clear all saved instrument states from the Card, RAM, or Disk save/recall mass storage devices, each file must b e removed individually u sing the :REGister:CLEar ’ <file name>’ command.
56 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Keys Yes On/Off Y es is used to co nfirm selected ope ra ti ons befo re they are executed. Pr ess the Y es On/Of f key to answer ye s to prompt s requiri ng a yes or no reply .
57 Chapter 1, Descripti on of K eys Symbol Ke ys Symbol Keys Backspace The backs pace key i s used t o move the c ursor to the left when enter ing numbers in a field, su ch as RF Gen Freq . Each pres s of this ke y moves t he cursor one place to the l eft, erasi ng the prev ious character .
58 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Symbol K eys Units-of-Measure Keys The units keys ar e for enter ing and chan ging th e unit-of -measure (s uch as GHz, V , dBm, %, mW , a nd so forth ) for me asure ments or fie ld ent ries.
59 Chapter 1, Descripti on of K eys Miscell aneous Hard ware Miscell aneous Hard ware Front Panel Knobs Cursor Control Knob The lar ge knob on the T est Set’ s front pan el has three functio ns: • Movi ng th e curso r . • Selecting fields, screens, and s ettings from a list of ch oices .
60 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys Progr amma ble Fron t-Panel Keys for S cree n s Programmable Front-Panel Keys for Scre ens Ta b l e 2 Key Name Screen Display.
61 Chapter 1, Descripti on of K eys Non-Pr ogrammable Fr ont-Panel K eys and Functi ons Non-Programmable Front -Panel Keys an d Functions ON/OFF Power Swit ch VOLUME Control Knob Cursor Contr ol Knob .
62 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys D A T A FUNCTIONS Keys DATA FUNCTIONS Keys The DA T A FUNCTIONS keys can b e divi ded int o two grou ps; th ose wh ich af f e.
63 Chapter 1, Descripti on of K eys D A T A FUNCTIONS Keys Guidelines f or Using Numeric E ntry Field Data Func tions • Increment values are set, scaled, and changed for individual numeric entry fields. The GPIB data function comm a nd s must immediat ely follow the GPIB comm and for the individual field.
64 S:agilente8285REFGUIDEMANUALkeys.chp Chap ter 1, Des cri ptio n of Keys USER Keys USER Keys User keys instant ly access instrument setti ngs without using the knob. Y ou can use user keys to move quickly be tween fie lds on the same scree n, and to acc ess field s ettings th at are not normal ly avail able on the screen yo u are usin g.
65 2 Description of Connectors The connec tors are listed i n alphabe tical or der ..
66 S:agilente82 85REFGUIDEMANUALconn ectr .chp Chapter 2, Desc ription of Conne ctors Figure 2 Agilent Technologies E8285A Front Panel Figure 3 Agilent Technologies E8285A Rear Panel DUPLEX OUT RF IN/OUT POWER ANTENNA IN VOLUME AUDIO OUT AUDIO IN High Low Max power 60 mW Max 12V peak Max 42V peak DO NOT apply RF when in standby Max power 2.
67 Chapter 2, Desc ription of Connecto rs Connector s Connectors ANTENNA IN The anten na input i s used to a nalyze lo w-power RF signals ( ≤ 200 mW), and is typical ly used f or of f-the- air measur ements.
68 S:agilente82 85REFGUIDEMANUALconn ectr .chp Chapter 2, Desc ription of Conne ctors Connector s AUDIO IN LOW, HIGH The audio inputs are used t o input a udio signa ls to the AF Analyzer . • AUDIO IN HI is the main au dio signal input conn ection. • AUDIO IN LO is used for the audio signal reference.
69 Chapter 2, Desc ription of Connecto rs Connector s AUDIO OUT The audio output is used to out put signa ls from AF Gene rators 1 and 2. Operating Considerations •B N C • Output impedance <1 .
70 S:agilente82 85REFGUIDEMANUALconn ectr .chp Chapter 2, Desc ription of Conne ctors Connector s CELL SITE/ TRIGGERS This is a DB-25 con nector . It provide s various CDMA trigge rs and d igital cel l diagnost ics. Operating Considerations • Pins 1, 2, 3 Grou nd • Pin 4 - Cl osed Loop Power Co ntrol Ramp Down (CSD1_TRIG1) TTL, 1.
71 Chapter 2, Desc ription of Connecto rs Connector s CDMA CLOCK MUX OUTPU T The CDMA frame clocks provide the CDMA timing re ferences for generating and demodulat ing CDMA signals . The CDMA clock MUX out put provid es the followi ng CDMA frame clocks o n a multiplexe d output.
72 S:agilente82 85REFGUIDEMANUALconn ectr .chp Chapter 2, Desc ription of Conne ctors Connector s DUPLEX OUT The duplex output is an out put for t he RF Generat or and T racking Gen erator . Operating Considerations •T y p e N • Output impedance = 60 Ω • The RF Generator's outpu t is s elected in the Output Port field.
73 Chapter 2, Desc ription of Connecto rs Connector s EXT RE F INPUT This input pro vides a frequenc y ref er enc e for the T est Set’ s internal phas e-locked- loops. Operating Considerations •B N C • This T e st Set does no t require a jumper between the 10 MHz OUTPUT and the EXT REF I N PU T.
74 S:agilente82 85REFGUIDEMANUALconn ectr .chp Chapter 2, Desc ription of Conne ctors Connector s MODULATION INPUT This conn ector pro vides a n externa l modulati on connect ion to the RF Generator .
75 Chapter 2, Desc ription of Connecto rs Connector s PARALLEL PORT This port is u sed w it h prin ters re quiri ng a p ar allel i nterf ace w hen pr in ting scree n images or test re sults. Set the Printer Port : field (on t he PRINT CONFIGURE screen or TESTS (Pri nter Setup) s creen) t o Parallel to print using th is port.
76 S:agilente82 85REFGUIDEMANUALconn ectr .chp Chapter 2, Desc ription of Conne ctors Connector s RF IN/OUT The RF IN/OUT por t allows full-dup lex inte raction, or the RF IN portio n can be used with the DUPLEX OUT port , which pr ovides in creased ou tput power .
77 Chapter 2, Desc ription of Connecto rs Connector s SERIAL PORT 9 This conn ector is the primar y serial port (SERI AL POR T 10 is the s econdary) , and is us ed for se rial dat a exchange with an external dev i ce.
78 S:agilente82 85REFGUIDEMANUALconn ectr .chp Chapter 2, Desc ription of Conne ctors Connector s SERIAL PORT 10 This con nec tor is a sec onda ry serial port ( SERIAL POR T 9 is the primary), a nd is used for serial data e xchange wit h an exte rnal device.
79 Chapter 2, Desc ription of Connecto rs Connector s TRAFFIC CHANNEL LOGGING (DCS1>) The T raff ic Channel Logging port provides for loggi ng protoc ol sig naling fr om the T raf fic chann el. Refe r to Prot ocol Loggin g in the Applicatio n Guide .
80 S:agilente82 85REFGUIDEMANUALconn ectr .chp Chapter 2, Desc ription of Conne ctors Connector s 10 MHz OUTPUT The 10 MHz outp ut is one output of a reference p hase-locked-l oop that ge nerates 10 MHz re ference sign als for a ll of th e digita l and analog ph ase-locke d-loops i n the T est Set.
81 3 Description of Screens These scr eens are listed i n alphabet ical or der ..
82 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Adjacent Channel P ower Screen Adjacent Chan nel Power Screen Figure 4 The Adjacent Channel Power Screen This scr een is used t o measure Adja cent Channel Power .
83 Chapter 3, Descriptio n of Screens Adjacent Channel P ower Scre en How the Test Set Measur es Adjacent Chan nel Power (ACP) When you acc ess this s creen, t he T est Set aut omaticall y starts a multi-st ep process for me asuring ACP: 1. AF Generator 1 is turned off if the Carrier Ref f ield is set to Unmod .
84 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s AF Anal yzer Screen AF Analyzer Screen Figure 5 The AF Analyzer Screen "AF Analyzer Block Diagram" on pa.
85 Chapter 3, Descriptio n of Screens AF Analyzer Screen AF Analyzer Block Diagram Figure 6 AF ANALYZER Functi onal Block Di agram 1 The Settling , Gain Cntl , and Ext L oad R fields are not shown.
86 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Call Contr ol Screens Call Control Scr eens Figure 7 The CALL CONTROL Screen NOTE: The number and ty pe of fields disp layed on the CALL CONTROL screen depends on the selected syst em ty p e.
87 Chapter 3, Descriptio n of Screens Call Contr ol Screens Call Control Sc reens - ANALOG MEAS Figure 8 The ANALOG MEAS Screen This scr een is use d to make RF an d audio measurements on the mobile sta tion connecte d to the T est Set whi le on an ac tive voi ce channel .
88 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Call Contr ol Screens Requirements for Using The ANALOG MEAS Screen The T est Set must be in t he connect ed state (that is, the Connect annu n ciato r is lit) in o rder to use t he ANALOG MEAS screen.
89 Chapter 3, Descriptio n of Screens Call Contr ol Screens Call C ontrol Screens - AUTHE NTICAT ION Figure 9 The AUTHENTICATION Screen The AUTHENTICA TI ON screen al lows you to enter paramet ers for auth ent ic ati on i nto the T est Set.
90 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Call Contr ol Screens Call C ontrol Screens - CALL B IT Figure 10 The CALL BIT Screen The CALL BIT screen is desig.
91 Chapter 3, Descriptio n of Screens Call Contr ol Screens Using the CALL BIT Screen Using the CALL BIT screen requires expert knowledge of the cal l proces sing messag ing pro tocols used i n th e syst em selec te d in the System Type field on the CALL CONTROL screen.
92 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Call Contr ol Screens Table 3 li sts t he me s sag e n ames used to acc ess ea ch of t he s i g nali n g me ssage s availa ble on the CALL BIT sc reen.
93 Chapter 3, Descriptio n of Screens Call Contr ol Screens Querying Multiple Fields With Single OUTPUT/E NT ER When multiple queries are combined into one co mmand string the T es t Set responds by sending o ne response mes- sage contai ning indiv idual respo nse message un its separated by a respon se message unit separator (;).
94 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Call Contr ol Screens Call Control Sc reens - CALL CONFIGURE Figure 11 The CALL CONFIGURE Screen NOTE: The number o f fields dis played on th e CALL CONFIGURE scr een depends o n t he selected system type.
95 Chapter 3, Descriptio n of Screens Call Contr ol Screens Call Co ntrol Sc reens - C ALL DATA Figure 12 The CALL DATA Screen This scr een displ ays the de coded rever se contr ol channel and re verse voice channel signaling message s receiv ed by the T est Set fr om the mobil e statio n.
96 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Call Contr ol Screens The message s which can be viewed ar e: • Reverse C ontrol Ch annel Messages for Paging, Origination, Orders, and Order Conf irmati on.
97 Chapter 3, Descriptio n of Screens Call Contr ol Screens Reading the CALL DATA Screen Message Fields This sec tion provi des progr amming infor mation on how t o read th e individ ual fields from the de coded reve rse contr ol channel and rever se voice channel signali ng messa ges availabl e on the CALL DATA screen.
98 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Call Contr ol Screens Querying a Single Field Example of Qu erying A Sing le Field OUTPUT 714;"CALLP:DATA ’.
99 Chapter 3, Descriptio n of Screens CDMA Authentic ation Screen CDMA Authentication Screen Figure 13 The CDMA Authentication Screen The CDMA Authe nticati on screen provides t he nece ssary fe atures f or testing a CDMA mobile sta tion’ s ability t o perform call- processi ng functi ons with authent ic ati on.
100 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s CDMA Call Control Scree n CDMA Call Control Screen Figure 14 The CDMA Call Control Screen This scr een allows you to establish a call, terminate a call, and perfor m handof fs.
101 Chapter 3, Descriptio n of Screens CDMA Cell Site Configuration Screen CDMA Cell Site Configuration Sc reen Figure 15 The CDMA Cell Site Configuration Screen This scr een provi des fiel ds for set ting up CDM A cell sit e system pa rameters and fields for sett ing up an a nalog cel l site vo ice channe l for di gital to analog handof fs.
102 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s CDMA Cellular Mo bile Receiver T est Screen CDMA Cellular Mobile Receiver Te st Screen Figure 16 The CDMA Cellula.
103 Chapter 3, Descriptio n of Screens CDMA Cellular Mobile Receiver T est Screen CDMA Cellular Mob ile Receiver Blo ck Diagram Max Power, 6 W atts Contin uous RF Power -65.0000 dBm/BW Data Buffer FER Measurements PRBS ECHO RF IN/ OUT Max Frames 1000 Confidence 95.
104 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s CDMA Cellular Mo bile T ransmitter T est Screen CDMA Cellular Mobile Transmi tter Test Screen Figure 17 The CDMA Cellular Mobile Transmi tter Test Screen This scr een reports me asurements of the mobi le’ s transmit ter .
105 Chapter 3, Descriptio n of Screens CDMA Gated P ower Screen CDMA Gated Power Screen Figure 18 The CDMA Gated Power Screen.
106 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s CDMA Generator Control Scree n CDMA Generator Control Screen Figure 19 The CDMA Generator Control Screen This scr een contr ols the T est Set’ s forward CDM A channel ou tput power and relati ve code ch annel power .
107 Chapter 3, Descriptio n of Screens CDMA Ge nera tor Control Scr een CDMA Generator Control Block Diagram Pilot Off dB Sync Off dB Paging Off Traffic Off dB OCNS 0.
108 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s CDMA Mobile Reported FER Screen CDMA Mobile Rep orted FER Screen Figure 20 The CDMA Mobile Reported FER Screen This scr een displ ays FER as re ported fr om the mobil e statio n.
109 Chapter 3, Descriptio n of Screens CDMA Mobile Reported Pilot Strength Screen CDMA Mobile Rep orted Pil ot Strength Screen Figure 21 The CDMA Mobile Reported Pilot Strength Screen This scr een di splays pilot str ength d ata as repor ted fr om the mob ile s tation.
11 0 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s CDMA Open Loop Time Respo nse Screen CDMA Open Loop Time Response Screen Figure 22 The CDMA Open Loop Time Respo.
111 Chapter 3, Descriptio n of Screens CDMA Rever se Channel Spectrum Sc reen CDMA Reverse Channel Spectrum Screen Figure 23 The CDMA Reverse Channel Spectrum Screen.
11 2 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s CDMA Short Message Servic e Screen CDMA Short Message Service Scre en Figure 24 The CDMA Short Message Service S.
11 3 Chapter 3, Descriptio n of Screens CDMA Swept P o wer Measurement Scre en CDMA Swept Power Measureme nt Screen Figure 25 The CDMA Swept Power Measurement Screen The CDMA Swept Power Measurement screen provides fields f or performin g a DSP-based p ower versus time measur ement.
11 4 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s CDMA T ransmitter Po wer Range T est Screen CDMA Transmitter Power Range Test Screen Figure 26 The CDMA Transmit.
11 5 Chapter 3, Descriptio n of Screens Configure Screen Configure Screen Figure 27 The Configure Screen The CONFIGURE scre en define s a number of general o perating funct ions, such as date and time , screen i ntensit y , and beeper volume.
11 6 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Duplex T est Screen Duplex Test Screen Figure 28 The Duplex Test Screen "Duplex Test Bl ock Diagra m" .
11 7 Chapter 3, Descriptio n of Screens Duple x T est Screen Duplex Test Block Diagram Figure 29 DUPLEX TEST Functi onal Block Diagra m.
11 8 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Help Screens Help Screen s The HELP scre en is used to acc ess tutor ial inf ormation f or a wide va riety of instru ment functions . After t his scre en is acce ssed, push t he cursor -control knob to di splay the help Index.
11 9 Chapter 3, Descriptio n of Screens I/O Configure Screen I/O Configure Sc reen Figure 30 The I/O Configure Screen The I/O CONFIGURE s creen’ s fields ar e used to specify GPIB and ser ial commu nication s settin gs.
120 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Message Scree n Message Screen The MESSAGE scr een lists any error or oper ation message s that have occur red since t he instr ument was tur ned on or t he screen was cleare d.
121 Chapter 3, Descriptio n of Screens Oscilloscope Scree ns Oscillosc ope Screens Figure 31 The Oscilloscope Screen and Menus The OSCILLOSCOPE scr een’ s controls are arrange d by menu.
122 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Oscilloscop e Screens Select ing the Osci lloscope’s Inp ut The o sc illos cope ’ s input is det ermine d by th e AF Anl In fi eld sett ing in the AF ANAL YZER, TX TEST , or DUPLEX TEST sc reens.
123 Chapter 3, Descriptio n of Screens Print Configure Screen Print Configure Screen Figure 33 The Printer Configurations Screen This scr een confi gures the T est Set to print scr een images with your p rinter .
124 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s RF Anal yzer Screen RF Analyzer Screen Figure 34 The RF Analyzer Screen "RF Analyzer Block Diagram" on .
125 Chapter 3, Descriptio n of Screens RF Analyzer Screen RF Analyzer Block Diagram Figure 35 RF ANALY ZER Functiona l Block diag ram 0,6$&&.
126 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s RF Ge nera tor S creen RF Generator Screen Figure 36 The RF Generator Screen "RF Generator Block Diagram&quo.
127 Chapter 3, Descriptio n of Screens RF Generator Screen RF Generator Block Diagram Figure 37 RF GENERATOR Functional Block Diagram.
128 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s RX T est Screen RX Test Screen Figure 38 The RX Test Screen "RX Test Block Di agram" on page 12 9.
129 Chapter 3, Descriptio n of Screens RX T est Screen RX Test Block Diagram Figure 39 The RX Test Fields and Their Functions NOTE: Since most of the measuremen ts displayed are dependent on d ifferent field settings, the settings and values shown in the diagrams use the Test Set’s preset conditions.
130 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Service Scre en Service S creen NOTE: This screen is used for comp onen t- level trou bleshoo tin g by the m anuf actu rer . This method of troubles hooting i s not curr ently supported outside of the factor y .
131 Chapter 3, Descriptio n of Screens Spectrum Anal yzer Screens Spectrum Analyze r Screens Figure 40 The Spectrum Analyzer Screen and Menus The SPECTRUM ANAL YZER scree n’ s contr ol s are arr an ged in four menus. The menus are accessed u sing the Controls field.
132 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s Spec trum Ana lyzer Scre e ns Using the Spectrum Analyzer Automatic Calibration During ope ration, t he Spectr um Analyzer p auses for approximat ely 2 seco nds every 5 mi nutes to r ecalibr ate itself .
133 Chapter 3, Descriptio n of Screens TESTS Screens TESTS Screens Figure 41 The TESTS (Main Menu) Screen Description of the Tests Sub system The TESTS scr eens are t he also r eferred to as the T ests Subsyst em; a group of screens used to cr eate, edit, and r un automat ed test progr ams.
134 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s TESTS Screens TESTS ( Main Men u) Figure 42 The TESTS (Main Menu) Screen When you pre ss the TESTS key , you access the mai n TESTS scree n. The other screens of the s ubsystem are accessed us ing the CUSTOMIZE TEST PROCEDURE: or SET UP TEST SET: list s.
135 Chapter 3, Descriptio n of Screens TESTS Screens TESTS ( Channel Infor mation) Figure 43 The TESTS (Channel Information) Screen This scr een displ ays the ch annel frequenci es to be t ested.
136 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s TESTS Screens TESTS (T est Parameters) Figure 44 The TESTS (Test Parameters) Screen T est Paramet ers are used to.
137 Chapter 3, Descriptio n of Screens TESTS Screens TESTS ( Order of Tests) Figure 45 The TESTS (Order of Tests) Screen This scr een is use d to decid ed what sequence t he test shoul d be execut ed.
138 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s TESTS Screens TESTS (Pass/Fail Limits) Figure 46 The TESTS (Pass/Fail Limits) Screen Pass/Fai l limit s are the radio ma nufacturer’ s upper and lower limi ts used by the T es ts Su bsyste m.
139 Chapter 3, Descriptio n of Screens TESTS Screens TESTS (S ave/Delete Pr ocedure) Figure 47 The TESTS (Save/Delete Procedure) Screen After se lecting a test seque nce and def ining the approp riate sp ecifica tions, parame ters, fr equencies , and syste m configura tion, you c an save al l that info rmation as a procedure fil e for la ter use.
140 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s TESTS Screens TESTS (Executions Con ditions) Figure 48 The TESTS (Execution Conditions) Screen The TESTS (Exe cution Conditions ) screen determine s how tests are run.
141 Chapter 3, Descriptio n of Screens TESTS Screens TESTS ( External Devi ces) Figure 49 The TESTS (External Devices) Screen The T ests Sub system c an only ac cess exte rnal devi ces if t hey have bee n configur ed. Most external devices u se the GPIB po rt for control .
142 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s TESTS Screens TEST S (Pri nter Set up) Figure 50 The TESTS (Printer Setup) Screen The TESTS (Pr inter Set up) scree n determin es how test s are run .
143 Chapter 3, Descriptio n of Screens TESTS Screens TEST S (IBAS IC Cont roller ) Figure 51 The TESTS (IBASIC Controller) Screen The IBASIC con troller i s used to run I BASIC programs . This screen i s also used as a s ta nd- al one IBASI C c omput er .
144 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s TX TEST Screen TX TEST Screen Figure 52 The TX Test Screen "TX Test Bl ock Dia gram" on page 145.
145 Chapter 3, Descriptio n of Screens TX TEST Screen TX Test Block Diagram Figu r e 53 TX T EST F unc tion a l Bloc k Diag r am.
146 S:agilente82 85REFGUIDEMANUALscre ens.chp Chap ter 3, Des cri ptio n of S c reen s TX TEST Screen.
147 4 Description of Fields Field de scripti ons are l isted in alphabeti cal orde r ..
148 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Fields Abort Print Selec t t his field to inte rrupt the pr int i n pr ogres s.
149 Chapter 4, Des cription of Field s Fields Acc Prb Pwr This measu rement automatica lly sense s when the mob ile stat ion acces s probe power lev el crosses a t hreshold ( approximat ely -55 dBm/BW) during re gistrat ion or call attempts .
150 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Operating Considerations A sequence of access probes is tran smitted as part of t he mobile s tation’ s attempt to gain access to a CDMA system.
151 Chapter 4, Des cription of Field s Fields Access Pr obe (annunc iator) This annu nciator l ights when the mobile station trans mits an acc ess probe . This annuncia tor will rema in lit u ntil the call has been t erminated. A sequence of access probes is tran smitted as part of t he mobile s tation’ s attempt to gain access to a CDMA system.
152 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Screens Where Field is Present AF ANAL YZER DUPLEX RF ANAL YZER RX TEST Active This field is use d to tu rn o.
153 Chapter 4, Des cription of Field s Fields Active (annunciator) When li t, the Active an nunciator indicates the control chan nel of the T est Set is turned o n. If thi s annuncia tor is l it, the ba se stati on is tr ansmittin g system par ameter overhead messages on the as signed control c hannel.
154 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Add Intcp t This fi eld is use d to enter the parameter ADD_I NTERCEP T . Refer to ANSI TIA/ EIA-95-B f or additi onal det ails. This fi eld is di splayed on ly when TIA/EI A-95B is selecte d in the "Protocol" field on pa ge 346 .
155 Chapter 4, Des cription of Field s Fields AF Anl In The audio frequency analyzer input selects the input for the a nalyzer . When select ed, this f ield dis plays a l ist of ch oices. Signals can be anal yzed from t hree dif ferent ty pes of inp uts: • The output of the AM, FM, or SSB demodulators.
156 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields AF Freq This fi eld is a o ne-of-many field used to se lect the type o f measurement to be made by the Audio Frequency Anal yzer on th e audio si gnal being m easure d.
157 Chapter 4, Des cription of Field s Fields AF Freq The AF Freq fie ld is dis played onl y when the Display fiel d i s se t to Meas . This fi eld displ ays the au dio frequency of the demodula ted FM signal being transmi tted by th e mobile st ation.
158 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields AFGen1 To This fi eld has two fiel ds: • the upp er field set s the desti nation port for Audio F requency .
159 Chapter 4, Des cription of Field s Fields AFGen2 To This fi eld has two fiel ds: • the upp er field set s the desti nation port for Audio F requency Generat or 2 • FM -RF Genera tor FM mo dula.
160 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields A_Key Manua lly , this field is used to en te r the mo bile s tatio n’ s A_ k ey in to the T est Set.
161 Chapter 4, Des cription of Field s Fields Exampl e OUTPUT 714;"CALLP:AMPS:AUTH:AKEY:GEN" OUTPUT 714;"CALLP:AMPS:AUTH:AKEY?" ENTER 714;Akey_val$ Screens Where Field is Present AUTHENTICA TION A-Key Digits This field i s used to ente r the de cimal digits used to gen e rate th e A_Ke y .
162 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Alert This fiel d s ets th e Aler t pa ra mete r i n SM S mes sa ge s. •O n •O f f GPIB Exampl e "CDMA:SMS:TERM:ALERT ‘On’" sets t he Alert parame ter to “On”.
163 Chapter 4, Des cription of Field s Fields Alt Pwr Ms Cal Bands The frequen cy band occupied by the RF channel st andard enter ed in this fiel d will be in cluded in the frequ ency coverage of the cha nnel power c alibration ro utine.
164 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields AM Depth This fi eld displ ays the pe rcent dep th of modula tion of the AM sign al. The fi eld is only vis i ble when the A F ANL In field is s et to AM MOD or AM DEMOD .
165 Chapter 4, Des cription of Field s Fields Amplit ude This fi eld sets the output power of the T est Sets’ s transmitter (that i s, the out put powe r of th e T e st Se t ’ s RF Gene rator) . See “RF Ge ne ra tor” in the G PIB Command Syntax chapter of the E8285A Conden sed Pr ogramming Refe r ence Guide for progr amming command synt ax.
166 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Amplit ude (CDMA Swep t Power Measur ement) This fi eld sets the m easurem ent trig ger ampl itude. GPIB Exampl e “CDMA:SWEPtpower:TRIGger:AMPLitude ‘-1 8 dB’” sets t he trigger amplitude .
167 Chapter 4, Des cription of Field s Fields Antenna In This fi eld is use d to indi cate loss es or gai ns between t he ANTENNA IN por t and the d evice-und er- test. Ente r a positi ve value to i ndicate a gain (such as a n amplifie r). The Spectrum Analyzer’ s marker leve l ( Lvl ) me asurement i s automati cally r educed by t hat amount.
168 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields See Also “Measur ement T riggering Pr ocess” in the Operating Over view chapt er of the E8285A User’ s .
169 Chapter 4, Des cription of Field s Fields Atten Hold Attenuat or hold pr events th e fixed RF o utput att enuators from switc hing in and out, el imin at ing the loss of t he output signal as the level is changed. This fu nct ion is help ful when maki ng squelch measure ments.
170 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Audio Out Audio outp ut coupling sele cts ac or dc coupli ng of the AF Ge nerator t o the AUDIO OUT connect or . Operating Considerations This fi eld should be s et to DC for best results when using the AUDIO OUT connecto r and low data rat es.
171 Chapter 4, Des cription of Field s Fields Authen Data Clear Selecti ng Clear re moves any dat a present in th e Authenticat ion Data T able. GPIB Ex ample CDMA:AUTH:DATA:CLE?” clears the Authent ication Data Table.
172 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Operating Considerations If the Authen fiel d is Off , all Parameters d i splayed will be dashes (-), exc ept for AUTH_MODE, which will be “0”.
173 Chapter 4, Des cription of Field s Fields 10 Expected RANDC Decimal 1 1 Received RANDC Decimal 12 RA NDC Sta tus 0=Pass ed 1=Failed 13 Expected COUNT Decimal If “Unknown”, the value 255 is ret.
174 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Programming Example for Authentication Data Table 10 RE-SAVE "c:E8285Aauth.
175 Chapter 4, Des cription of Field s Fields 370 END SELECT 380 !Evaluate the third data position, Registration Type 390 Reg_type$=Data$[Comma2+1,Comma3- 1] 400 SELECT Reg_type$ 410 CASE "0".
176 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Authent This fi eld is use d to acti vate the authenti cation pr ocess with in the T est Set.
177 Chapter 4, Des cription of Field s Fields Autostart Test Procedure on Pow er-Up When set to On , thi s field a utomati cally l oads and runs t he specif ied proce dure whenever t he T est Set is turne d on.
178 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Averages This fi eld sets the number of power c ontrol gr oups (gat ed-on power periods) that will pr ovi de CDMA ga ted power measuremen t.
179 Chapter 4, Des cription of Field s Fields The foll owing list describ es the purpose f or each Agil ent T echnologies E8 285A power me asurement. For more detail, r efer to t he fiel d descrip tion for the power measurement you choose .
180 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields A verage Powe r measurements are made using a factory- calibr ated power detect or .The dete ctor measur es power du ring the t ime that power control gro ups are gat ed on.
181 Chapter 4, Des cription of Field s Fields AWGN This fie ld contro ls the Addi tive White Gauss ian Noise ( A WGN) generat or ’ s le vel. GPIB Ex amples “CDMA:AWGN:BWPower -75dBm” “CDMA:AWGN:STATe ON“ sets t he AWGN generator ’ s level to − 75 dBm.
182 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Band Cl ass The Band Cla ss field is displaye d on the CDMA CALL CONTROL scre en when the "Protocol" field on page 346 is set to TIA/EIA-95B and t he "RF Chan Std" field on page 365 is set to USER-DEF .
183 Chapter 4, Des cription of Field s Fields Screens Where Field is Present CDMA CALL CONTROL Base Freq (Use r Defined) The Base Fr equency field se ts the RF Genera tor ref erence fo r channel 0 (z ero) when the RF Chan Std field is set to USER-DEF , and the RF Display fiel d is set to Chan .
184 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Base ID This fiel d a llo w s entr y of t h e base stat ion id entif ica tio n (BA SE_I D). GPIB Exampl e “DISP CCON;CDMA:CELL:CONFigure:BID 0“ sets th e bas e iden t ificat ion o f the si mulate d CD M A cell s ite to 0 .
185 Chapter 4, Des cription of Field s Fields BER Thr esh The :BSE Tting command i s used to c ontrol t his fiel d. The query form of the command (t hat is, :BSETting? ) can be us ed to dete rmine the cu rrent c ontrol ch annel setting.
186 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Burst Time This fi eld displ ays the t ime period between the -3 dB poi nts of t he trace repres enting th e average p ower during an ense mble of CDMA RF bu rsts.
187 Chapter 4, Des cription of Field s Fields BW= This fi eld displ ays the r esolutio n bandwidth o f the CDMA spectru m analyzer . Operating Considerations This fi eld is couple d to the Span fiel d’s settin g .
188 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields by # frames When thi s field is On , the mo bile s tation will r epor t F ER at le ast as ofte n as the mobile stat ion’ s fra me counter cycles through the number of frames ent ered in the MS FER Report Interval field.
189 Chapter 4, Des cription of Field s Fields Calling Name The Calling Name fie ld i s used to e nte r th e ins tr ument’ s functi on (in up per -ca se letters) .
190 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Call Status The label s under Call Status are highl ighted by a nnunciato rs. When l it, thes e annuncia tors indi cate tha t an event took plac e or that a conditi on exist s.
191 Chapter 4, Des cription of Field s Fields Carrier This fi eld is di splayed when Carrier is selec ted from t he list o f choices available when the un named fiel d displayi ng one of t he follo wi.
192 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields CC Order The CC Order field is only vi sible whe n authenti cation i s set to ON on the AUTHENTICA TION sc reen and t he T est Set is i n the Active s tate.
193 Chapter 4, Des cription of Field s Fields Center Freq ( CDMA) This fiel d se ts the ce nt er f req uency of the CDMA spectru m an aly zer . This field is display e d when the Controls field i s set t o Main and the RF Display field on the CONFIGURE screen is set to Freq .
194 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Chan: - Chan: is divi ded into two field s: • The left -hand field displays t he voice channel n umber assign ment being used by the Test Set and the mobile station.
195 Chapter 4, Des cription of Field s Fields Channel (CDMA to Analog or Interband Handoffs) This fie ld allows e ntry of an anal og voice chan nel for CDMA- to-an alog han dof fs, or a CDMA traf fic channel for CDMA-to-CDMA hard han doff s. GPIB Ex ample “CDMA:CALL:AHAN:CHAN 1” sets th e Ch an nel fi eld to 1.
196 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Channe l BW Use th e channel bandwidt h field t o spec ify the ba ndwidth of the carrier an d adja cent chann els t o be measu red.
197 Chapter 4, Des cription of Field s Fields Chan Power This fi eld allows you to choose the CDMA Channel Power , A verage Power , or Acce ss Pro be Po wer m easur emen ts. The CDMA Channe l Power Measur ement can b e made on a signal c onnected t o the T est Set’ s RF IN/OUT or ANTENNA IN connector .
198 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Operating Considerations for the Channel Power Measurement The cross -calibr ation pr ocess is p erformed by selecti ng the Power Meas, Calibrate field .
199 Chapter 4, Des cription of Field s Fields Chan Std This fi eld is di splayed when TIA/EIA-95B i s select ed in the Pr otocol fiel d and the System T ype field, and is use d during CDMA-to -CDMA (inte r band) handof fs. The select ion made in this field will s pecify t he inter band handof f ’ s destina tion cel l band and c hannel st andard.
200 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Check Digits This fiel d displays t he six A_Key check digits . Check digits ar e calculat ed when a valid ESN i s entere d in the MS Database fiel d (usually t hrough Registrat ion).
201 Chapter 4, Des cription of Field s Fields Ch Loc: The Ch Loc: fie ld (NAMPS and NT ACS system typ es only) s ets the anal og channel location that will be assig ned to the mobile s t ation by the T est Set as either an initi al voice channel l ocation or as a hando ff c hannel lo cation assignmen t.
202 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Example OUTPUT 714;"CALLP:NTACS:CEXT:ACT?" OUTPUT 714;"CALLP:NTACS:CEXT:SETT ‘NAR ROW’&quo.
203 Chapter 4, Des cription of Field s Fields Closed Loop Pwr Cntl This fi eld sets the power control mode. • Open Loop mode causes the Test Set to send an alternating sequence of u p/down power -contr o l bits to th e mobile st ation d ur ing per iods w he n no ot her pow e r-con trol operation is being p erformed.
204 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Screens Where Field is Present CDMA TRANSMITTER POWER RANGE TEST Clr Scr This fi eld is use d to clea r the IBASIC c ontroll er scree n.
205 Chapter 4, Des cription of Field s Fields Cntl Chan The Cntl Channel fie ld is an i mmediate ac tion field. That is , whenever the :CCH annel comman d is se nt, th e chan ge is re flect ed im me d.
206 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Cntry Code This fi eld sets the base station’ s country code. Thi s field is dis played when t he fiel d "Protocol" on page 346 has IS-95A, TSB-74, or J-STD-008 selec ted and the Esc Mode field is set to Of f .
207 Chapter 4, Des cription of Field s Fields Confidence This fi eld sets the confidence c oeff icient for FER test ing. GPIB Ex ample “DISP CRXT;MEASure:CDManalyzer:FERasure:CONFidence:INTe rval 95” set s a confi denc e co ef fici ent of 95%.
208 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Range of va lues: fl oating po int number 80 thro ugh 100 See Also FER Report (Clear) fiel d des cript ion, o.
209 Chapter 4, Des cription of Field s Fields Connect (an nunciator) When li t, the Connect an nunciator indicat es that t he mobil e station i s connect ed to the T est Set on a voice ch annel.
210 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Conne cted (ann unciator ) This annu nciator i ndicate s that th e T est Set an d a mobile st ation ha ve com.
21 1 Chapter 4, Des cription of Field s Fields Cont/Single This fi eld specifies whether the oscil loscope is cont inuous ly trigg ered ( Cont ), or if it is only trigger ed eac h time Reset is sel ected ( Single ).
212 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Controls (CDMA Sw ept Power Me asurement) This fie ld allows the user t o select which of the CDMA swept power measurement menus will be displ ayed.
213 Chapter 4, Des cription of Field s Fields Controls (Oscill oscope) This fie ld all ows t he u ser to select which of th e os cil l osco pe’ s menus is displ aye d.
214 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Screens Where Field is Present AF ANAL YZER ANALOG MEAS DUPLEX TEST RX TEST TX TEST RF GENERA T OR RF ANAL YZER Data Length This fi eld speci fies the number of bits use d for eac h word of seria l data when usin g the rear -panel se rial por t.
215 Chapter 4, Des cription of Field s Fields See Also Encoding field d escriptio n, on p age 244 User Data (ASCII or Hex) field description, o n pa ge 443 Screen(s) Where Field is Present CDMA SHOR T.
216 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Screens Where Field is Present CDMA CALL CONTROL CDMA TRANSMITTER RANGE TEST CDMA CELLULAR MOBILE RECEIVER TEST CDMA CELLULAR MOBILE TRANSMITTER TEST Data Spec This fi eld is use d to deter mine how t he conten ts of the signali ng messages a re built.
217 Chapter 4, Des cription of Field s Fields Syntax :DSPecifier <’><STD/BITS><’> :DSPecifier? Exampl e OUTPUT 714;"CALLP:DSP?" OUTPUT 714;"CALLP:DSP ’STD’" ENTER 714;Build_method$ Screens Where Field is Present CALL BIT Data Type This fi eld selects th e data type.
218 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Date This fi eld specifies th e current da te fo r t he internal c lock. The date can be read by a contr oller usi ng GPIB an d printed on test r esults. The format is MMDDYY (Month Day Y ear) , using two d igits fo r each term.
219 Chapter 4, Des cription of Field s Fields DC Level When set to DC Level , t his fi eld disp lays the D C vo ltage ente ring at t he D C inpu t port on t he back of the T est Set. This fi eld is a o ne-of-many field used to se lect the type o f measurement to be made by the Audio Frequency Anal yzer on th e audio si gnal being m easure d.
220 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields De-E mp Gain De-emphasi s gain di splays and selects the desired AF ana lyzer de- emphasis ampl ifier g ain.
221 Chapter 4, Des cription of Field s Fields Delet Ins This fiel d a llo w s you t o dele te an i nst ru men t fr om th e list at th e bott om of the scr ee n. Use the kn ob, up-arrow , or down-ar row key to s elect th e step wher e you want t o delet e a n ins tru ment.
222 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Detector This fi eld is used to select the type o f detector used to measure the ampl itude of the audi o signal b eing anal yzed by the Audio Freque ncy Anal yzer .
223 Chapter 4, Des cription of Field s Fields Disarm This fi eld stops a measurement in progr ess. It i s only dis played when t he Meas Cntl field is set to Single . This fie ld is n ot updat ed to s how the Mea s Cntl mod e when the T es t Set is o perated r emotely .
224 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Syntax :MODE <’><DATA/MEAS><’> :MODE? :NDMMode <’><NDATA/NMEAS><’>.
225 Chapter 4, Des cription of Field s Fields Figure 55 The CALL CONTROL Screen The message s are di splayed i n six non-la beled rec eived dat a fields ( that is, there is no fiel d label on the displ ay screen ). The fie lds are na med RCDD1 through RCDD6.
226 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields The co ntrol pro gram quer ies thes e rece ived data fields to obtain the displaye d info rmation st rings.
227 Chapter 4, Des cription of Field s Fields T able 9 Information Strings A vailable From Reverse Control Channel Reverse Control Channel Message I nformation Strings Displayed Di splayed in Received.
228 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Reading The Received D ata Fields T o read t he deco ded data mes sages rec eived from the mobil e stat ion o.
229 Chapter 4, Des cription of Field s Fields Figure 57 CALL CONTROL Screen with Meas Selected For syst em type NAMPS t he followi ng paramete rs are mea sured when t he T est Set is i n the conne ct stat e.
230 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Figure 58 CALL CONTROL Screen with NMeas Selected Reading The Modulation Quality Measurement Fields The MEAS .
231 Chapter 4, Des cription of Field s Fields Display Interim Results This fi eld allows the displ ay of the current FER, errors, and number of frames counted wh ile a me asurement i s in prog ress. • Yes displays perio dic updates from the cell site’s processor.
232 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Display Word This fi eld is used to select the desir ed rev erse cont rol channe l or reverse vo ice channel m essage t o be displ ayed. The :DA T A comman d is used t o control this fi eld.
233 Chapter 4, Des cription of Field s Fields Display Word Choices AuthWORD Standard Equivalent : Word C - Authenti cation Word Message Fields: AUTHR, COUNT, F, NAWC, Parity, RANDC BSChalO rd Standar .
234 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields RECCW E Standard Eq uivalent: W ord E - Seco nd Word of the Called-Add ress Message Field s: F, Dig 9 thr oug.
235 Chapter 4, Des cription of Field s Fields E This fie ld displ ays the ext ended addr ess word re ceived fr om the mobil e. • Set to ‘1’ if the exten ded address word is sen t. • Set to ‘0’ if the exten ded address word is not sent. F This fi eld disp lays the f irst wor d indicatio n received from t he mobile st ation.
236 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields SCM This fi eld display s the mobile stat ion’ s received st ation cl ass mark. Serial This fi eld displ ays the s erial numbe r of the mob ile stat ion. T This fie ld displ ays the mess age type r eceived f rom the mo bile stati on.
237 Chapter 4, Des cription of Field s Fields Drop Intcpt This fi eld is u sed to enter the paramet er DROP_INTE RCEP T . Refer to ANSI TIA/ EIA-95-B f or additi onal det ails. This fi eld is di splayed on ly when TIA/EI A-95B is selecte d in the "Protocol" field on pa ge 346 .
238 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Drop Timer This fi eld turns the call drop t imer on or o ff. • On – the call drop timer is activated. I f, during a call, the Test Set does not receive a signal f rom th e MSUT for a per iod of 2 56 frames, the call is dropped.
239 Chapter 4, Des cription of Field s Fields DSAT On the analo g CALL CONTROL screen, the DSAT: f ield i s displaye d only when the System Type field is s et to NAMP S or NTACS . The DSAT: fi eld is l ocated in the Voice Channel Assignment field, and it is divided i nto subfi elds.
240 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields NOTE: Use the CALL CONTROL screen to set the DSAT sequence. Using the SIGNALING ENCODER screen to change the DSAT will cau se d rop ped calls. The DSA T e ntered in this field is used in di gital t o analo g handof fs.
241 Chapter 4, Des cription of Field s Fields DSAT Meas This fi eld is di splayed onl y when the System Type fiel d is set t o NAMPS or NTACS . This fi eld is use d to sele ct what the signa ling deco der will d ecode.
242 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Duplex Out This fi eld is use d to indi cate loss es or gai ns between t he DUPLEX OUT port and the d evice-und er- test. • Ent er a po sitive value to indicate a gain (such as an amplifier gain).
243 Chapter 4, Des cription of Field s Fields Eb/N t This fi eld is di splayed when A WGN is “On” and the Data Type field on the CDMA CALL CONTROL screen or the CDMA CELLULAR MOBILE RECEIVER TEST scre en to PRBS,1 kHz Tone , 400 Hz, or Chirp. GPIB Ex ample “DISP CGEN;CDMA:STN?“ queries the E b /N t field.
244 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Encod ing This field deter mine s how th e char acte rs in th e Use r Data field w ill be encod ed in the SMS mes sage. The ch oices cur rently a vailable are: • Octet causes each char acter to be encoded as a b yte (8-bits).
245 Chapter 4, Des cription of Field s Fields The encodi ng to be us ed by mobile stations for t he Octet e ncoding typ e is unspecif ied in t he IS-637 a nd TSB79 standa rds. While some mobil e stations u se ASCII encod ing, other s may use a di ff erent enc oding or may n ot implement the Octet en coding type at all.
246 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields 61626364656666768696A6B6C6D6E6F70 7172737475767778797A233536373839 Screens Where Field is Present CDMA SHOR T MESSAGE SER VICE Enter Proc edure Fi lename This fiel d i s us ed to ent er th e name o f the fi le y ou want to sav e or de let e.
247 Chapter 4, Des cription of Field s Fields Operating Considerations The repor t inter val is spe cified in t e rms of error co unt or fr ame count. See Also by # errors field des criptio n, on p ag.
248 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Esc Mo de This fi eld is di splayed when the fiel d called "Proto col" on page 346 has IS -95A, TSB-74, or J -STD-008 selec ted.
249 Chapter 4, Des cription of Field s Fields ESN (hex) : This fi eld displ ays the el ectroni c serial number (ESN), in hexadecimal fo rm, receiv ed from the mobile sta tion on th e reverse control channel in respon se to a forward control channel mes sage.
250 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Exec ute (H andoff) This fi eld executes a CDMA-to-anal og or CDMA-to-CDMA inter band handof f. GPIB Ex ample “DISP CCNT;CDMA:CALL:AHAN[:EXEC]” execute s the handoff .
251 Chapter 4, Des cription of Field s Fields Execute (Closed Loop Power Control Change) This fi eld allows executio n of n-up, n- down, or ramp power -control st eps.
252 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Expe cted P N Offs et The value s display ed in this column are the curr ent Sector A and Sector B pilot PN Of fsets .
253 Chapter 4, Des cription of Field s Fields Expe cted Str ength The value s display ed in this column are the expect ed pilot strengt h numbers th e mobile sta tion should be se nding to the T est Set, based on the cur rent rati o of pilot ener gy to RF power .
254 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Expec ted T_ Add This fi eld is di splayed on ly when TIA/EI A-95B is selecte d in the "Protocol" field on pa ge 346 . Refer to ANSI/ TIA/E IA-95-B , 6.
255 Chapter 4, Des cription of Field s Fields Screens Where Field is Present CDMA MOBILE REPOR TED PILOT STRENGTH Expected T_Drop This fi eld is di splayed onl y when TIS/EI A-95B is se lected i n the "Protocol" field on pa ge 346 . Refer to ANSI/ TIA/E IA-95-B , 6.
256 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields External Disk Specificatio n This fi eld is use d when stor ing and loading pr ocedures o n an exter nal disk.
257 Chapter 4, Des cription of Field s Fields Ext NG HB This fiel d allo ws the use r to s elect whet her to en able t he cu stom neig hbor list, the Sc Priority fiel d, and the NGHB Fq (Ch) field . GPIB Ex ample “CDMA:CELL:CONF:EXNB ‘On’” enables or disable s the custom neig hbor list and associ ated fields.
258 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields GPIB Exampl e “STATus:CDMA2:EVENt?” queries the CDMA_2 status event regist er. If bit 5 is set, the last g ated power test passed. I f bit 4 i s set, the last gat ed power test fai led.
259 Chapter 4, Des cription of Field s Fields FER Report (Clear) This fiel d allows the user t o clear the Err ors Repor ted and Fr ames Report ed fiel ds on the CDMA MOBILE REPOR TED FER screen. GPIB Ex ample “DISP CFER;CDMA:MOBile:FER:REPort:CLEar” clears the Errors Reported and Frame s Reported fields.
260 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields FF at Start This fi eld can onl y be contr olled pro grammatically .
261 Chapter 4, Des cription of Field s Fields Firmware This fi eld displ ays the cu rrent firmware revi sion for your T est Set. The re vision num be r is au tomati cally chan ge d wh en upda ted fi rmwar e is insta lled.
262 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields FM Deviation This is the defa ult measur ement for this fi eld. The FM Devi ation f ield displ ays the frequen cy deviati on between the FM signal and t he carrie r .
263 Chapter 4, Des cription of Field s Fields In addit ion, the p ost detec tion bandwi dth is se t at <20 Hz and >99 kH z in the Active, Re gister and Pa ge states, an d 300 Hz to 15 kHz when in th e Connected state. Thi s is done to ens ure that no signal ing ton es ar e filt ered of f .
264 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Frames This fi eld indicates t he number of fr ames cou nted duri ng the r eportin g inte rval. GPIB Exampl e “DISP CFER;CDMA:MOBile:FERasure:ERRors?“ queries the number of frames count ed by the mobile st ation duri ng an FER repor t inter val.
265 Chapter 4, Des cription of Field s Fields Freq (Chann el Info rmation ) Selecti ng this f ield dis plays the TESTS (Channel Inform ation) sc reen. Screens Where Field is Present TESTS (Main Menu) .
266 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Freq Error ( Analog) This fiel d displays fr equency erro r when Freq Error is selected fr om the follo wing .
267 Chapter 4, Des cription of Field s Fields Frequenc y (Analog) This fi eld displ ays trans mitte r frequen cy when a sig nal is pr esent and Frequency is sel ected fro m the foll owing list of choi.
268 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Gate Time This fi eld speci fies how l ong the deco der analy zes a sign al after it has be en trigge red. The lon ger the gate ti me, the grea ter the n umber of bits anal yzed.
269 Chapter 4, Des cription of Field s Fields NOTE: Decoder and Oscilloscope Interference: Th e AF autor a nging fu nction ( Auto ) takes a small amoun t of time to determine the attenuation settings for the AF Analyzer .
270 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Grid (CDMA S wept Power M easurement) This fi eld allows the us er to superim pose a gri d over t he displa y on the screen. GPIB Exampl e “CDMA:SWEPtpower:GRID ‘On’” sets t he grid to on or off.
271 Chapter 4, Des cription of Field s Fields Handoff This fi eld is di splays th e choic e of signali ng even ts that wi ll occur when the Execute field is se lect ed.
272 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields GPIB Adrs This fi eld is use d to displ ay and chan ge the GPIB addre ss of the T est Set. Operating Considerations The addre ss can be set fr om 0 to 30 by us ing the DA T A keys, or by pushing a nd then tur ning the c ursor -control knob .
273 Chapter 4, Des cription of Field s Fields Ideal Mobile Power This fi eld displ ays the powe r level t hat a mobil e stati on on a cal l should be trans mitti ng t o the T est S et.
274 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields IF Filter This fi eld selects th e desired IF fi lter bandwidth f or mod ulated si gnals being analy zed .
275 Chapter 4, Des cription of Field s Fields Input Att Input Att sets th e amount of i nput atte nuation f or the RF IN/O UT and ANTENNA IN co nnectors. The Input Att fi eld dis plays t he presen t atte nuation value, and it is used to s et the desired attenuatio n level.
276 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Input Atte n Input Att enuation sets the amount of input at tenuati on for the RF IN/OUT and ANTENNA IN connect ors.
277 Chapter 4, Des cription of Field s Fields Range of Values for Hold in CDMA SWEPT POWER MEASUREMENT Screen •0 d B •5 d B • 10 dB • 15 dB • 20 dB • 25 dB • 30 dB • 35 dB Screens Wher.
278 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Input Port This fiel d select s the RF IN or ANTENNA IN port for making RF measuremen ts. Operating Considerations Maximum power l evels for each port are pri nted on the T est Set’ s front pan el.
279 Chapter 4, Des cription of Field s Fields Insert Ch This fi eld allows you to enter a ne w channel i n frequenc y table at t he bottom of the scr een. Operating Considerations Y ou are r equired t o specify if the t est channe l is a prime tes t channel.
280 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Insrt Stp This fi eld allows you to enter a st ep in the test li st at th e bottom of the sc reen. Operating Considerations When i nsert ing a n e w test , you m ust se lect t he Step# where you want to insert a new test .
281 Chapter 4, Des cription of Field s Fields Internal This fi eld selects th e trigger sourc e. • Internal uses th e signal bei ng displ ayed for t riggering. • External uses the rear-p anel EXT SCOPE TRIGGER INPUT for triggering. This is a TTL level trigger (approximately 2.
282 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields NOTE: If no values are disp layed in the CDMA Mobile Reportin g table, the query ex ample shown above will return on ly the line feed character.
283 Chapter 4, Des cription of Field s Fields Level (div) This cont rol is d ivided int o two fie lds: The upper fiel d ( 0.00 ) se ts the int ernal trigg er lev el as a f unc ti on of vert ical divisi ons. The tr igg er leve l is indicated by smal l pointers that ap pea r on each side of the s creen (onl y used for interna l triggering).
284 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Lower Li mit This fi eld is used to set the lower lim it to be compare d with the measured re sults. If the meas ur ed res ult is below t his limi t, the test w i ll fai l.
285 Chapter 4, Des cription of Field s Fields Lvl (Open Loop Ti me Response) This fi eld displ ays the l evel at t he open loop time response meas urement mark er, relati ve to the measurement ’ s 0 dB point ( referenc ed to the mob ile stati on’ s output level b efore the test set’ s output power wa s stepped up or down .
286 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Marker: Fr eq Marker fr equency di splays th e frequen cy at the ma rker ’ s present posi tion. GPIB Exampl e “DISP CSP;MEAS:CSP:MARK:FREQ?“ queries the frequenc y at the mar ker’s pre sent positi on.
287 Chapter 4, Des cription of Field s Fields Marker: L vl This measu rement field dis plays the signal l evel of t he curren t marker po sition. GPIB Ex ample “DISP CSP;MEAS:CSP:MARK:LEV?“ queries the amplit ude at th e marker’s present positi on.
288 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Marker: Nor m/Delta This measur ement fiel d selects whethe r an additi onal marker i s displayed to allow delta v alues to b e returned.
289 Chapter 4, Des cription of Field s Fields Marker Pos (CDM A Reverse Channe l Spect rum) This fiel d is di spla yed w hen t he Controls field is se t to Marker . Th is fi eld se ts the ma rker ’ s position , referen ced to the le ft side of the dis play .
290 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Marker Time (Open Loop Time Response) This fi eld is di splayed when the Controls field on the OPEN LOOP TIME RESPONSE screen is set to Display .
291 Chapter 4, Des cription of Field s Fields Marker To: Peak+ causes the mark er to mov e to the max imum value of the ave rage level measured o n the disp lay . Peak − causes th e marker to move to t he minimum v alue of t he a verage lev el measured o n the disp lay .
292 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Mask Type This fi eld is use d to sele ct the power vers us time mask used durin g gated power measurement s to det ermine pass /fail r esults. • Original selects the mask specified by test standa rds IS-98A and TIA/EIA-98B.
293 Chapter 4, Des cription of Field s Fields Max Power The value shown unde r the Max Power label i n the upper left po rtion of the display is the maximum power mea surement r esult obt ained the last ti me a Min/ Max Po wer m easu rem en t was exe cu ted.
294 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Max Req Seq, Max Rsp Seq This fi eld allows simultane ous entry of the maxi mum number of access pr obe seque.
295 Chapter 4, Des cription of Field s Fields Meas Cntl This fi eld allows the sele ction of eithe r single or contin uous meas urements. • Single causes a measurement to be m ade each time the Arm field is selected. • Cont causes measurements to re-arm automatically until Single is selected or the call is terminated.
296 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Mic Pre-Emp Microphone pre-emp hasis det ermines whe ther the modulating s ignal fr om the MIC/ACC connect or goes throug h or bypa sse s the 7 50 ms pre- emphasi s networ k.
297 Chapter 4, Des cription of Field s Fields Then, to me asur e maximum p ower , the T est Set sets Sect or A power t o - 104 dBm/ BW , turns the Call Drop T imer “Off” , and sends “Always Up” power cont rol bits to the mobile stati on, usi ng a p roced u re simil ar to th e EIA / TIA I S-98 te st “Maximum RF Out put Powe r”.
298 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Then, to me asur e maximum power , the T est Set sets Sect or A power t o - 104 dBm/ BW , turns the Call Drop.
299 Chapter 4, Des cription of Field s Fields Mobile Power Mode This fi eld allows selecti on between two CDMA Channel Power measure ment modes, provi ding for Channe l Power measure ments without a call connec ted.
300 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Mobile Pwr This fiel d is di splayed when the Mobile Power Mo de fi el d is se t to “Use r”. When this f ield is d isplayed, the T est Set require s an esti mated mobile station power level t o make CDMA Channe l Power measu rements.
301 Chapter 4, Des cription of Field s Fields Model: This fiel d is used to spec ify the type of printe r use d. If your printer is not li st ed in the Choices menu when you se lect thi s field, configur e your pri nter to e mulate one of th ose that is listed.
302 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields MS Id This fiel d i s us ed to ent er th e ident ific ation num ber of the m obile statio n. Th e MS Id field has two fi elds. Th e content of the lo wer fiel d is au tomatical ly update d upon succe ssful completi on of a mobil e stati on registra tion.
303 Chapter 4, Des cription of Field s Fields Exampl e OUTPUT 714;"CALLP:NMOD ’PHONE NUM’" OUTPUT 714;"CALLP:PNUM ’5099906092’" OUTPUT 714;"CALLP:NMOD ’MIN’" .
304 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Screens Where Field is Present CDMA SHOR T MESSAGE SER VICE T able 13 Integers and T ext Messages Integer V a.
305 Chapter 4, Des cription of Field s Fields MS Ack Rcvd (annunciator) If the mobile sta tion succ essfully receive s the SMS mes sage, it s ends an SMS receiv ed acknowled gment to the T est Set , lighti ng the MS Ack Received annuncia tor . GPIB Ex ample “STAT:CSMS:EVEN?” queries the CDMA SMS Status Registe r Event Regist er.
306 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields MS Database This fi eld displ ays infor mation obtained f rom the mobil e stati on during regist ration.
307 Chapter 4, Des cription of Field s Fields • Pwr Step - MIN_PWR_CNTL_STEP. Minim um closed loop power con trol step size supporte d by mob ile stat ion.
308 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields MS FER Report Interval This fi eld s ets t he number of f rames the mobi le st atio n will count befor e repo rtin g fram e err o r rate ( FER ) when the by # frames field is On .
309 Chapter 4, Des cription of Field s Fields GPIB Ex amples “DISP CCNT;CDMA:MOBile:MSID ‘AUTO’“ select s “auto mati c” ent ry of the mobi le s tatio n’s MIN a nd Phone Number t hrou gh regist ration.
310 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Network ID This fi eld allows entry of the cell site’ s network identif ication (NID). GPIB Exampl e “DISP CCON;CDMA:CELL:CONFigure:NID 0“ sets t he network i dentifi cation of the simul ated CDMA cell site to 0.
31 1 Chapter 4, Des cription of Field s Fields NGHB Fq (Ch) This fie ld allows t he user to spec ify th e NGHBR_FREQ in s ending t he (Ext ended Neighbor L ist Message (ENLM) . GPIB Ex ample “CDMA:CELL:CONF:NBFR 243” sets t he neighbor frequency channel number in t he custom n eighbor li st.
312 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Nom Power This fi eld allows entry of the nominal transmit power of fset (NOM_PWR) . GPIB Exampl e “DISP CCON;CDMA:CELL:CONFigure:NOMinal:POWer 0“ sets NOM_PWR to 0.
313 Chapter 4, Des cription of Field s Fields No Pk/Avg This fiel d is di spl aye d when the Controls f ield is set to Auxiliary . This fi eld perfor ms two fun ctions: p eak hold, an d video ave raging. Pk Hold (peak hold) pre vent s the Spect rum Anal yzer fro m erasi ng the previous trace e ach time i t sweeps.
314 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Normalize This fi eld is di splayed when the Controls field i s s et to Auxiliary . This area perfor m s th ree displ ay operat ions: • Save B saves the curr ently-displayed trace for the A-B oper ati on.
315 Chapter 4, Des cription of Field s Fields Notch Freq This fi eld sets the cen ter frequen cy for the variabl e frequenc y notch filter . It is typical ly used f or distor tion and S INAD measurem ents at fre quencies b elow or above the standard 1 kHz notch filter .
316 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Notch Coupl This fi eld selects if the Notch Freq setting of the AF ANAL YZER scree n is coupled t o t he AF Gen1 Freq setti ng. W hen s et to None , the no tch fi lter and A F Generato r 1 do not int eract.
317 Chapter 4, Des cription of Field s Fields Num Pages This fi eld allows entry of the number o f page attempts the T est Set wi ll perf orm when a cal l is made from th e T est Set . The power -up or pres et def ault val ue is on e page att empt. GPIB Ex ample “CDMA:CELL:CONF:NPAG 2“ sets t he Num Pages fi eld to two .
318 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields OCNS (Sector A Power ) This fi eld displ ays OCNS (Ortho gonal Channe l Noise Simul ator). Th e W alsh code can b e specif ied for OCNS, bu t OCNS power is not settable.
319 Chapter 4, Des cription of Field s Fields OCNS (Sec tor B Powe r) This fi eld displ ays Orthogo nal Channel Noise Simula tor (OCNS ). The W alsh Code can al so be spec ified for OCNS, but OCNS p ower is not settabl e.
320 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Open Loop Time Response (Execute) This fi eld is di splayed on the OPEN LOOP TIME RESPONSE screen when “Main” is selecte d in the "Con trols (Open Loop Time Respon se)" field on pa ge 212 .
321 Chapter 4, Des cription of Field s Fields Order This fi eld is use d to send a n order type mobil e statio n control message on t he forward voi ce chann el to the mobile sta ti on.
322 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Syntax :NORDer <’><NAMPS order message><’> :NORDer? Example OUTPUT 714;"CALLP:NAMP.
323 Chapter 4, Des cription of Field s Fields Output Atten Hold This fi eld, when set to On , pr events t he output a ttenuat ors in th e T est Set fr om switchi ng in and out , avoidin g temporary loss of the outp ut signal as the RF Power l evel is changed.
324 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Output Por t This fi eld selec ts the RF ou tput port on the T est Set. • RF Out selects the RF IN/OUT port on the Test Set’s front panel and disp lays the RF Out field for enterin g CDM A forward channel path los s.
325 Chapter 4, Des cription of Field s Fields Output Results To This fi eld selec ts where t est resu lts are output. The underline d entry i s the act ive choice. • CRT displa ys test results o n the T e st Set’ s CR T . • Printer displays test results on the T est Set’ s CR T and output s them to a printer .
326 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Page (annu nciator) When li t, the Page an nunciator indic ates that t he mobile s tation c onnected t o the T est Set i s current ly being p aged on the forward co ntrol cha nnel.
327 Chapter 4, Des cription of Field s Fields Page Send This fi eld is use d to speci fy the message(s ) to be se nt on the pa ging channe l. GPIB Ex ample “CDMA:CELL:CONF:PAGE:SNDMode ‘AO-AK/ G P’” specif ies the mes sage(s) to be sent .
328 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Page Sent (annunciator) This annu nciator l ights when the Call/ Page ke y is press ed. If th e call pr oceeds to connecte d, the Pa ge Sent an nu nc ia tor r em ain s lit un til t he cal l is te r mina ted.
329 Chapter 4, Des cription of Field s Fields Pam Size This fi eld allows entry of the acces s chann el preamble l ength (P AM_SZ). GPIB Ex ample “DISP CCON;CDMA:CELL:CONFigure:PAMSize 10“ sets PAM_SZ t o 10. Operating Considerations This fi eld sets the length of th e access p robe preambl e.
330 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Parity This fi eld specifies the se rial communi cation pa rity setting wh en usin g the rear - panel se rial por t. This settin g is reta ined w h en th e inst rumen t is tur ned off.
331 Chapter 4, Des cription of Field s Fields PCMCIA This fi eld provi des re-fo rmatting of PCMCIA cards. GPIB Ex ample “DISP IOC;:CONFigure:PCMCia:CARD:STATus?“ display s the I/O CONFIGURE scree n and quer ie s the curr ent sta tus of the PCMI- CA card sl ot (No c ard or card i nserted.
332 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Phs Error This fi eld is di splayed when Freq Error is sele cted fro m the list of choice s availa ble when t.
333 Chapter 4, Des cription of Field s Fields Pilot (Sect or A Power) This fi eld allows the en try of pilot E c , the pilot c hannel ene r gy per PN chip relati ve to the Sector A powe r . GPIB Ex ample “DISP CGEN;CDMA:CELL:ASECtor:PILot:POWer -7dB“ sets Se ctor A pil ot power to − 7 dB.
334 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Pilot Inc This fi eld allows entry of the incr ement betw een the pi lot PN of fsets of the Neighbor S et pilots.
335 Chapter 4, Des cription of Field s Fields Pil ot Me as (Clea r) The Pilot Meas (Clear) field clears the contents of the CDMA Mobile Reporti ng table. GPIB Ex amples “DISP CMOB;CDMA:MOBile:PILot:CLEar“ clears the conten ts of the CDMA Mobil e Reporti ng table.
336 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields PN Offset This column in the C D MA M o bile R epor ting ta b le list s the P N Offsets for all pilots being tr acked by the mobile st ation.
337 Chapter 4, Des cription of Field s Fields Programmi ng E xample 10 ! RE-STORE "C:WENDYLREAD_MRT" 20 CLEAR SCREEN 30 DIM Pil_str$[500] 40 OUTPUT 714;"CDMA:MOB:PIL:STR?" 50 ENTER.
338 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields PN Offset (Sect or A Power) This fi eld allows entry of the PN seque nce of fset for all Sector A co de channels . GPIB Exampl e “DISP CGEN;CDMA:CELL:ASECtor:PNOFfset 0“ set s th e pilo t PN offset index to 0 .
339 Chapter 4, Des cription of Field s Fields Port/Sweep This cont rol performs two functions: • The upper f i eld specifies the ou tput port of the T racking Generator . • The lower field specifies whether the Tracking Generator sweeps f rom low-to-high fre- quencies ( Norm ), or from high -to-low frequ encies ( Invert ).
340 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Power Cntl Step Size This fi eld is di splayed onl y when the "Protocol" field on page 34 6 is se t to TI A/ EIA-95B. This fi eld allows entry of the foll owing close d loop power contr ol step si zes: • 1 dB • 0.
341 Chapter 4, Des cription of Field s Fields Power Meas This fi eld provi des A verage Power zer oing (when Average Power is se lected) and Channel Power cali bration (when Channel Power is sel ec ted ). • Calibrate Refer to the Chan Power field d escript ion, on page 197 .
342 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Screens Where Field is Present CDMA CALL CONTROL CDMA TRANSMITTER POWER RANGE TEST CDMA CELLULAR MOBILE TRANSMITTER TEST Power Step This fi eld allows entry of the power i ncrement ( PWR_STEP).
343 Chapter 4, Des cription of Field s Fields Print Data Destination This fiel d w ill be use d in the future to s el ect wheth e r th e d ata is forma t ted specif ically f or print ers or fo r some other device ( such as a c omputer). At this time the only se lection is Printer .
344 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Priority This field s ets th e P riori ty Ind icato r para me ter i n S M S mes sage s. None Normal Interactive Urgent Emergenc y GPIB Exampl e "CDMA:SMS:TERM:PRI ‘Urgent’" sets t he Priority par ameter to “Urge nt”.
345 Chapter 4, Des cription of Field s Fields Privacy This fi eld sets the Privacy Indi cator paramet er in SMS m essages. The cho ices availa ble are: •N o n e •N o R e s t r i c t • Restricted • Conf identl • Secret GPIB Ex ample "CDMA:SMS:TERM:PRIV ‘Restricted’" sets t he Privacy param eter to “Restric ted”.
346 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Program This field d ispla y s prog ram in format ion fo r the fi le cho sen in t he Select Procedure Filename: field. Screens Where Field is Present TESTS (Main Menu) Protocol This fi eld provi des a choic e of these prot ocol sele ctions.
347 Chapter 4, Des cription of Field s Fields Pwr Dwn Re g This fi eld selec ts whether to perfo rm power down r egistra tion. GPIB Ex ample “CDMA:CELL:CONF:PDRegister ‘Off’” enables or disable s power down regist ration. Operating Considerations This is an immedia te acti on toggle f ield.
348 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Pwr Lvl: - The Pwr Lvl: fie ld is div ided into two field s: Left-Hand Field The left -hand field d isplays t he mobile stat ion’ s out put power level assignment fo r the v oice chann el cur rently be ing used by the T est Set and the mobile station.
349 Chapter 4, Des cription of Field s Fields Screens Where Field is Present CALL CONTROL Pwr Up Reg This fie ld de termin es if, at pow e r-up, the mo bile s tatio n will at tempt t o regi ste r with the T est Set.
350 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields RAND The 32-bi t value en tered in this f ield, Rand om Challe nge V alu e, will be used by the mobil e stati on during a uthentic ation proc edures. RAND is sent to t he mobile stati on on the Pag ing Channel Access P arameters Message.
351 Chapter 4, Des cription of Field s Fields RAND_B RAND_B is the 1 6 least s ignific ant bits of RAND and is enter ed as a 4-di git hexadeci mal value. T he mobile statio n stores a nd uses th e most rece nt versio n of RAND in the au thentication p rocess.
352 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields RANDSSD_1 RANDSSD_1 is the 24 most sign ificant bits of the random nu mber is sued by the base st ation in t he SSD Update O rder . RANDSSD_1 is ent ered as a 6-digit hexadeci mal value.
353 Chapter 4, Des cription of Field s Fields RANDSSD_3 RANDSSD_3 is the 8 least s ignific ant bits of the ra ndom number issued by t he base st ation in t he SSD Update O rder . RANDSSD_3 is ent ered as a 2-digit hexad eci mal val ue. The :RAND:SSD3 co mmand is us ed to cont rol this field.
354 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields RANDU RANDU is the 24 -bit random number i ssued by t he base st ation in the Unique Challenge Ord e r . RANDU is entered as a 6 -digit h exadecimal val ue. RANDU is user def inable.
355 Chapter 4, Des cription of Field s Fields Screens Where Field is Present CONFIGURE Rcv Pace The recei ve pace f ield is u sed when rec eiving se rial dat a. • Xon/Xoff lets the T est S et “talk” to the transmitting device to alter the rate of the data bein g sent.
356 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Ref Level Refe rence level sets th e am plit ud e re fe ren c e lev e l for th e to p l ine of the di spl ay . All si gnal s disp laye d are re fere n ced to this li ne.
357 Chapter 4, Des cription of Field s Fields Reg Period This field se ts the int erval for time r-based re gistr ation s. The def ault v alue fo r this field, 29, provide s regist ration inte rvals of approxi mately 12 s econds. Sel ecting higher n umbers increases this interval .
358 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Register (Analog) This field is used to in itiate a regis tratio n of th e mobil e statio n tha t is conne cted t o the T est Set.
359 Chapter 4, Des cription of Field s Fields Operating Considerations Mobile station regis tration can occur as a result of t he following events: • The mobi le station power is cycled • The “Register” feature is selected by selecting this field or sending the GPIB command show n a bove .
360 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Registering (annunciator) This annu nciator l ights when the Reg ister fiel d is sel ected. The a nnunciato r goes out w hen t he re gist ratio n is su ccess ful, when the r egist ratio n atte mpt ti mes o ut, o r when the En d/Release key is pressed.
361 Chapter 4, Des cription of Field s Fields Release Time This fi eld displ ays the t ime period between the -20 dB an d -3 dB point s of the falli ng edge of an e nsemb le ave rage of CDMA RF burst s. Th is fi eld will displ ay a value onl y after a gated powe r measuremen t is made.
362 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Release This fi eld is used to te rminate an ac ti ve voice chan nel con nection with th e mobile statio n.
363 Chapter 4, Des cription of Field s Fields RF Anl Freq (CDMA S wept Power Measure ment) This fi eld allows the user to set the fre quency of t he T est Set RF a nalyzer . GPIB Ex ample “RFANalyzer?FREQuency 836.520000“ select s the RF anal yzer fre quency.
364 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields RF Channel (CDMA) This field is dis play ed on th e scr eens listed belo w whe n the RF Display fiel d on the CONFIGURE screen is set to Chan . GPIB Exampl e “DISP CCNT;CDMA:RFCHannel 283“ select s channel 283.
365 Chapter 4, Des cription of Field s Fields RF Chan Std This fi eld is di splayed when Chan is se lected i n the RF Disp lay fiel d on the CONFIGURE screen. Use th e RF channel standard field to selec t the channel st andar d for the r adio- under -test.
366 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Ta b l e 1 6 M o b i l e Te s t C h a n n e l Stand ard V alid Channe l Numbers Offset Freq (MHz) Chan nel Sp.
367 Chapter 4, Des cription of Field s Fields RF Cnt Gate RF counter gate spec ifies ho w long the RF c ounter samples t he signal before display i ng the frequenc y . Specifying a shorter gate ti me may enable y ou to see frequen cy fluctu ations t hat might no t be seen u s ing a longer gat e time.
368 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields RF Gen Freq This fi eld is displaye d on the screens l isted below when the RF Displa y field on the CONFIGURE screen is set to Freq . This fi eld sets the RF Generator’ s (or CDMA generat or ’ s) frequency .
369 Chapter 4, Des cription of Field s Fields RF In This fi eld is used to indicat e revers e channe l path lo sses or ga ins between t he mobile statio n and the RF I N/OUT port. •E n t e r a positive value to indicate a gain (such as amplifier gain).
370 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields RF Offset This fi eld is di splayed when the RF Displ a y field has Fre q select ed. This fi eld enable s/disabl es the RF Ge nerator − RF Anal yzer frequen c y offset specif ied in the (Gen)-(Anl) field bel ow it.
371 Chapter 4, Des cription of Field s Fields RF Power This fi eld di sp lays I o , th e tot al powe r spec tral densi ty of Sector A power , Sector B power and A WGN. GPIB Ex ample “CDMA:RFP?” queries the RF Power l e vel. Operating Considerations RF Power is cont roll ed by set tings in the Sector A Power , Sector B Power , and AWGN field s.
372 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Rgstr SID This fie ld allo ws ent ry of the cell si te’ s alter nate sy stem iden tifi ca tion (SI D), used only for registration.
373 Chapter 4, Des cription of Field s Fields Screens Where Field is Present CALL CONTROL RX/TX Cntl This func tion cont rols aut omatic screen cha nges betwee n the RX TEST and TX TEST scree ns during r adio tes ting.
374 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Run Selec tin g this fi eld r uns th e IBA S IC pr ogra m. Screens Where Field is Present TESTS (IBASIC Con troller) Run Test Selecti ng this f ield loa ds and runs the test chosen in the Select Procedure Filename: field.
375 Chapter 4, Des cription of Field s Fields SAT: The SAT: fie ld is divide d into two field s: • The left-hand field displays the current SAT ton e frequency assignment for the current voice channel being u sed by the Test Set and the mobi le station.
376 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields SAT Deviation The SAT Deviation measu reme nt is mu ltip lexed on the sam e field with th e FM Deviation mea surement. When the CALL CONTROL scree n is select ed, SA T Deviati on will be displayed automatic ally .
377 Chapter 4, Des cription of Field s Fields Sat Tol This fi eld is di splayed onl y for NAMPS syst em type. This fi eld is use d to sele ct the Sat tole rance. Whe n set to Na rrow the Sat limi t is one of th e three vali d Sat tone s ± 10Hz. When s et to Wide the Sa t limi t is defin ed at 0 to 7 000 Hz.
378 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Save/Recall This fiel d specifies whi ch memory device th e T est Set access es when the save and recal l fun ction s are u sed. • Internal is a sect ion of in ternal RAM.
379 Chapter 4, Des cription of Field s Fields Sc Priori ty This fi eld allows the user to specify the s earch pri ority in se nding the Extende d Neighbor L ist Message (ENLM) . GPIB Ex ample “CDMA:CELL:CONF:SCPR ‘Medium’” sets t he search pr iority level in the cus tom neighbo r list.
380 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Sctr A Pwr This fi eld provi des contro l of the Sector A forward CDMA c hannel gen erator output l evel. Forwa rd CDMA channel po wer is expressed in units of dBm in a 1.
381 Chapter 4, Des cription of Field s Fields Sctr B Pwr This fi eld provi des contro l of the Sector B forward CDMA chan nel generator powe r level (A lso re ferre d to as I or ). Forward CDMA channel power is expr essed in unit s of dBm/1. 23 MHz bandwidth .
382 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Selec t Proc edure Loca tion This fi eld is use d the sel ect the l ocation o f the proc edure to l oad. Proced ures can be loade d from disk, card, ROM, or RAM.
383 Chapter 4, Des cription of Field s Fields Send Msg (CD MA Swept Powe r Measureme nt) This fi eld allows the user to specify whethe r a Pilot Measurem ent Request Order (PMRO), Extend ed Handof f D.
384 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Sensitivity RF Analyzer sensi tivit y adds a bout 6 dB of sensi tivi ty for the ANTENNA IN por t when High is selected.
385 Chapter 4, Des cription of Field s Fields Serial_9 In This fi eld selects th e destination o f characters r eceiv ed by the T est Set on the serial port. IBASIC is used to allow the IBASIC controller to read the serial port while a program is runn ing.
386 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Set Message This fi eld is use d to sele ct the desired forward con trol cha nnel or fo rward voic e channel m essage t o be displ ayed. The :MESSage c ommand is used to contro l this fie ld.
387 Chapter 4, Des cription of Field s Fields EXT PR OT Standar d Equivale nt: FC C Mobile Station Control Message Message Fields: EF , MIN2, MSL, MST , Parity , SCC, T1 T2 FVCBSCon Standard Equiv ale.
388 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields MRI ME S Standard Eq uivalent: MR I Parameter Mess age Message Fields: BER, BER LSB, DSCC , EF , OE, ORDER, O.
389 Chapter 4, Des cription of Field s Fields NTHO MES Standard Eq uivalent: T ACS Narrow Handof f Message Message Fields: CHAN, CTYP , BIT12, DSCC, OE, PDSCC , RSVD, T1 T2, VMAC NTMS FVC Standar d Eq.
390 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields SPC WORD1 Standard Equivalent: System Parameter Overh ead Message W ord 1 Message Fields: DCC, NA W C, OHD, P.
391 Chapter 4, Des cription of Field s Fields CMAC C ontrol m obi le atte nuatio n fiel d. Ind icate s the mobile stati on pow er lev el asso ciated wit h revers e control channe l. CMAX-1 CMAX is the number of access c hannels i n the syst em. CPA Combine d paging/a ccess fi eld.
392 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields OHD This field d isplays t he overhe ad message t ype. • A ‘100’ ind icates a global action message. • A ‘110’ indicates that this is the first word of the system overhead parameter message.
393 Chapter 4, Des cription of Field s Fields REGH Registr ation fi eld for h ome statio ns. REGID R eg ist ra tion ID fiel d. REGINCR Regi stra tion i ncrem ent f ield . REGR Regist ration f ield for roamin g statio ns. RSVD Reserved for fut ure use.
394 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Settling This fie ld selects the set tling time for making AF measurements . Lower frequency signals require addition al settl ing time ( Slow ). Higher frequency measure ments requ ire les s settl ing ti me ( Fast ).
395 Chapter 4, Des cription of Field s Fields SID MSB This fi eld is used to set the system i dentifi cation nu mber (SID) of the T est Set. The SID field is an immedi ate acti on field. I f the fiel d is selec ted and chang ed, the signali ng messa ge(s) being sent on the forwar d control channe l are immediat ely chan ged.
396 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields SINAD This is the d efa u lt mea surem ent for thi s fie ld.
397 Chapter 4, Des cription of Field s Fields SMS Se nt (annunc iator) This annu nciator i ndicate s that th e SMS message has been sent . The annu nciator should l ight when t he Execute is sel ecte d in the Send Message fi eld.
398 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields SNR When set to SNR , thi s field disp lays the signal to noise ratio of the input audio signa l.
399 Chapter 4, Des cription of Field s Fields Soft er H ando ff This fi eld controls so fter handof fs. GPIB Ex ample “CDMA:CALL:SHAN ‘ON’” begins a softer ha ndoff. Operating Considerations The Connected annunciato r in t he Call Status fi eld must be lit before a s ofter handof f can be pe rformed.
400 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Soft er Hando ff (annunciat or) This annun ciato r is lit when On is sel ected in the Softer Handoff field. Whe n the hando ff is e nded, the Softer Handoff annunciator goes out.
401 Chapter 4, Des cription of Field s Fields Span This field is dis played whe n the Controls field is set to Main . This fi eld sets t he span of f requenci es to be di splayed on the scre en. GPIB Ex ample “DISP CSP;CSP:SPAN 3 MHZ“ sets t he frequenc y span to 3 M Hz.
402 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Speaker Vol Spea k er V olume en able s/dis ables the in strum e nt’ s in tern al spe aker . Wh en Pot is select ed, the VOLUME c ontrol kno b operate s normally .
403 Chapter 4, Des cription of Field s Fields Sque lch This set ting det ermines th e squelch o peration when demodu lating FM, AM or SSB signal s. Three se ttings a r e available: • Pot uses the front-panel SQUELC H knob for s quelch level adjustment .
404 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Srch Win A This fi eld allows entry of the searc h-windo w size for th e active set and candidat e set . GPIB Exampl e “DISP CCON;CDMA:CELL:CONFigure:AWIN 5“ sets se arch-windo w A to 5.
405 Chapter 4, Des cription of Field s Fields Srch Win N This fi eld allows entry of the searc h-windo w size for th e neighbor set. GPIB Ex ample “DISP CCON;CDMA:CELL:CONFigure:NWIN 5“ sets se arch-windo w N to 5.
406 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Srch Win R This fi eld allows entry of search-wi ndow size f or the re maining set. GPIB Exampl e “DISP CCON;CDMA:CELL:CONFigure:RWIN 5“ sets se arch-windo w R to 5.
407 Chapter 4, Des cription of Field s Fields SSDA The :S SDA command is onl y availab le through the remote users in terface. No field i s displa yed for t his funct ion on the test set .
408 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields SSDB The :S SDB command is only avail able thr ough the r emote us ers inte rface.
409 Chapter 4, Des cription of Field s Fields SSD Updat e NOTE: An SSD update can be per formed on the pag ing/acces s channels or on the traf fic cha nnel . When SSD Update Execute is selected, an SSD Update Mess age is sent to the mobile st ation, an d the SSD Update annuncia tor is lit.
410 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields SSD U pdate ( annunc iator) When lit, this annun ciator indi cates th at an SSD Updat e is in progres s.
41 1 Chapter 4, Des cription of Field s Fields NOTE: If no values are disp layed in the CDMA Mobile Repo rting table, the query ex ample shown above will return on ly the line feed character.
412 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Operating Considerations for Status Field When a ca ll is made , the mobil e statio n’ s Active li st is i nitiali zed to con t ain only Sector A.
413 Chapter 4, Des cription of Field s Fields Status (CDMA Authentication) This col umn in the authe nticati on result s table list s the s tatus (p ass or fa il) of the parame ters th at are u sed to au thenticate a registr ation, page, or originatio n.
414 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Step s This fi eld allows entry of the numbe r of power c ontrol bi ts that the T est Set will send to t he mobile s t ation through the power co ntrol sub channel whe n the Execute field is selec ted.
415 Chapter 4, Des cription of Field s Fields Operating Considerations The T est Set measures t he time re sponse of the mobil e station’ s output p ower in response to a ste p change in the T est Set’ s output power . T est stan dards req uire that se ctor A power ( "Sctr A Pwr" field on page 380 ) init iall y b e set t o -60 d Bm.
416 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Strength This column in the C D MA M o bile R epor ting ta b le list s the p ower level most recen tly mea sure d and re porte d by th e mobi le sta tion fo r each p ilot th e mob ile sta tio n is cu rre n tly t r a cki ng .
417 Chapter 4, Des cription of Field s Fields 210 NEXT I 220 END Screens Where Field is Present CDMA MOBILE REPOR TED PILOT STRENGTH Swept Pwr (CDMA Swept Pow er Measurem ent) This fi eld allows for armin g the swept power meas urement. GPIB Ex ample “CDMA:SWEPtpower:TRIGger[IMMediate]“ arms the me asurement.
418 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields System ID This fi eld allows entry of the syste m identificati on (SID). GPIB Exampl e “DISP CCON;CDMA:CELL:CONFigure:SID 0“ sets t he system i dentifi cation of the simul ated CDMA cell site to 0.
419 Chapter 4, Des cription of Field s Fields System Type (CDM A-to-CDMA or CDMA -to-Analog Handoff) This fi eld selec ts the t ype of syst em that th e T est Set will at tempt to ha ndoff the mobile st at ion to when the field titled "Execute (Handoff)" on page 25 0 is sel ect ed.
420 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields T_A dd This fi eld allows entry of the pilot detecti on thres hold T_ADD.
421 Chapter 4, Des cription of Field s Fields T_D rop This fi eld allows entry of the pilot drop thr eshold (T_ D ROP). GPIB Ex ample “DISP CMOB;CDMA:MOBile:TDR 40“ sets T_DROP t o 40. Operating Considerations When the Softer Handoff annunciator is l it, Sector A a nd Sector B a re added to the mobile stati on’ s Ac tive l ist.
422 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields T_TD rop This fi eld allows entry of the handof f drop timer’ s value (T_DROP) .
423 Chapter 4, Des cription of Field s Fields Test Pro cedur e Run Mo de This fi eld selec ts how the t est will be run. The underlin ed entry i s the act ive choice. • Continuous runs th e tests i n the test sequence on e after anot her with out stop ping.
424 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields This fi eld is dup licated on the CDMA CALL CONTROL screen. GPIB Exampl e “DISP CRXT;STATus:CDMA:CONDition?“ queries the CDMA con dition re gister.
425 Chapter 4, Des cription of Field s Fields Failed (annunci ator) This annu nciator i s lit whe n an FER test has fail ed. An FER test fails wh en the measured F ER is greater tha n the tar get FER with the s pecifie d confiden ce level, acco rding to the crit eria es tabli she d by the con fi den c e lev e l and F ER specif ication.
426 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Time (Configur e) This fi eld sets the ti me-of-day for the inst rume nt’ s 24 hour clo ck. (Exa mple, 4: 53 PM is ente red 16:53 ) Operating Considerations The in ternal c lock sti ll funct i ons when the i nstrume nt is tur ned off .
427 Chapter 4, Des cription of Field s Fields Time/div This fi eld selec ts the hor izontal sweep time per divis ion. Operating Considerations The time- per -divisi on is sele cted fro m a list of choices.
428 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Time Offset (Ne gative) This fi eld allows setting of a negative tim e of fset for measuring CD MA signa ls.
429 Chapter 4, Des cription of Field s Fields TM Rho This fi eld displays th e mobile stat ion’ s measure d waveform quality factor , Rho. Rho can be me asured in eithe r of two ava ilable mod es. • Traffic Rho Traffic Rho measures Rho when the mobile station is tr ansmitting a reverse traf fic channel.
430 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields To Screen These fi elds are used to cho ose which of the T est Set scre ens to dis play .
431 Chapter 4, Des cription of Field s Fields Tot al RA M This fi eld displ ays the t otal amo unt of RAM avai lable for IBASIC pr ograms and save /rec al l reg i ster s. Screens Where Field is Present CONFIGURE Trace (CDM A Swept Power Measuremen t) This fi eld clears the m easu rement from the di splay .
432 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Traf fic ( Sect or A Powe r) This fi eld allows the entr y of Secto r A traf fic E c /I or , the ener gy per PN chip for the forw ard tr affic c hann el le vel relati ve to the t ota l sec tor po wer .
433 Chapter 4, Des cription of Field s Fields Traffic Data Mod e This fi eld selec ts the de sired service option. “Rat e set 2” r efers t o vocoders that operate at 14.
434 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Traffic Rho See the TM Rho fi eld descri ptio n, on p age 429 .
435 Chapter 4, Des cription of Field s Fields Trig -Delay The t rigge r d elay i s used to spe c ify th e time re lati o nship b etwe en the tr igger and display e d signal. • Positive values delay the measur ement trigger by a specific period . The delayed trigger point is the left edg e of the screen.
436 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Tune Fr eq This fi eld is displaye d on the screens l isted below when the RF Displa y field on the CONFIGURE screen is set to “Fre q ”. RF analyze r tune fr equency se ts the ce nter fre quency for the RF signa l to be analy zed .
437 Chapter 4, Des cription of Field s Fields TX Po wer T ransmitte r Power measu res RF power at the RF IN/OUT port. Operating Considerations Only the RF IN/OUT por t can be used for mea suring TX Power . When t he Input Port is se t t o Ant , four dashes (- - - -) ap pear in plac e of digits for this measurement .
438 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields TX Po wer This fi eld displ ays the mea sured RF power of the ca rrier b e ing transmitt ed by the mobile stati on. Fo ur das hes (- ---) in dicat es tha t t here i s no ca rrier p resen t to meas ure.
439 Chapter 4, Des cription of Field s Fields TX Pwr Meas The tran smitter power measure ment fiel d speci fies how t ransmitte r power measurement s are made: • Peak can be used to m easure AM, FM, and un-modulated (CW) signals. • Sample can be used to measure FM or CW signals with increased measurement speed.
440 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields TX Pw r Zero The TX Pwr Zero func tion establis hes a 0.0000 W r eference for measur ing RF power at the RF IN/OUT port. The TX Pwr Zero field is imp orted fr om the RF ANALYZER screen and is pro grammed ex actly as it is on i ts home scr een.
441 Chapter 4, Des cription of Field s Fields Type The T ype field allows you t o set the FOR_TRAFFI C and REV_TRAFFIC parame ters in the base sta tion to ‘0’ (None ), or ‘1’ (Prim ary). It appear s only when Serv ice O ption 6 or Serv ice O ption 14 a re selec ted in the T r affic D ata M ode f ield .
442 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Operating Considerations A Unique Chall enge ver ifi es that th e mobi le stati on and T est Set posse ss the s ame sets of Shared Secr et Data ( SSD).
443 Chapter 4, Des cription of Field s Fields Upper Lim it This fi eld is use d to set t he upper l i mit to be compare d with the measured re sults. If the meas ur ed res ult is above th is limi t, the test w il l fai l.
444 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields VC Order This fi eld is use d to send a n order on the for ward voice channel t o the Mobile Statio n with authe nticati on activ e. The VC Order f ield is only visible when auth enticati on is act ivate d and the mob ile is as signed a voic e channel.
445 Chapter 4, Des cription of Field s Fields Vert/div V ert ical sensiti vity sets the ve rtical amplit ude per division . Operating Considerations The value for this field i s select ed from a l ist of ch oices. Depending on the AF Analy zer ’ s AF Anl In sett ing, th e unit s for thi s field may be in V olts, k Hz, or Per cent (AM) .
446 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields Walsh (Sector A) This col umn of fiel ds displa ys the W alsh code f or the Pi lot, Sync, a nd Pagin g channels . and provi des an ent r y field for T raf fic and OCNS W alsh codes.
447 Chapter 4, Des cription of Field s Fields Xmt Pace The t ransm it pa ce fi el d is u s ed wh en tra nsm itting ser i a l dat a. • Xon/Xoff lets the receiving device “ talk” to the T est Set to alter the rate of the data bein g sent. • None disab les the Xon/Xof f functio n.
448 S:agilente82 85REFGUIDEMANUALfields.ch p Chap ter 4, Des cri ptio n of F ield s Fields.
Index Index 449 - - - - meaning of , ACP level meas ureme nt , 15 3 meaning of , squelch , 403 meaning o f, TX power meas ureme nt , 15 3 , 437 Symbols *Clr All* , 306 *RST , 49 Numeric s 1 kHz Tone D.
450 Ind ex Index AMPS Call Control screen. See Also Ca ll Contr ol scree n AMPS system type , 419 AMPS-TACS simulat ed syst em , 418 Analo g Me as scr e en AF Anl In , 155 AF Freq , 156 AF Gen1 Freq ,.
Index Index 451 C Op Modes , 306 Calibrate fiel d (P ower Meas) , 341 calib ratio n channe l power m e asur ement , 198 , 341 spectrum analyze r , 132 call answer , 31 disconnec t , 35 paging , 34 Cal.
452 Ind ex Index Esc Mode , 248 Ext NG HB , 257 Init P o wer , 274 Max Re q Seq , 29 4 Max Rsp Seq , 294 Network ID , 310 Netwrk C ode , 310 NGHB Fq (Ch) , 311 Nom P ower , 31 2 Nom Pwr Ext , 312 Num .
Index Index 453 Length , 282 Message D ata Mode , 295 MS Ack Cause Code , 303 MS Databas e , 306 Orig Addr , 322 Priority , 344 Privacy , 345 Send Msg , 382 SMS In Progress , 397 Svc Opt 14, Tra ffic .
454 Ind ex Index Connect annunc iator , 209 Connected an nunciator Call Status , 210 T est Status , 423 connecto rs MODULATION INPUT , 74 Cont/Single fi eld , 21 1 Continue fiel d , 210 control channe.
Index Index 455 electron ic seri al numb er (ESN) , 249 emf voltage , 368 Encoding fi eld , 244 End/Release key , 35 Enter ASCII Data field , 245 Enter Hex Data field , 245 Enter key , 35 Enter Proced.
456 Ind ex Index non-program mable front-pa nel functions , 61 GPIB Ad dress field , 272 GPIB conne c tor , 73 GPIB ope ration, s quelch effects , 403 Grid (CDMA Swe pt P owe r Meas urement) f ield , .
Index Index 457 TX test (CDMA) , 60 unit-of-mea sure , 58 up-arrow , 57 USER , 64 Ye s O n / O f f , 56 KOR PCS proto col , 346 L leak age ACP meas urement , 362 Length field , 282 level ACP , 153 AF .
458 Ind ex Index MS Ack Cause Code , 303 MS Ac k Received a nnunciator , 305 MS FER field , 307 MS F ER k ey , 60 MS FER Repor t Interval field , 308 MS I D fi eld , 30 8 MS I d f ield , 302 MS R epor.
Index Index 459 phone num bers , Agilent T echno logies customer support , 10 Phs Error field , 332 Pilot field (Sector A P ower) , 333 Pilot field (Sector B P ower) , 333 pilot status Active , 410 Ca.
460 Ind ex Index reverse RF power , 324 reverse voice chan nel messag e view ing , 232 orde r con firm ation mes sage , 234 revi sion nu mber firmware , 26 1 RF Analyzer scree n AC Level , 151 AF Freq.
Index Index 461 Sav e/Rec all fi eld , 378 Sc Priority (CDMA Cell Site Configurat ion) fiel d , 379 scal e f or osci llosco pe , 339 SCC (SA T color code) , 374 sche mati c diagr am s .
462 Ind ex Index SSD Update on P aging: P assed message , 409 SSD Update on Traffic: F ailed message , 409 SSD Update on Traffic: P assed message , 409 SSD_A=0 annun ciator , 406 SSDA field , 407 SSDB.
Index Index 463 Enter Proc edure Filen ame , 246 Main Menu , 285 P ass W ord , 330 Procedure Library , 345 Select Proce dureLo cation , 382 view o f , 13 9 T ests (T est P arameters) screen , 134 Main.
464 Ind ex Index second word o f called addr es s , 234 serial num ber , 23 3 X Xmt P ace field , 447 Xon/Xoff , 355 , 447 Y Y es On/Off key , 56 Z Zero fiel d (Power Meas) , 34 1 zero reference, tran.
デバイスAgilent Technologies E8285Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Agilent Technologies E8285Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAgilent Technologies E8285Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Agilent Technologies E8285Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Agilent Technologies E8285Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Agilent Technologies E8285Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAgilent Technologies E8285Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Agilent Technologies E8285Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAgilent Technologies E8285Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。