CrestronメーカーTPS-GA-TPIの使用説明書/サービス説明書
ページ先へ移動 of 56
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Operations Guide.
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, pr oduct names and tradem arks are the proper ty of their respective owners.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Contents Isys ® G-Series Touchpanel Interface: TPS-GA-TPI 1 Introduc tion ................................................................................................................... ..
.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Isys ® G-Series Touchpanel Interface: TPS-GA-TPI Introduction Features and Functions • High-performance touchpanel interface • 24-Bit Isy.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI supports dynamic graphics and text, full-m otion animations, multim ode objects and PNG translucency - all with astonishing speed. Synapse™ Crestron's exclusive Synapse Image Re ndering Algorithm enables system programm ers to produce amazing graphics - fast er and easier.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Internal Block Diagram The following diagram represents the internal configurat ion of the TPS-GA-TPI. These units feature two RGBHV inputs to receive RGBS and RGsB from a computer and two sets of three BNC connectors to receive video and HDTV (composite, S-video and component) i nputs.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI Specifications Specifications for the TPS-GA-TPI are listed in th e following table. TPS-GA-TPI Specifications SPECIFICATION DETAILS Device Su.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface TPS-GA-TPI Specifications (Continued) SPECIFICATION DETAILS Power Requirements Cresnet Power Usage 32 Watts (1.34 Amps @ 24 Volts DC) Default NET ID 03 Minimum 2-Series Control System Update File 2, 3, 4 Version 3.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI Physical Description This section provides inform ation on the connecti ons, controls and indicators available on your TPS-GA-TPI. TPS-GA-TPI Physical View (Front) TPS-GA-TPI Physical View (Rear) TPS-GA-TPI Overall D imensions (Front) 1.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface TPS-GA-TPI Overall Dimensions (Top) 16.92 in (42.98 cm) 10.68 in (27.13 cm) 9.97 in (25.32 cm) 17.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 3 RGBHV OUTPUT (1) DB15 HD female, RG.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 7 G (2) 6-32 screw, chassis ground lug 8 NET Four-position terminal block connector for data and power.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 12 RGBHV INPUT (1 – 2) (2) DB15HD female, RGB (VGA) inputs; Formats: RGBHV, RGBS and RG S B Input resolution: 640 x 480 minimum to 1600 x 1200 maximum, non-interlaced; Input levels: 0.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface 4. The eight-pin RJ-45 QuickMedia transport port accepts CAT5E/CAT6 ca rrying audio and video signals.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI Setup Network Wiring When wiring the network, consider the following: • Use Crestron Certified Wire. • Use Crestron power supplies for Crest ron equipment. • Provide sufficient power to the system.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface CresCAT-QM Cable CresCAT- QM Cable NOTE: Do not untwist the two wires i n a single pair for more than 1/ 3-1/2” (0.84-1.27 cm) when m aking a connection. The twists are critical to canceling out interference between the wires.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI QM Network Topology TPS-12G/15G-QM-L TPS-GA-TPI QM QM QM QM QM Originati on Point s Endpoint s QM Midpoint s QM-FTDC QM-MD7x2 QM-MD 7x2 QM-WM C QM-RX The TPS-GA-TPI is an origination point . Therefore, in a QM system , it would be positioned as shown above.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Upon entering SETUP MODE, the MAIN M ENU, as shown in the following illustration, displays fou r buttons: Touch Screen Calibration , Exit and Run Program , Setup , and Diagnostics .
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI Calibration Menu CALIBRATION MENU Touch Touchscreen Calibration on the MAIN MENU and then Perform Calibration on the CALIBRATION MENU. The message “Touch Upper Left ” appears centered on the panel with a cross hair in the upper l eft corner.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface SETUP MENU Interface Menu The TPS-GA-TPI communicates with a contro l system to activate comm ands or to display feedback from components within the system . The communication interface must be correctly configured or communication will not occur.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI INTERFACE MENU Two buttons adjacent to th e Cresnet ID and its displayed hexadecimal number, Down and Up , decrease and increase the Cres net ID by one, respect ively. The Ethernet Enable and Disable buttons determine the status of the interface’s Ethernet comm unications.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface “Establishing Com municat ion”, which starts on page 42 for addit ional Ethernet setup details. NOTE: The address shown for the Current IP Address is only representa tive. It does not reflect a real or suggested address.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI ETHERNET DNS SETTINGS ETHERNET WINS SETTINGS Selection of the DHCP Enable button from the ETHERNET SETUP MENU displays the DHCP opt ions Renew and Release . 20 • Isys ® G-Series Touchpanel Interface: TPS-GA-T PI Operations Guide – DOC.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface ETHERNET SETUP MENU (DHCP ENABLED) RS-232 Menu The TPS-GA-TPI interface allows for one of four RS-232 comm unication modes: • Console (i.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI RS-232 MENU General Audio Setup To open the GENERAL AUDIO SETUP menu, press the Audio button from the SETUP MENU. The GENERAL AUDIO SETUP menu offers a series of buttons that adjust the volume as indicat ed by the gauges.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface GENERAL AUDIO SETUP MENU Refer to the following table for add itional GENERAL AUDIO SETUP menu details. General Audio Setup Details GENERAL AUDIO SETUP SCREEN CONTROLS DESCRIPTION QM Output Displays the QM AUDIO OUTPUT SET UP menu.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI To open the QM AUDIO OUTPUT SETUP menu, press the QM Output butt on on the GENERAL AUDIO SETUP menu. The QM AUDIO OUTPUT SETUP m enu offers a series of buttons that adjust the Program Gain and Transmit QM ID .
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Video Setup The TPS-GA-TPI can display two full y scalable and m ovable, full mot ion video windows, each supporting sta ndard video, HDTV and hi gh-resolution RGB signals from external AV and com puter sources.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI Video Setup Details VIDEO SETUP SCREEN CONTROLS DESCRIPTION Setup Video 1 Displays the VIDEO 1 SETUP menu. By default, the VIDEO 1 SETUP menu displays video controls: Brightness, Contrast, Saturation and Hue on t he right side of the menu.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface The video menu for RGB controls consists of preset control s, color and size & position subm enus. Touching the RGB Color button enables cont rols for brightness, contrast, red, green and blue.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI Video 1 Setup Details – Video, S-Vi deo, Component and RGB (Continued) VIDEO 1 SETUP SCREEN CONTROLS DESCRIPTION Color Control (Continued) Green 1, 2 Adjusts the amount of green in the video signal.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Diagnostics Menu The Diagnostics button from the MAIN MENU contai ns controls for diagnostic tools. The diagnostic t ools should only be used under supervisi on from a Crestron customer service representa tive during telephone support .
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI • If the rack is provided with stabilizing devices, install th e stabilizers before mounting or servicing the unit in the rack. NOTE: If rack mounting is not required, rubber feet are provided for tablet op mounting or stacki ng.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Foot Placement for the TPS-GA-TPI PLACE FEET IN CORNERS Hardware Hookup Make the necessary connectio ns as called out in the illu stration that follows this paragraph. Refer to “Network Wiring” on page 12 before attaching the 4-posit ion terminal block connector.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI NOTE: For optimum performance, Crestron st rongly recomm ends using Crestron Certified CresCAT-QM cable, available from Crestron. Other high-quality/low sk ew CAT5e/CAT6 wiring m ay also be used with vary ing performance.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Text Console Commands COMMAND COMMAND SYNTAX DESCRIPTION EXTTO UCH EXTT < value> Allows you to specify the external touchscreen being used.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI 8. Calibrate t he touchscreen by selecting Functions | Setup Mode | Enter Calibration Mode in the Toolbox System Info window. USB Connection 1. Connect the RGBHV OUT to the RGB in on the touchscreen.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Programming Software Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be vi ewed in the Online Help section of the Crestron website .
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI Locating the TPS-GA-TPI (Cresn et) in the Device Library • To incorporate the TPS-GA-TPI (Ether net) into the system, drag the TPS-GA-TPI from the Touchpanels | Touc hpanels (Ethernet) folder of the Device Library and drop it in the System Views.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface C2Net Device, Slots 8 and 9 • Additional TPS-GA-TPI devices are assi gned different Net ID (for Cresnet devices) or IP ID (for Ethernet devices) num bers as they are added.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI “TPS-GA-TPI Ethernet Device Settings” Window • The ID code specified in the SIMPL Windows program m ust mat ch the Net ID or IP ID of each unit. Program Manager Program Manager i s the view where programm ers “program” a Crest ron control system by assigning signals to sym bols.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface refer to its User’s Guide and extensiv e help information provided with the software. Also refer to the help file i n VisionTools Pro-e to learn how to use it s audio tool, Sound Manager, to attach WAV files to an interface project.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI Relationship of Bits to Colors NUMBER OF BITS NUMBER OF COLORS 1 bit Black and Whit e 2 bits 4 Colors 4 bits 16 Colors 8 bits 256 Colors 16 bits 65,536 Colors (Highcolor) 24 bits 16.7 million Colors (Truecolor) 32 bits 16.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface There are two separate application s with multibyte characters – static text on butto ns and indirect text on buttons. No Isys touchpanel or interface firmware changes are required in either case.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI Uploading and Upgrading Crestron recomme nds using the latest pr ogramm ing software and that each device contains the latest firmware to take advantage of the m ost recently released features.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface TCP/IP Communication NOTE: Required for operation with a Crestron cont rol system . Ethernet Communication PC RUNNING ETHERNET CRESTRON TOOL BOX TPS-GA -TPI • Establish serial com municat ion between TPS-GA-TPI and PC.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI ( Tools | Network Devi ce Tree ) to show all network devices connect ed to the control system.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Problem Solving Troubleshooting The following table provides correct ive action for possible troubl e situations. If further assistance is required, please contact a Crestron customer service representative.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI TPS-GA-TPI Troublesh ooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Interface is not responding to Cresnet. ICMP is disabled. Enable ICMP by typing ICMP ON at the command prompt in the Toolbox T ext Console.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface consideration. Use Crestron Certi fied Wire only. If Cresnet unit s are to be daisy- chained on the run, the Cresnet power us age of each network unit to be daisy- chained must be added together t o determine the Cresnet power usage of the ent ire chain.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI Further Inquiries If you cannot locate specific i nformation or have questi ons after reviewing this guide, please take advantage of Crestron' s award winning custom er service team by calling the Crestron corporat e headquarters at 1-888-CRESTRON [1-888-273-7876] .
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Software License Agreement This License Agreement (“Agreement”) is a legal contract be tween you (either an individual or a single business entity) and Crestron Electronics, Inc.
Isys ® G-Series Touchpanel Interface Crestron TPS-GA-TPI If You are a business or organization, You agree that upon reque st from Crestron or its author ized agent, You will within thirty (30) days f.
Crestron TPS-GA-TPI Isys ® G-Series Touchpanel Interface Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandi se may be returned for credi t, exchange or service without pri or authorization from CRESTR ON. To obtain warranty service for CR ESTRON products, contact an authorized CRESTRON dealer.
Crestron Electronics, Inc. Operations Guide – DOC. 6609A 15 Volvo Drive Rockleigh, NJ 07647 (2019014) Tel: 888.CREST RON 09.07 Fax: 201.76 7.7576 Specificat ions subject to www.
デバイスCrestron TPS-GA-TPIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Crestron TPS-GA-TPIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCrestron TPS-GA-TPIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Crestron TPS-GA-TPIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Crestron TPS-GA-TPIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Crestron TPS-GA-TPIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCrestron TPS-GA-TPIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Crestron TPS-GA-TPIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCrestron TPS-GA-TPIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。