Save this manual for future reference. OWNER’S OPERA TION AND INST ALLA TION MANUAL VENT -FREE PROP ANE/LP GAS BA Y FRONT FIREPLACE CF26PR 19,000 to 26,000 Btu/Hr Remote Contr ol Ready WARNING: If the information in this manual is not followed exactly, a fire or explosion may result caus- ing property damage, personal injury, or loss of life.
2 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2.
3 105442 OWNER’S MANUAL For more information, visit www.desatech.com AUTO O F F ON PRODUCT IDENTIFICA TION LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.
4 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes.
5 105442 OWNER’S MANUAL For more information, visit www.desatech.com DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
6 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com Figure 3 - Ventilation Air from Outdoors Shown with Optional Mantel Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts.
7 105442 OWNER’S MANUAL For more information, visit www.desatech.com INST ALLA TION Note: Your Comfort Glow fireplace is de- signed to be used in zero clearance installa- tions. Wall or framing material can be placed directly against any exterior surface of your fireplace, except where standoff spacers are integrally attached.
8 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com INST ALLA TION Continued 36 5 / 8 " 25 7 / 8 " 51 3 / 4 " 26 7 / 8 " Figure 6 - Rough Opening for Installing in Corner 2. An optional blower accessory is avail- able (see Accessories , page 28).
9 105442 OWNER’S MANUAL For more information, visit www.desatech.com 13" 16" 19" 21" 2 1 /2" 6" 8" 10" Minimum Non- Combustible Material MANTEL CLEARANCES FOR.
10 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com INST ALLA TION Continued Note: If you are using a mantel with your heater, use the following instructions. If your heater is built-in, see For Built-In In- stallation on page 11.
11 105442 OWNER’S MANUAL For more information, visit www.desatech.com INST ALLA TION Continued WARNING: A licensed electri- cian must connect the wiring har- ness to electrical supply follow- ing all local codes. Electrician must provide a clamp on the box cover to secure the wiring.
12 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com CONNECTING TO GAS SUPPLY Figure 19 - External Regulator with Vent Pointing Down WARNING: A qualified ser- vice person must connect fire- place to gas supply.
13 105442 OWNER’S MANUAL For more information, visit www.desatech.com AUTO OFF ON INST ALLA TION Continued Figure 21 - Routing Flexible Gas Line CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed • Phillips screwdriver • sealant (resistant to propane/LP gas, not provided) 1.
14 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com O POSI T P O Open Closed Equipment Shutoff Valve Figure 24 - Checking Gas Joints (Shown with O.
15 105442 OWNER’S MANUAL For more information, visit www.desatech.com WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
16 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com LIGHTING INSTRUCTIONS 1. STOP! Read the safety inf ormation, column 2. 2. Make sur e equipment shutoff valve is fully open. 3. Set switch in OFF position.
17 105442 OWNER’S MANUAL For more information, visit www.desatech.com OPERA TING HEA TER Continued TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. T urn contr ol knob clockwise to the OFF position. 2a . Set selector switch in the OFF position 2b .
18 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com OPERA TING HEA TER Continued Figure 37 - Correct Pilot Flame Pattern Pilot Burner Thermocouple Figure 38 - Incorrect Pilot Flame Pattern Check pilot flame pattern and burner flame patterns often.
19 105442 OWNER’S MANUAL For more information, visit www.desatech.com CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use.
20 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
21 105442 OWNER’S MANUAL For more information, visit www.desatech.com TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfirin.
22 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
23 105442 OWNER’S MANUAL For more information, visit www.desatech.com TECHNICAL SER VICE You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Techni- cal Service Department at 1-800-DESA LOG (1-800-337-2564).
24 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com ILLUSTRA TED PA R T S BREAKDOWN CF26PR O F F P I L O T O N H I L O O F F P I L O T O N H I L O.
25 105442 OWNER’S MANUAL For more information, visit www.desatech.com P ARTS LIST CF26PR This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual.
26 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com ILLUSTRA TED PA R T S BREAKDOWN CF26PR 5 8 15 17 13 14 11-2 11-1 19 4 12 16 10 6 5 9 1 2 18 7 .
27 105442 OWNER’S MANUAL For more information, visit www.desatech.com P ARTS LIST CF26PR KEY CF26PR NO. PART NO. DESCRIPTION QTY. 1 102633-02CK Outer Casing Top 1 2 102624-02 Outer Casing 1 3 099230-02 Shoulder Screw 12 4 105631-01CK Assy.
28 105442 VENT -FREE PROP ANE/LP BA Y FRONT FIREPLACE CF26PR For more information, visit www.desatech.com ACCESSORIES Purchase these fireplace accessories from your local dealer or Parts Central (see page 23). If they cannot supply these accessories call DESA International’s Sales Depart- ment at 1-800-458-2472 for referral infor- mation.
29 105442 OWNER’S MANUAL For more information, visit www.desatech.com NOTES _______________________________________________________________________________________________ __________________________.
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com INTERNA TIONAL 105442-01 REV. D 09/00 LIMITED WARRANTY VENT-FREE PROPANE/LP GAS HEARTH ‚ FIREPLACE DESA Internation.
デバイスDesa CF26PRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa CF26PRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa CF26PRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa CF26PRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa CF26PRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa CF26PRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa CF26PRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa CF26PRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa CF26PRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。