Quick Start Guide 00825-0200-4420, Rev FE August 2015 Emer son ™ Smar t Wireless Gate wa y 1420 00825-0200-4420_RevFE.fm Page 1 Monday, August 10 , 2015 3:25 AM.
August 2015 2 Quick Start Guide NO TICE This guide provides basic guide lines f or the Smart Wireless Gatewa y . It doe s not provide instructions for diagnostics, m ainte nanc e, se rv ice , or troubleshooting. R ef er t o the Smart Wireles s Gate way R ef ere nce Manu al (documen t number 00809-0200-4420) for more information and instructi ons.
Quick Start Guide 3 August 2015 Wireless c onsiderations Powe r u p s e q u en ce The Smart Wi reless Gateway (Gateway) shou ld be instal led and functi oning properly before power modules are installed in any wireless fi eld devices.
August 2015 4 Quick Start Guide General c onsiderations PC requirements Operating system (o ptional software onl y) Microsof t ® Windows ™ XP Profession al, Service Pack 3 Windows Ser ver 2.
Quick Start Guide 5 August 2015 Step 1: Initial connection and configuration DeltaV ™ ready If the Gateway was ordered Delta V Ready (Data Protocol s Code 5), then skip to St ep 2: Physical installation , and connect the Gateway to a Del taV 10.3 or newer control network.
August 2015 6 Quick Start Guide Note Figure 1 depicts the terminal block of legacy Gatewa ys prior to the introduction of PoE capabilities. Figure 2 shows the terminal block arrangeme nt of a PoE versio n of t he Gateway.
Quick Start Guide 7 August 2015 Note Only one port and one mode of opera tion (PD or PSE) can be selected at a time ; any othe r combin ation of jumpe rs is inv alid. Note IEEE 802.3af-2003 PoE standard pro vides up to 15.4 W o f DC powe r (minimum 44 V DC and 350 mA) to eac h device .
August 2015 8 Quick Start Guide c. Selec t Internet Protocol (T CP/IP) , th en s ele ct the Proper ties button. Note If the PC/laptop is from another ne twork, record the c urrent IP address and o ther se ttings so the PC/lap t op can be re turned to th e origin al n etwork afte r the G at ewa y ha s been con fig ured.
Quick Start Guide 9 August 2015 3. Disab le proxies. a. Ope n a standard w eb browse r (Inte rnet Explorer , Moz illa Firef ox, or oth er) . b. Nav igate to T ools>Intern et Options>Co nnec tions>LAN Settings . c. Uncheck the b ox under P r ox y Ser ver .
August 2015 10 Quick Start Guide Con figure the Smart Wireless G atewa y To complete init ial configura tion for the Gateway: 1. Acce ss the default web page f o r the Gatewa y at https :/ /192.168.1.10 . a. In the User n am e fi el d, enter admin . b.
Quick Start Guide 11 August 2015 St ep 2: Physical installation Pipe mount Tools needed: 2-in. (51 m m) mounting pi pe or ma st Tw o 5 / 16 -in. (7,9 mm) u-bo lts supplied with Gateway 1 / 2 -in . s oc ket -h ead w ren ch For installing the Gateway with a pipe mou nt: 1.
August 2015 12 Quick Start Guide R emote an te nna (optional) The remote antenna op tions provide flex ibility for mounting the Gateway based on wireless connect ivity, lightni ng protection, and current work practi ces. The remote mount ante nna kit includes coa xial sealant for the cable conne ctions for the lightning arrestor and antenna.
Quick Start Guide 13 August 2015 Figure 6. Installation of WL2/WN2 Option Installation of WL3/WL4 op tion (indoor to outdoor applications) 1. Mount the antenn a on a 1.5- to 2-in. pipe mast u si ng the supplied mounting equipme nt. 2. Mount the light ning arrestor near the building egress.
August 2015 14 Quick Start Guide Figure 7. Installation of WL3/WL4 O ption Note : Weather proofing is required! The remot e mount antenna kit includes c oaxial sealant for the cable connections for the lightning arrestor , antenna, and Ga teway . The coaxial se alant must be applied to guaran tee per formance o f the wireless fie ld net work.
Quick Start Guide 15 August 2015 Note The coaxial cables on the remo te antenna options WL3 and WL4 are interch angeable for installation c onvenie nce. T ab le 3. Remote Antenna Kit Options Kit option An tenna Cable 1 Cable 2 Lightning arrestor WL2 1 / 2 W avele ngth Dipole Omni- Directio nal +6 dB Gain 50-f t.
August 2015 16 Quick Start Guide Step 3: Connect to the h ost system 1. Wire the Gate way’s Ethe rnet 1 (Prim ar y) or Serial Output conne c tion to the Host System Ne t work or Serial I/O . 2. For serial connection s, connect A to A, B to B, making sure al l terminations are cle a n and secured t o avoid wiring c onnec tion problems .
Quick Start Guide 17 August 2015 Twisted shield ed pair cable is generally used to wire the seria l connection, and it is standard practi ce to ground the sh ield on the seri al host side leav ing the shield floating on the Gateway side. Insulate the shield to avoid g rounding iss ues.
August 2015 18 Quick Start Guide St ep 5: V erif y operations Operation is verifie d through the web interfac e by opening a web browser from any PC on t he host s ystem netw ork and en tering the Gateway IP address or DHCP host name in the address bar.
Quick Start Guide 19 August 2015 Produc t specifications Input pow er 10.5 – 30 VDC (must be a Cl ass 2 power supply) Curr en t d raw Operating curren t draw is based on 3.6 W average po wer consumption. Momentary startup c urrent draw up to twice operating curren t draw.
August 2015 20 Quick Start Guide Environment al Opera t ing te mperature range -40 to 140 °F (-40 t o 70 °C) Opera t ing humidit y range 10 – 90% relative h umidity Ph ysical specifications W eight 10 lb (4.
Quick Start Guide 21 August 2015 Ethernet 10/1000base- TXEthernet commun ication port Protocols: EtherNet/IP ™ Modbus TCP, OPC, HART-IP ™ , HTTPS (for Web Interface) Wiring: Cat 5Eshielded cable Wiring distance: 32 8-ft. (100 m) Modbus Supports Modbus RTU and Modbus TCP with 32-bi t floating point va lues, integers, and sc aled integers.
August 2015 22 Quick Start Guide Produc t Cer tifications Rev 1 .2 European Directive Inf ormation A cop y of the EC Decl aration of Conformity can be found at the end of the Quick Start Guide. The most rec ent revision o f the EC Declara tion of Conf ormit y can be found at www .
Quick Start Guide 23 August 2015 Can ada N6 Canad a Division 2 Certificate: CSA 70010780 Standar ds: C AN/CSA C22.2 No. 0-M91 (R2001), C AN/CSA Std C22.
August 2015 24 Quick Start Guide NF IECEx Dust Certificate : IECEx BAS 07.0013X Standar ds: IEC 60079-0: 2011, IEC 60079-31: 2008 Marking s: Ex tc IIIC T135 °C Dc, (-40 °C ≤ T a ≤ +65 °C) Special Condition for Safe Use (X): 1. The surface resistivit y of the ante nna is greater th an 1G Ω .
Quick Start Guide 25 August 2015 Figure 12. Smar t Wireless Gatewa y 1420 Declaration of Conformity 00825-0200-4420_RevFE.fm Page 25 Monday, August 1 0, 2015 3:25 AM.
August 2015 26 Quick Start Guide 00825-0200-4420_RevFE.fm Page 26 Monday, August 1 0, 2015 3:25 AM.
Quick Start Guide 27 August 2015 00825-0200-4420_RevFE.fm Page 27 Monday, August 1 0, 2015 3:25 AM.
Quick Start Guide 00825-0200-4420, Rev FE August 2015 Global Headquarters Emerson Process Management 6021 Innovation Blvd . Shakopee, MN 553 79, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RFQ.RMD-RCC@EmersonProcess.com North America Regional Offic e Emerson Process Management 8200 Market Blvd.
デバイスEmerson 1420の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Emerson 1420をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmerson 1420の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Emerson 1420の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Emerson 1420で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Emerson 1420を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmerson 1420の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Emerson 1420に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmerson 1420デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。