INSTALLATION & OPERATION MANUAL MODEL NUMBERS: 25-PDV 55-SHP22 55-TRP22 25-PDVE 55-SHP22E 55-TRP22E Thank you for purchasing this product from a fine line of heating equipment. We wish you many years of safe heating pleasure with your new heating appliance.
A letter from our Technical Support department : Thank you for purchasing this fine produ ct from England’s Stove Works! England's Stove Works was started, a nd is still owned by, a family that believes strongly in a "Do It Yoursel f" spirit – that’s one reason you found this product at your favorite “Do It Yourself” store.
BEFORE RE-STARTING YOUR UNIT Every time before pressing “ON” to start your unit – Be sure to remove all ashes (burnt or partially burnt) from your burn pot area! Wearing protective gloves and with the unit cool, remove the Wear Plate and dump the ashes, ensuring that the air holes are clear from debris.
IMPORTANT INFORMATION 1. Check local installation codes for your area. C all your Homeowner’s Insurance representative for inspection of your stove’s installation. 2. Read and comply with the instructions in this manual. 3. This unit should be tested (dry run) before load ing pellets for 20 minutes.
14. Do not allow paint, chemicals or construction dust on or near your unit. Do not allow liquid or ANY foreign materials on or inside your unit. Shut your unit down and cover it when painting, construction or similar activity is taking place.
Proper Impingement (Baffle) Plate Placement in Pellet Stove Firebox Occasionally in shipping, the impingement (baffle) plate may shift out of its proper position. If this is the case with your stove, follow these instructions to r eturn the plate to its proper position.
FLUE SYSTEM Caution: Follow the pipe manufacturer’s installation instructions and directions for pas sing through combustible walls and ceilings. Be sure to check local codes in your area. NOTE : See the installation drawing later in this manual ( Illustration 1 ).
Through the Ceiling When venting the stove through the ceiling, the pipe is connected the same as through the wall, except the clean out tee is always on the inside of the house, and a 3” adapter is ad ded before the clean-out tee.
Freestanding Pellet Installation Caution: Follow the pipe manufacturer’s installation instructions and directi ons for passin g throu g h combustible walls and ceilin g s. Check local codes in y our area. Illustration 1 Basement Installation should be performed by professional installer.
OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE WITH THE DOOR OPEN. If door is left open (approximately ) two minut es, unit will stop feeding and fire will go out. Do not burn trash (paper bags, etc.) in this unit. This stove has an induced draft system and is designed to operate continuously, as frequent shutdown is not required.
E-Codes “E-Codes,” or Error Codes, are codes that will appear in the Heat Range and Blower Speed windows of the Control Board if your unit experiences problems. If you receive any of these codes, first attempt to reset your unit by pressing the “ON” button (only once).
DAILY OPERATION Refueling the Unit Always press the “OFF” touch pad before refueling. This stove has a (approximately) 60-lb. hopper, and should be refilled when the hopper level drops to three or four inches. Note : The hopper lid will be warm; therefore, you should always use some type of hand protection.
NOTE: The instructions belo w concerning the cl eaning of the burn pot and wea r plate area are especially important to the function of your stove. Failure to follow them regularly can re sult in burn-back and can damag e your uni t and/or void your warranty.
Monthly Ash Removal The large baffle plate (12-5/8” x 9-3/8”) that rests above and behind the burn pot (refer to the section on “Proper Impingement Plate Placement” and the exploded diagram in t he rear of this manual – Illustration 6 ) should be removed monthly.
MAINTENANCE CAUTION: UNPLUG THE UNIT PRIOR TO ANY SERVICE WOR K! SEE EXPLODED DIA GRAM ( ILLUSTRATION 6 ) FOR PARTS REFERENCE Parts Orders: (800) 516-3636 www.englanderstoves.com Questions: (800) 245-6489 NOTE: Visit our web site for downloadable maintenance sheets and/or a service video that details and illustrates the following maintenance tasks.
Convection Blower The Convection (room air) Blower (Part # PU-4C447 ) is located on the left side of the unit and can be removed by disconnecting the power leads and removing the four mounting screws. Once this is done, the blower will slide out of the stove.
Control Board The Control Board (Part #PU-CB04) is a digital read-out board. This board offers a wide variety of settings to operate the unit. This part can be removed from the unit by loosening the two outside screws and pulling the board back to the inside of the stove.
Illustration 4 PU-CB04 Control Bo ard Diagr am (Wir ing) CAUTION: Moving Parts May Cause Injury. Do NOT Operate with Panel(s) Off. DANGER: Parts May Be Hot. Risk of Electric Shock. Disconnect Power Before Servicing Unit. Notes on termination of Pellet Vent Pipe (see also “FLUE SYSTEM” sectio n of manual) : 1.
Adjusting your Hopper Lid Latches The seals around the top of the pellet hopper are important to safe an efficient operation of the unit. The latches installed on these units are designed to pull the hopper lid tight against this seal.
ACCESSORY ITEMS The following accessories can be added to your unit at anytime after purchase; however, let the unit cool down before adding any accessories. Thermostats WALL: An external wall thermostat (such as our Part # G U-1E30-914 ) can be used on our pellet units as long as it is a low-voltage that wor ks with millivolt systems.
REPLACEMENT PARTS, ACCESSORIES AND OPTIONS AC-GGK Glass Gasket Kit (gasket only, no glass) AC-DGKC Door Gasket Kit (#2 on diagram) AC-114 Brass Louvers (#26 on diagram) (2001 and later Models; for ear.
Dimensions of your pellet unit: 28 ½”W x 30”H x 28 ½”D 375 lbs. (Approx. 13 ½” height from floor to center of exhaust) Illustration 6 Pellet Stove – Exploded View Diagram 22.
TROUBLE-SHOOTING GUIDE WARNING: TO AVOID EL ECTRICAL SHOCK ALWAYS DISCON NECT THE UNIT FROM THE POWER SOURCE BEFORE ATT EMPTING ANY REPAIR. IF THIS GUIDE DOES NOT CORRECT THE PROBLEM CALL YOUR LOCAL DEAL ER OR O UR TECHNICAL SUPPORT AT 1-800-245-6489.
Have this information on hand if you phone the factory or your dealer regarding this product. Retain for your files: Model Number __________________________ Date of Purchase ________________________ D.
WARRANTY REGISTRATION for England’s Stove Works Purchased by (Name) ______________________________________________ Address _________________________________________________________ City ____________.
デバイスEngland's Stove Works PELLET STOVESの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
England's Stove Works PELLET STOVESをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEngland's Stove Works PELLET STOVESの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。England's Stove Works PELLET STOVESの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。England's Stove Works PELLET STOVESで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
England's Stove Works PELLET STOVESを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEngland's Stove Works PELLET STOVESの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、England's Stove Works PELLET STOVESに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEngland's Stove Works PELLET STOVESデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。