Description The A1301 and A1302 are continuous-time, ratiometric, linear Hall-effect sensors. They are optimized to accurately provide a voltage output that is proportional to an applied magnetic field. These devices have a quiescent output voltage that is 50% of the supply voltage.
Continuous-T ime Ratiometric Linear Hall Ef fect Sensors A1301 and A1302 2 Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com Selection Guide Part Number Pb-free 1 Packing 2 Package Ambient, T A Sensitivity (T ypical) A1301ELHL T -T Y es 7-in.
Continuous-T ime Ratiometric Linear Hall Ef fect Sensors A1301 and A1302 3 Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.
Continuous-T ime Ratiometric Linear Hall Ef fect Sensors A1301 and A1302 4 Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com Characteristic Definitions Quiescent Output V oltage.
Continuous-T ime Ratiometric Linear Hall Ef fect Sensors A1301 and A1302 5 Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com T ypical Characteristics (30 pieces, 3 fabrication lots) Continued on the next page.
Continuous-T ime Ratiometric Linear Hall Ef fect Sensors A1301 and A1302 6 Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com T ypical Characteristics, continued (30 pieces, 3 fabrication lots) 1301 De v ice V OUTQ v s.
Continuous-T ime Ratiometric Linear Hall Ef fect Sensors A1301 and A1302 7 Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com Package LH, 3-Pin; (SOT -23W) 0.15 0.00 .006 .
Continuous-T ime Ratiometric Linear Hall Ef fect Sensors A1301 and A1302 8 Allegro MicroSystems, Inc. 115 Northeast Cutoff, Box 15036 Worcester, Massachusetts 01615-0036 (508) 853-5000 www.allegromicro.com The pr oducts described herein ar e manufactured under one or mor e of the following U.
デバイスAllegro MicroSystems A1301の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Allegro MicroSystems A1301をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAllegro MicroSystems A1301の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Allegro MicroSystems A1301の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Allegro MicroSystems A1301で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Allegro MicroSystems A1301を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAllegro MicroSystems A1301の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Allegro MicroSystems A1301に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAllegro MicroSystems A1301デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。