EnviroメーカーKodiak 1200 Fireplace Freestandingの使用説明書/サービス説明書
ページ先へ移動 of 50
SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER. BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE.
T able of Contents 2 Safety Precautions.............................................................................................3 Operating Instructions........................................................................................4 Building Y our Fire.
3 Safety Prec autions FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIR O” W OOD ST O VE, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: ● Please read this entire manual before you install and use your new woodstove. Failure to follow instructions may result in property damage, bodily injury or even death.
Oper a ting Instructions FIRST START When rst installed, the chimney , rebricks and steel are cold and it usually takes several hours on a fairly high burn f or them to become hot and dry enough f or the sto ve to function well.
REPLACING THE GLASS: Never strike or slam the door , hit the glass or let burning wood rest against it. If the glass cracks when the re is burning, do not open the door until the r e is out and do not oper ate the stove again until the glass has been replaced.
6 Oper a ting Instructions MAINTENANCE: At the end of each heating season clean the chimney and the smoke pipe. If soot has accumulated above the top bafe bricks, remove, clean, and then replace them. If the secondary air tube is badly eroded, replace it.
7 Oper a ting Instructions c) DO NOT OVERFIRE . If the heater or chimney connector glows, you are ov erring. d) CAUTION: DO NOT PLACE FUEL WITHIN SPACE HEA TER INST ALLA TION CLEARANCES OR WITHIN THE SP ACE REQUIRED FOR CHARGING AND ASH REMOV AL. 4.
8 Oper a ting Instructions length f or the logs used in the 1200 would be about 16“ (381 mm) but it can burn pieces up to 18” long. Ideal length for the logs used in the 1700 would be about 18“ (381 mm) but it can burn pieces up to 20” long logs.
9 Oper a ting Instructions a) Air supply – Inside the home, normal household appliances such as clothes dryers and forced-air furnaces compete for air , resulting in air starvation to the re. This creates a condition in the house known as negative pressure.
Oper a ting Instructions H OW I T W ORKS : 1 / 2 " Ceramic baffle; reflects heat down to burn up smoke. Secondary air tubes; creates a secondary burn on the particles in the smoke. Intake air . Smoke Intake air . Dry seasoned wood Primary air; window airwash.
11 Specific a tions 1200 S PECIFICATIONS : Model 1200 Freestanding 1200 Insert Flat T op Step T op Width x Depth 25” x 22 7 / 16 ” (635 mm x 570 mm) 27” x 21” (705 mm x 546 mm) Height wi.
Specific a tions 1700 S PECIFICATIONS : Model 1700 Freestanding 1700 Insert Flat T op Step T op Width x Depth 25” x 26 15 / 16 ” (635 mm x 684 mm) 27” x 26” (705 mm x 660 mm) Height with pe.
13 Specific a tions C LEARANCES T O C OMBUSTIBLES - 1200 I NSERT : A Minimum clearance to an unshielded side w all 10” (254 mm) B Minimum clearance to an unshielded 8” (203 mm) mantle 21” (533 m.
Specific a tions C LEARANCES T O C OMBUSTIBLES - 1200 F REESTANDING : MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES* Single W all Pipe Double W all Pipe** Double W all Pipe with Heat Efciency Shield 50-1088 (Flat top model only) T op vent out back wall with min.
15 Specific a tions C LEARANCES T O C OMBUSTIBLES - 1700 F REESTANDING : MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES* Single W all Pipe Double W all Pipe** Double W all Pipe with Heat Efciency Shield 50-1088 (Flat top model only) T op vent out back wall with min.
Specific a tions D IMENSIONS - 1200 I NSERT : 3 / 16 " (5mm) 18 3 / 8 " (467mm) Regular Surround 27 15 / 16 " (709mm) Oversized Surround 33 3 / 16 " (709mm) 19 1 / 8 " (486mm).
17 Specific a tions D IMENSIONS - 1200 I NSERT : 33 7 / 8 " (860mm) 46 1 / 8 " (1 171mm) 27 3 / 4 " (705mm) 3 / 16 " (5mm) 18 3 / 8 " (467mm) Regular Surround 27 15 / 16 " (709mm) Oversized Surround 33 3 / 16 " (709mm) 19 1 / 8 " (486mm) 21" (533mm) Min.
Specific a tions D IMENSIONS - 1200 F REESTANDING : 25" (635mm) 6 1 / 16 " (153mm) 9 15 / 16 " (252mm) 28 1 / 4 " (718mm) 29 15 / 16 " (760mm) 30 1 / 4 " (769mm) 10".
19 Specific a tions D IMENSIONS - 1700 F REESTANDING : 26 15 / 16 " (684mm) 9 15 / 16 " (252mm) 15 7 / 8 " (403mm) 25" (635mm) 19 3 / 8 " (492mm) 6 1 / 16 " (153mm) 25 15.
Specific a tions F REESTANDING S IDE D IMENSIONS F OR F AN K IT : .
21 Inst alla tion Please read and understand these instructions before instal ling pedestal or ash pan and leg option. F ailure to follow these instructions carefully could cause personal injury or property damage. All screws are pre-installed on the base of the unit.
• Place the unit on the pallet on its back. • Attach pedestal spacer to bottom of the unit, using the supplied screws. • Attach the air channel box to the front of the pedestal spacer using two (2) T -20 screws. • Slide the ash pan assembly over the bolts, using the key -holed slots provided, and tighten all f our (4) bolts.
23 Inst alla tion O UTSIDE A IR K IT : It is mandatory to use outside air for installations in mobile homes. A 4” (10.2 cm) fresh air adaptor ki t is av ailable. This adaptor can be installed either on the back pedestal or through the oor under the pedestal.
Inst alla tion C HIMNEY I NSTALLATION T HROUGH W ALL : Here are four (4) methods of combustible w all chimney connector pass-throughs. Information w as provided from NFP A 211. Method A . 12” (304.8 mm) Clearance to Combustible W all Member: Using a minimum thickness 3.
25 Inst alla tion I NSTALLATION OF A L ISTED , F ACTORY B UILT C HIMNEY - F REESTANDING : This is a generic set of instructions; always follow the chimney manufacturer’s instructions explicitly. Also refer to “ R ECOMMENDED H EIGHTS F OR F LUE P IPE ” .
Inst alla tion Hearthpad Floor Pedestal Woodstove Optional fan Outside air connection through wall or floor Chimney connector Ceiling Insulated chimney Roof flashing Roof Roof radiation shield (if required) Minimum air space in accordance with chimney manufacturer .
27 Inst alla tion M ASONRY C HIMNEY I NSTALLATION - F REESTANDING : DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. A non-combustible oor protector is required under all freestanding units; refer to “ C LEARANCES T O C OMBUSTIBLES - 1200 F REESTANDING ” or “ C LEAR ANCES T O C OMBUSTIBLES - 1700 F REESTANDING ” .
Figure 29: Freestanding Installation into existing replace. Unless you are experienced, we recommend installation by your dealer or a professional installer. Many venting manufacturers have listed kits av ailable to connect a stove to a masonry replace.
29 At least 3 feet (914 mm) Hearthpad Floor Pedestal Woodstove Optional fan Outside air connection through wall or floor Double wall pipe Ceiling support Ceiling Spark arrestor cap Roof flashing Roof Radiation Shield Insulated chimney Bolt stove to floor Figure 30: Freestanding installation into mobile home.
Inst alla tion M ASONRY F IREPLACE I NSTALLATION - I NSERT : Unless you are experienced, we recommend installation by your dealer or a professional installer. It is recommended that you install the decorative plates (if purchased) into the shrouds before installing the unit.
The ue collar is remov able for installations into replaces with low openings . a) Remo ve the rst two (2) front secondary air tube and ceramic bafes, if installed (see C ERAMIC B AFFLE I NSTALLATION ) . b) Unscrew the nut on top of the inside of the rebox, using a 9 / 16 ” wrench or socket (see Figure 34).
32 Inst alla tion Figure 35: Attaching removable ue. Figure 36: Leveling leg. S URROUND P ANEL S EALED I NSTALLATION F OR USA O NLY - I NSERT : Before starting this type of installation refer to I NSTALLATION - M ASONRY F IREPLACE I NSTALLATION - I NSERT for additional information.
33 Inst alla tion I NSTALLATION U SING A B LOCK -O FF P LATE F OR USA O NLY - I NSERT : If this unit is to be instal led into a masonry replace or a zero-clear ance replace with a direct connection you must install a non-combustible seal-off device such as a block -off plate or damper adapter .
34 Inst alla tion 5. Mount the block -off plate using masonry screws in a masonry replace and sheet metal screws on a zero- clearance replace (screws need only be long enough to penetrate the rst layer of metal). 6. Insulate the block -off plate using high-temperature berglass insulation and furnace cement.
Inst alla tion M ODEL 1200 B RICK P LACEMENT & T UBE L OCATIONS : COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS. When replacing bricks, use only pumas type re bricks. TOTAL BRICKS: 11 - Full size bricks 9” long x 4.
Inst alla tion M ODEL 1700 B RICK P LACEMENT & T UBE L OCATIONS : COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS. When replacing bricks, use only pumas type re bricks. TOTAL BRICKS: 15 - Full size bricks 9” long x 4.
37 Inst alla tion D OOR I NSTALLATION : Please inspect all components f or damage. If damage has occurred, please contact the courier compan y , dealer , or distributor and hav e components repaired or replaced before installation. R emove the door from the packaging.
C ERAMIC B AFFLE I NSTALLATION : 1. Remov e the front secondary air tube by placing a screwdriver (any style except at head) into one of Left Ceramic Baffle Right Ceramic Baffle Figure 47: Installation of Ceramic Bafe.
39 The f an kit is pr e-installed into the left shroud that comes with your unit. If a decorative set of shroud plates is purchased, the fan assembly must be removed from the shroud to installed the decor ative plates (refer to “ R EMOV AL O F T HE S HROUDS - I NSERT ”) .
Figure 52: Changing decorative plate. Inst alla tion R EMOVAL O F T HE S HROUDS - I NSERT : A B B 1. If the surround panel is installed, remove i t by lifting the panel str aight up then out. 2. For the right shroud, twist the handle on the air control clockwise to remove it f rom the rod.
41 Inst alla tion I NSTALLATION O F T HE S URROUND P ANEL - I NSERT : Figure 55: Screw to hold the trim against the sur- round. Figure 53: Corner brackets for trim.
P ar ts List Ref erance Number Description P art Number 1 120°F (49°C) Ceramic F an T emperature Sensor EC -001 2 Domestic power cord - 115V EC -042 Convection Blower - 115V (Freestanding) EC -069 3 F an Controller with Knob - 115V EF-045 4 Door Gasket - 7 feet (2.
43 P ar ts List Ref erance Number Description P art Number 26 Door Handle Assembly (Rod, Cast Latch, Br ass Spring) 50-1121 27 W ood Door Glass R etainer Kit (With Screws) 50-1122 28 1200 Freestanding.
P ar ts Diagr am - F reest anding 31 30 34 35 29 28 33 32 15 17 19 18 46 25 44 4 27 7 9 26 14 2 1 6 17 21 20 23 22 24 43 45 8 16 Kodiak - Freestanding Components October 2004 44.
45 P ar ts Diagr am - Pedest als & L egs 1 1 13 10 12 41 39 40 5 38 36 37 Kodiak - Pedestal and Leg Kit Components May 2006.
P ar ts Diagr am - F ireplace Inser t 49 15 53 54 47 8 50 48 51 52 54 42 2 3 Kodiak - Fireplace Insert Components October 2004 Common parts are shown in Parts Diagram - Freestanding.
47 W arr anty Sherwood Industries Ltd. Limited Lifetime Warranty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood industries, our commitment to the highest level of quality and customer service is the most important thing we do.
W arr anty 6. If the problem is not covered by the Limited W arrant y , the customer wil l be responsible for all repair costs, as well as all storage, shipping and the cost of remo ving and re-installing the stove. 7 . If you are not satised with the service provided by the Enviro dealer , write to Sherwood Industries Ltd.
49 d) Salt air in coastal areas or high-humidity can be corrosive to the nish; these environments can cause rusting. Damage caused by salt air or high humidity is not cov ered by the Limited W arranty .
50 Inst alla tion Da t a Sheet The following information must be recorded by the installer f or warr anty purposes and f uture ref erence. NAME OF OWNER: _________________________________________ ADDR.
デバイスEnviro Kodiak 1200 Fireplace Freestandingの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enviro Kodiak 1200 Fireplace Freestandingをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnviro Kodiak 1200 Fireplace Freestandingの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enviro Kodiak 1200 Fireplace Freestandingの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enviro Kodiak 1200 Fireplace Freestandingで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enviro Kodiak 1200 Fireplace Freestandingを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnviro Kodiak 1200 Fireplace Freestandingの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enviro Kodiak 1200 Fireplace Freestandingに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnviro Kodiak 1200 Fireplace Freestandingデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。