rletech.com 2 970.484.6510 Copyright Notice ©2010 RLE T echnologies. All right s reserved. No par t of this publication may be reproduced or distributed in any form or by any means, or st ored in a dat abase or retrieva l system, without the prior written permission of RLE T echnologies.
970.484.6510 3 r letech.com Product Registration Product registration help s RLE T echnologies inform owners of: • Product upgrade s • Firmware enhance ments • New product s and technologie s • S pecial offers available only to registered users Access and submit Product Registr ation info rmation from the F1 10 Configuration M enu.
rletech.com 4 970.484.6510 Notes:.
Content s rletech.com 5 970.484.6510 1 System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
970.484.6510 6 r letech.com Notes:.
Figures rletech.com 7 970.484.6510 1 System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Figure 1.1 F110 Font Panel Indicators and Con trols . . . . . . . . . . . . . . . . . . . . . . . .
rletech.com 8 970.484.6510 Notes:.
T ables rletech.com 9 970.484.6510 B Modbus Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Table B.1 Read Output Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
970.484.6510 10 rletech.com Notes:.
www.rletech.com 11 970.484.6510 C HAPTER C HAPTER 0 S YSTEM O VERVIEW 1.1. Product Description The F110 Monitoring System is a comprehensiv e system which provides equipment protection by monitoring critical operating parameters in enterprises, remo te network facilities, communication rooms, and critical support syst ems.
www.rletech.com 12 970.484.6510 1 System Overview 1.2. Front Panel Indicators and Controls Figure 1.1 F110 Font Panel Indica tors and Controls Power LED – Green (On) if power is on. Network Link – Green (On) if a network con nection is found. Network Activity LED – Green (On) if network communication is o ccurring.
www.rletech.com 13 970.484.6510 1 System Overview 1.3. T erminal Block Designations Figure 1.2 F110 Terminal Block Designations Rear Panel Switch Sensor Port 1 Digital Input 1 Switch Sensor Port 2 Dig.
www.rletech.com 14 970.484.6510 1 System Overview Notes:.
www.rletech.com 15 970.484.6510 C HAPTER C HAPTER 0 G ETTING S T ARTED 2.1. Inst allation The F110 comes in a 4.5”W x 1.25”H x 2.5”D desktop enclosure. M ount or place the unit in the desired location. A 19 in ch (.48m) rack mount enclosure is available from RLE.
www.rletech.com 16 970.484.6510 2 Getting Started 2.2.1 Search Select the Search button to scan the network for the F1 10 hardware devices. If an F110 is physically attached to your network anywhere it will be located in this scan.
www.rletech.com 17 970.484.6510 2 Getting Started 2.2.6 Up date Click the Update button to update the firmware inst alled on the selected F110. Updated firmware files provided by RLE, add new fe atures and enhance the web browser interface. These firmware updates are available from RLE if firmware replace ment is necessary.
www.rletech.com 18 970.484.6510 2 Getting Started 2.3.2 RJ45 Ethernet Connection The F110 has an interna l 10/100BaseT Ethernet port use d to configure and monitor th e F110. The Ethernet port supports Web browser access, email (SMTP), Modbus, and SNMP.
www.rletech.com 19 970.484.6510 C HAPTER C HAPTER 0 F1 10 W EB I NTERFACE 3.1. F1 10 Web Interface Overview The F110’s Web interface provides a convenie nt way to check the F110’s st atus and reconfigure basic settings from any internet enab led computer.
www.rletech.com 20 970.484.6510 3 F110 Web Interface color based upon where the temperature or humid ity is in relation to th e established h igh and low thresholds. If the temperature or humidity is between the hi gh and low thresholds an d more than five (5) degrees from either threshol d, the status icon will be green .
www.rletech.com 21 970.484.6510 3 F110 Web Interface Note There is no user name o r no password from RLE. Passwor d can be assigned to the unit later in the configuration menu. Ther e is no user name that can be configured at this time. 3.3.1 Network The Network tab stores settings to control how the F110 appears on the local network.
www.rletech.com 22 970.484.6510 3 F110 Web Interface 3.3.2 Email The Email tab stores settings for the F110 to send Email Alert Notifications when alert thresholds are exceeded.
www.rletech.com 23 970.484.6510 3 F110 Web Interface Note Many email servers block SMTP email by default. To use SMTP email with the F110, be sure the F110 IP address is added to the list of allowed SMTP relay hosts on the email server you are using for email.
www.rletech.com 24 970.484.6510 3 F110 Web Interface 3.3.4 Channel 2, Channel 3 and Channel 4 The Channel 2, Chann el 3 and Channel 4 tabs ar e used to configure sensor labels and to set temperature thresholds, temperature/humidity th resholds and/or alarm states for the sensors connected to sensor channe ls 2, 3 and 4 on the front of the F110.
www.rletech.com 25 970.484.6510 3 F110 Web Interface Figure 3.6 Sensor Settings 3.3.5 Switched Sensor Alarm Configuration The Channel 1 tab is used to co nfigure sensor la bels and alarm states (normally open or closed) for the eight (8) switch sensor ports (dry contact inputs) on the back of the F110 unit.
www.rletech.com 26 970.484.6510 3 F110 Web Interface Figure 3.7 Security Settings 3.3.7 Advanced The Advance d tab is used to configure the Temperature Scale Configuration , Time & Date Configuration by connecting to a NTP server and provides a Trace Configuration for diagnostics when communicatin g to other equipment.
www.rletech.com 27 970.484.6510 3 F110 Web Interface Temperature Scale Conversion : You can select how the F110 displays the Temperature output on the Status page, eith er being Fahrenheit or Celsius .
www.rletech.com 28 970.484.6510 3 F110 Web Interface 3.3.9 Help Screen The Help screen displays the current firmware on the F110 unit. There are hyperlinks available for contacting RLE Technolog ies, RLE Technical Support, and Web Site link fo r viewing other RLE products and information.
www.rletech.com 29 970.484.6510 A PPENDIX C HAPTER 0 M ODBUS C ONFIGURATION V IA T ELNET A.1. F1 10 Modbus Cap abilities By default, the F110 is enabled to listen on TCP port 502 for Modbus requests.
www.rletech.com 30 970.484.6510 A Modbus Configuration Via Telnet Enable MODBUS? (N)? Enter Y to enable Mod bus and N to disable it. When Modbus i s disabled, the F110 will not actively listen on the Modbus TCP port for Modbus requests. MODBUS Port: (502) By default, the F110 listens fo r Modbus requests on TCP port 502.
www.rletech.com 31 970.484.6510 A PPENDIX C H APTER 0 M ODBUS R EGISTERS Table B.1 Read Output Registers Register Name Description Units Range 40002 FC Family Code (8 Switch Sensors) None 0-65535 4000.
www.rletech.com 32 970.484.6510 B Modbus Registers 40026 TL Low Tempera ture (External Sensor 3) Celsius x100 0-65535 40027 HC Current Humidity (Exter nal Sensor 3) % Relative Humidity 0-65535 40028 H.
www.rletech.com 33 970.484.6510 B Modbus Registers 07 Switch Sensor 8 Status; 1 = On, 0 = Off 08-15 Spare Table B.4 Status Flags (Reg ister 40004: SC) Bit Status Flag 00 Switch Senso r 1 Alarm O n: 1 .
www.rletech.com 34 970.484.6510 B Modbus Registers Notes:.
www.rletech.com 35 970.484.6510 A PPENDIX C HAPTER 0 T ECHNICAL S PECIFICATIONS Table C.1 Technical Specifications Power 5VDC @ 800mA max.; wa ll adaptor included Wall Adapter Input 110/240VAC 50/60Hz.
www.rletech.com 36 970.484.6510 C Technical Specifications Operating Environment Temperature -40°F to 185° F (-40°C to 85°C) Humidity 5% to 85% RH, no n-condensing Altitud e 15,000ft (4,572m ) max. Storage Environment -40°F to 185°F (-4 0°C to 85° C) Dimensions Box Enclosure 4.
デバイスFalcon MONITORING F110の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Falcon MONITORING F110をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFalcon MONITORING F110の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Falcon MONITORING F110の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Falcon MONITORING F110で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Falcon MONITORING F110を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFalcon MONITORING F110の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Falcon MONITORING F110に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFalcon MONITORING F110デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。