69-Field 0412 Heat Reco very V entilators Operation and Installation Manual This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. It meets ENERGY STAR requirements only when used in Canada.
Getting to Know your Heat and Energy Recovery Ventilator Ventilation and Control Options How the Dehumidistat Works (Colder Climates) Glossary and Additional Information Warranty ........................................................................
3 Thank you for purchasing a Field Control Heat/Energy Recovery Ventilator (HRV/ERV). The HRV/ERV provides fresh air to your home while recovering energy from the air it exhausts. There are numerous benefits to a properly installed, operated, and maintained HRV/ERV: • Exhausts the stale, contaminated air, found in today’s tight buildings.
Your HRV/ERV system produces a dehumidifying effect when outdoor humidity levels are lower than indoor humidity levels. These conditions occur normally when outdoor termperatures are below 60°F. An additional dehumidification effect is achievable with the Optional Dehumidistat (Part DH1).
The Dehumidistat Ventilation Control offers ON/OFF, High Speed/Low speed plus an electronic dehumidistat. Key Features • 2 Speed Fan setting (Low/High) • Electronic Dehumidistat • Instruction Card is inserted in the control • Slim-line design • Connect to 3 wire 20 gauge low voltage wire.
The timer w ill override th e Operational Mo de (regardles s of the setting) and initiate high speed ventilation. Upon completion of the timer cycle, the HRV/ERV returns to your selected Operational Mode and speed setting. Lifestyle 20/40/60 Minute Timer Initiates high speed ventilation for 20, 40 or 60 minutes.
1. Inspect Exterior Hoods at least once a month. Make sure exhaust and fresh air supply hoods are not blocked or restricted by leaves, grass, or snow. In winter, it is especially important to make sure snow is not blocking the hoods or that frost has not built up on the wire mesh (bird screen).
THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for cleaning or service. MOTORS AND BLOWERS Each air stream has one centrifugal blower driven by a common PSC motor.
Port Configuration and Airflow Model FC95HRV In order to make the HRV as space efficient as possible, the INDOOR supply and return ports are converted from round to oval shape.
THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for cleaning or service. MOTORS AND BLOWERS Each air stream has one centrifugal blower driven by a common PSC motor.
DIMENSIONS FC200HRV inches (mm) Model FC200HR V All units conform to CSA and UL standards. THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for cleaning or service.
12 ST ALE AIR TO OUTSIDE FRESH AIR FROM OUTSIDE ST ALE AIR FROM INSIDE FRESH AIR TO INSIDE 14 3 / 4 " (375) 19" (483) * All Duc t Connection s 6"(150mm) FIL TERS BLOWERS *N OTE: F ron t clearance o f 25 inche s (63 5 mm) i s recommended for servicin g unit .
13 The Three Methods of Installation The following three installation methods are for the HRV/ERV system: • The Simplified installation. • The Partially Dedicated Installation • The Fully Dedica.
DIRECT CONNECTION of both the HR V SUPPL Y AIR STREAM and EXHA UST AIR STREAM to the FURNACE COLD AIR RETURN Installation Notes • Unit is normally balanced on HIGH speed with the furnace blower ON. • A minimum separation of 40 inches (1m) is recommended between the two direct connections.
DIRECT CONNECTION of the SUPPL Y AIR STREAM to the FURNA CE COLD AIR RETURN (Stale air drawn fr om key areas of home) Forced Air Furnace Outdoors EXHA UST AIR from various parts of home. i.e. bathrooms (if required), kitchens (if required). Cool Air Return Return Air 3' min.
Outdoors Installation Notes • Unit is normally balanced on HIGH speed with the furnace blower ON. • W eatherhood arrangement is for drawing purposes only . Six feet (2m) minimum separation is recommended. The W eatherhood must also be 18" (460mm) above grade minimum.
Installation STEP 4. Level the unit from left to right and front to back. - Adjust the unit down by lifting up on the buckle. - Adjust the unit up by pulling down vertically on the Hand Loops while lifting up the bottom of the cabinet. Location Install the unit in a heated space that provides convenient space for service access.
Drain Connection (HRV only) Grilles Drain Connection The HRV may produce some condensation during a defrost cycle. This water should flow into a nearby drain, or be taken away by a condensate pump. The HRV cabinet has prepunched holes for the drain (see below).
19 Weatherhood Installation Installing the Ducting from the Weatherhoods to the HRV/ERV The inner and outer liners of the flexible insulated duct must be clamped to the sleeve of the weatherhoods (as close to the outside as possible) and the appropriate port on the HRV/ERV.
20 Installation of the Dehumidistat or Dehumidistat Ventilation Control Standard Series Controls may be installed onto a flush mounted 2" x 4" electrical switch box or it may be surface mounted onto a wall.
21 Installation and Operation of 20/40/60 Minute Timer Operating your 20/40/60 Minute Timer Press and release the Select Button to activate high speed override. The High Speed Status Light will illuminate and the unit will run on high speed ventilation for 20 minutes.
22 Installation of the Healthy Home System™ Control (HHSC) Choose a Location The HHSC controller can be installed anywhere in your home. To simplify the installation, locate the HHSC control near the HVAC system and/or the HRV/ERV, since the HHSC does not require routine adjustment or occupant interaction.
23 Installation of the Healthy Home System™ Control (HHSC) 1 2 3 4 5 6 7 8 9 10 L O ON R Y G HI C NO NC BK F ACT ORY -INST ALLED JUMPER DO NO T REMOVE LO HI 24C * R C Wt Gt Gf V HHSC CONTROL RC W Y G RYW G THERMOST A T FURNA CE OR HEA T PUMP HR V/ER V WIRING TERMINALS 12V/24 V AC Field wiring, 20 A WG min.
24 Installation of the HHSC with the DH1 and 20/40/60 Minute Timers (test a) 1 2 3 4 5 6 7 8 9 10 L O ON R Y G HI C NO NC BK F ACT OR Y-INST ALLED JUMPER DO NO T REMO VE LO HI 24C * R C Wt Gt Gf V HHSC CONTROL RC W Y GR Y W G THERMOST A T FURNA CE OR HEA T PUMP HR V/ERV WIRING TERMINALS 12V/24 V AC Field wiring, 20 AWG min.
25 Installation of the DHVC Ventilation Control with 20/40/60 Minute Timers (test c) 1 2 3 4 5 6 7 8 9 10 L O ON R Y G HI C NO NC BK F ACT OR Y-INST ALLED JUMPER FOR ST ANDBY-OFF OPERA TION.
26 Interlocking the HRV/ERV to an Air Handler/Furnace Blower Connecting the HRV/ERV as illustrated will ensure the Air Handler/Furnace Blower Motor is operating whenever the HRV/ERV is ventilating.
27 • A positive or negative pressure may occur in the house • HRV/ERV may not operate at its maximum efficiency • The unit may not defrost properly Air Flow Measuring Gauges The magnehelic gauge and the digital manometer are suitable instruments for the balancing of air flows.
28 Balancing the Air Flows with a Pitot T ube STEP 1. D rill a 3/16” hole in the duct (ideally 3 f eet downstream of a ny elbows or bends and 1 f oot upstream of any elbows or bends) in the F resh Air and Stale air streams.
29 Air Flow Balancing using the Door Ports FC155HRV & FC200HRV only Door balancing ports (not on all models) are designed to be used in conjunction with a Magnehelic Gauge or Digital Manometer to measure the Stale and Fresh airflows for balancing.
30 Push and turn with slotted screwdriver. Damper automatically locks when pressure is released. Observe the location of the screws when connecting ductwork to the collar. Screws should be located no further than 1/2” from the outside edge of the collar and they should be no longer than 3/4”.
31 SYMPT OM CA USE SOLUTION Poor Air Flows Supply air feels cold Dehumidistat is not Operating Humidity Levels are too High Condensation is appearing on the windows Humidity Levels are too Low HRV and.
32 LEA VE FOR HOMEO WNER TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION Installing Contractor _________________________________________Telephone / Contact _____________________ Serial Number _______.
デバイスField Controls FC95HRV.の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Field Controls FC95HRV.をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはField Controls FC95HRV.の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Field Controls FC95HRV.の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Field Controls FC95HRV.で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Field Controls FC95HRV.を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はField Controls FC95HRV.の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Field Controls FC95HRV.に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちField Controls FC95HRV.デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。