® 80T -IR/E Extended Range Infrared Temperature Probe Instr ucti on Sheet Int roduct ion The Fluke 80T-IR/ E Extended Range Inf rared Temperature Probe (t he probe) is a nonc ontact temperature m eas urement acces s ory for us e with a t es t instrum ent capable of meas uring DC volts in the millivolt range such as a digital multimeter (DMM).
Safety I nfo rm ati on The 80T-IR/E c omplies with IEC Publ ication 1010-1- 1990 including A mendment 1, CSA C22.2 No. 231, ANSI/ I SA-S82.01 and .03 S af ety Standards . W WARNING IF TARGET EMMISSIVITY IS LESS T HAN 0.95, THE PROBE CAN I NDICATE A TEM PERATURE LOWER THAN THE ACT UAL TARGET TEM PERATURE.
Compa tibilit y The probe is compatible wit h all DC millivolt measuring instrum ents that have a m inimum of 1 M W input impedance and accept s afety shrouded, standard diameter 0. 16 i n. (4 m m ) banana pl ugs . Operati on To take a meas urement, perform t he f ollowing steps : 1.
300mV V V OFF 0 1 02 03 0 300mV V V OFF A A ! 1000V 750V FUSED 10A RANGE PRESS AUTORANGE 300 mA COM V 1 SEC TOUCH HOLD Avoid touching or holding cone ON/OFF switch Battery clip Battery 9V DC Battery door Coiled cable Banana plugs 3 2 1 4 ° C ° F ° C/ ° F switch Figure 1.
Table 1. Display Codes Condition Action 1041 ° F Target temperature is over range. Select target within probe's specified temperature range. -135 ° F The temperature of the probe is near the low ambient operating range limit.** Ensure that the probe is within the specified ambient operating range.
2.5 0.1 14 0.6 7.5 0.3 21 0.8 33 1.3 mm Inch 0 0 25 1 50 2 76 3 130 5 mm Inch Distance to object Diameter of spot Spot size increases with distance from the probe tip, as shown Figure 2.
Measurem ent Consi d erati ons · If t he surf ace t o be measured i s sm all (13 mm (1/2 in.) or less), hol d the probe as cl ose as pos sible to the surf ac e (no m ore t han 50 mm (2 in.) away). · If t he surface to be meas ured is covered by frost or other materi al , c lean it to expos e t he surface.
Output: 1 mV/degree ° F Relative Hum idity: 95% RH or less @ 86° F noncondensing, Temp. Coef. appli es Storage Temperature: -13° to 158° F wi t hout batter y Power: 9V b attery; (N EDA 1604A, 6F22, 006P ) Batt ery life ( Alkaline): 50 hours typical, @ 73° F 33% du ty cycle Dimensions: (L x W x H) 180 m m x 30 mm x 50 m m (7.
LIMI T E D WARRANTY & LIMI T AT I ON OF LIABILI T Y Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. P arts, product repairs, and services are warranted for 90 days.
Servic e For servic e information in t he U.S.A., call 1-800-526- 4711. Outs ide the U.S.A. , contact the nearest Fluke Servic e Center. To locat e an authorized servic e center, visi t us on the World Wi de Web: www.
デバイスFluke 80T-IRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Fluke 80T-IRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFluke 80T-IRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Fluke 80T-IRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Fluke 80T-IRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Fluke 80T-IRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFluke 80T-IRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Fluke 80T-IRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFluke 80T-IRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。