Follettメーカー00119628R01の使用説明書/サービス説明書
ページ先へ移動 of 24
Installation, Operation and Ser vice Manual VU300K Series Integral Cold Carbonation Ice and Be verage Dispenser s 00119628R01 801 Church Lane • PO Box D, Easton, PA 18044, USA Toll free (800) 523-9361 • (610) 252-7301 Fax (610) 250-0696 • www.follettice.
2.
Welcome to Follett Corporation Important cautions Specifications Installation Installing dispenser in counter Field wiring diagrams Connecting beverage lines Installing optional icemaker Operation How.
W elcome to Follett Follett ice dispensers enjoy a well-deserved reputation for excellent performance, long-term reliability and outstanding after-the-sale support. To ensure that this dispenser delivers that same degree of service, we ask that you take a moment to review this manual before beginning the installation of the dispenser.
5 Specifications Electrical Each dispenser requires a separate circuit with electrical disconnect within 10 ft (6m). Equipment ground required. Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 20 amps, Maximum icemaker fuse – 20 amps each.
Front Vie w (shown with two Chewblet FC400A auto-fill icemaker kits) 24.62" (626mm) 30" (762mm) beverage lines enter through bottom 9" (229mm) 9" (229mm) 15" (381mm) 10" (254mm) 2.5" (64mm) 7" (178mm) 3" (77mm) 2" (51mm) 32.
Installation Installing dispenser in counter Note: All dispensers must be supported from below with supplied 4" – 6" (102 – 153mm) adjustable leg accessory, or equivalent. Do not hang dispenser on flange. All dispensers must be installed level in both directions to ensure proper operation.
8 Field wiring diagrams Note: Field wiring diagrams are intended to aid electricians or technicians in understanding how equipment works. All field wiring must be installed in accordance with all local and NEC codes. Connecting bevera ge lines 1. Connect syrup and water lines.
Installing optional auto-fill icemaker kit(s) Correct installation of remote icemaker(s) is critical to proper performance of icemaker. Refer to installation manual packed with icemaker for important details on ice transport tube run, ventilation requirements and other installation requirements.
Operation How the dispenser w orks Follett’s dispensers may be fed by Follett remote icemakers or manually loaded (using ice from another source). In all models, ice is stored below the counter in the dispenser storage area. When the dispense lever or button is pushed, the dispense motors are activated.
Cleaning Using solutions below, clean and sanitize storage area and beverage lines before starting unit and on a routine basis as noted below. Note: Always disconnect power before cleaning dispenser.
Recommended daily dispenser cleaning 1. Remove all debris from drain pan. 2. Pour 1 gallon (4L) hot water into drain pan to keep drain lines clear. Recommended weekly dispenser cleaning 1. Remove drain pan and grille and wash with Solution A. Rinse thoroughly.
Service Dispense chute cover removal 1. Remove top cover. 2. Remove two screws from top cover and pull cover forward and down to remove. 3. On push button units, disconnect plug on harness. Auger motor assembly removal 1. Remove drain pan. 2. Remove thumbscrews from splash guard and remove.
Wiring diagram VU300K series YELLOW YELLOW M3 WHITE BATHPUMP MOTOR (35 MIN ON DELAY) DISPENSE SWITCH LID PL1-1 L1 SWITCH POWER BLACK POWER BLACK TOP LID SWITCH NO C BLACK RED RED 24V RED PL6-1 C M2 MT.
Symptom Ice does not dispense. • Auger motor does not run • Wheel motor does not run Ice does not dispense. • Auger motor runs • Wheel motor runs • Gate does not open Ice does not dispense. • Auger motor does not run • Wheel motor runs Ice does not dispense.
Symptom Carbonator pump not turning on. Carbonator pump is not turning off. Carbonation system is not carbonating. Carbonation system is producing excessively carbonated beverages. Possible cause 1. Loose connection. 2. Electrode connections on carbonator tank are satisfied.
Condition Pump Solenoids Auger Wheel Beverage valves Top lid off OFF ON OFF OFF ON Drain pan off ON ON OFF OFF OFF On/off switch in OFF position OFF OFF OFF OFF OFF Beverage switch in OFF position ON .
Replacement par ts Reference # Description Part # 1 Lid, with graphics, single-sided 00126805 2 Graphics, “Follett” 00116780 3 Access panel, tower, single-sided 00108407 Not shown Cover, ice openi.
1 2 8 10 3 4 9 11 12 13 14 countertop section 4 Top View lower ring Top View auger tube seal Front View auger tube 6 Reference # Description Part # 1 Motor, auger (includes capacitor) 00115212 2 Brack.
VU300 dispense assembly Side View VU300 dispense assembly Top View 2 1 1 4 3 3 7 Reference # Description Part # 1 Gate, dispense 501955 2 Linkage pin, gate/solenoid 502096 3 Pin, quick release, 3".
Reference # Description Part # 1 Pump, waterbath (includes mounting plate and elbow) 00111476 2 Elbow, overflow 1" (26mm) x 3/4 MPT 502465 Not shown Elbow, clean out, drain, 3/8" (10mm) x 3/.
Beverage bath control board detail Cold carbonation level control board detail 24V AC (YEL) NO NC 24V AC (RED) C L2 (WHT) PUMP LID ready MTR COLD WARM BEV .
23.
00119628R01 02/06 801 Church Lane • PO Box D, Easton, PA 18044, USA Toll free (800) 523-9361 • (610) 252-7301 Fax (610) 250-0696 • www.follettice.
デバイスFollett 00119628R01の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Follett 00119628R01をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFollett 00119628R01の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Follett 00119628R01の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Follett 00119628R01で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Follett 00119628R01を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFollett 00119628R01の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Follett 00119628R01に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFollett 00119628R01デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。