Genieメーカー4024の使用説明書/サービス説明書
ページ先へ移動 of 27
Includes INTELLICODE ® 2 Remote Control. Safe-T -Beam ® System must be installed to close door . For use only with residential sectional or one piece overhead garage doors. Homelink ® and Car2U ® compatible. For Answers and Assistance: 1.800.354.3643 or visit www .
©2010 The Genie Company 12/2010 2 SAFET Y INFORMA TION IMPORT ANT SAFET Y INSTRUCTIONS READ AND FOLL OW ALL INSTRUCTIONS SA VE THESE INSTRUCTIONS C ONVENTIONS USED IN THESE INSTRUCTIONS Garage doors are large , heavy objects that move with the help of springs under high t ension and elec tric motors.
SAFET Y FEA TURES Safe-T-Beam® (STB) Non-Contact Rev ersing System Puts an in visible beam across the door opening. The door stops and rev erses to the full open position if anything passes through the beam. LED indicator lights on the powerhead and on the STBs pro vide a self diagnostic code if an operational problem exists.
T ABLE OF C ONTENTS Sec tion .................................................................................... P age Safety Information .................................................................................................... 2 Opener F eatures & Safety F eatures .
Begin here af ter the opener's ph ysical assembly and installation has been c ompleted . Ther e are no assembly or installation steps included in this manual. Contact your Genie® P rofessional Dealer for an installa tion poster , if requir ed , or visit www .
W ARNING • Make sure doorway is in vie w and clear of obstacles and people to av oid injury or damage to proper ty . • DO NO T operate this unit from wall c onsole before LIMITS and FORCE are set. Severe damage to the opener can occur . • The bullet MUST be engaged to carriage BEFORE setting limits.
©2010 The Genie Company 12/2010 7 PR OGRAM SET — SEE long Blue LED flashing 6 W atch door mo ve RA M SET — + B) OPEN DOOR TRA VEL LIMIT NOTICE IF DOOR BECOMES OBSTRUCTED I PULL DOWN ON HANDLE DOOR CL OSES DOOR OPENS Door Limits are set. Both LEDs flash Blue and go OFF .
©2010 The Genie Company 12/2010 8 1 2 3 4 C ONT A CT REVERSE TEST The F orce and Limit settings on the previous page MUST be C OMPLETED before C ontac t Reverse testing . 1. T est . • Open garage door using wall console. – Place a 2" x 4" boar d (laid flat) under center of garage door opening .
©2010 The Genie Company 12/2010 9 PROGRAM SET — + PROGRAM SET — + PROGR AM INTELLIC ODE® 2 REMO TE TO PO WERHEAD FOR HELP-1-800-35-GENIE OR WWW.GENIEC OMP ANY .COM 2 PRESS and HOLD SEE BO TH Blue LEDs come ON SEE round Blue LED come ON SEE long Purple LED flashing RELEASE 1 2 3 4 5 6 7 The next press of the remote will operate door .
©2010 The Genie Company 12/2010 10 PROGRAM SET — + PROGRAM SET — + PRESS and HOLD SEE BO TH Blue LEDs come ON SEE one Blue LED come ON PRESS and release a previously progr ammed Genie® IntelliCode® 2 remot e button on remote . If you ar e unsure which remote you hav e see page 16.
Release Handle Poignée de dév errouillage Palanc a de liberación POWER HEAD TÊTE DE PUISSANCE CABEZA DE LA ENERGÍA Po wer Cor d Cordon de secteur Cable eléctrico Door Arm Bras de la porte Brazo .
©2010 The Genie Company 12/2010 12 NOTICE IF DOOR BECOMES OBSTRUCTED I PULL DOWN ON HANDLE T YPIC AL SECTIONAL DOOR INST ALLA TION FOR HELP-1-800-35-GENIE OR WWW .GENIEC OMP ANY .C OM INST ALLA TION T YPIQUE SUR UNE PORTE SECTIONELLE ................
©2010 The Genie Company 12/2010 13 SECTIONAL DOOR PORTE SECTIONELLE PUERT A SECCIONAL ONE PIECE DOOR PORTE D’UNE PIÈCE PUERT A DE UNA SOLA PIEZA IF DOOR BECOMES OBSTRUCTED I PULL DOWN ON HANDLE LI.
©2010 The Genie Company 12/2010 14 SET PROGRAM Open Tr a v e l Button ROUND LED Indicator (Light) F acing Garage Door L ONG LED Indicator (Light) Close Tr a v e l Button O VERVIEW OF POWERHEAD C ONTROLS This section describes the simple programming functions.
©2010 The Genie Company 12/2010 15 O VERVIEW - REMO TES AND OPTIONS 5 FC C and IC CERTIFIED This device complies with FC C P ar t 15 and RSS 210 of Industr y Canada. This equipment has been tested and f ound to comply with the limits for a Class B digital device , pursuant to Part 15 of the FC C Rules.
©2010 The Genie Company 12/2010 16 3. Press the same button twice to toggle IntelliC ode® selection from IntelliCode® 2 to IntelliCode® 1. INTELLIC ODE® FEA TURES Other models of G enie® garage door openers, remotes , and wireless keypads use IntelliC ode® 1 signals to communicate.
©2010 The Genie Company 12/2010 17 MAINTENANCE & TROUBLESHOO TING FOR HELP-1-800-35-GENIE OR WWW .GENIECOMP ANY .COM 6 If you hav e any questions, please do not hesitate to contact customer ser v.
• With the door closed , pull release handle DOWN and let go to release door carriage assembly from drive syst em. • Raise door manually approximately 3’- 4’ and release. – Door should remain stationar y or move v er y slightly . – If door moves quickly , CONT ACT A TRAINED DOOR SY STEM TECHNICIAN .
NOTICE IF DOOR BECOMES OBSTRUCTED PULL DOWN ON HANDLE TO RELEASE CARRIA GE: 1. Pull handle DOWN then let go . 2. Manually move door until carriage r eleases from bullet. 3. Raise or lower door manually. DOOR PULL TO REC ONNECT CARRIAGE: 1. Verify RED block is in the UP position.
©2010 The Genie Company 12/2010 20 Independent Light Control Button Controls door opener lights fr om inside garage Sure-Lock™ Button – L OCK disables controls after door is completely closed –.
CHAIN OR BEL T - TENSION ADJUSTMENT W ARNING • Obser ve all safety warning and precautions! • Disconnect power from opener and disconnect carriage in rail from bullet bef ore beginning this task. Visually inspec t the chain or belt every 6 months.
©2010 The Genie Company 12/2010 22 ADJUSTMENT GUIDE - SPEED SETTINGS FOR HELP-1-800-35-GENIE OR WWW .GENIEC OMP ANY .C OM Speed settings are pre-progr ammed at the fac tory for the maximum speed . Speed settings should not need adjustment with this unit.
©2010 The Genie Company 12/2010 23 ADJUSTMENT GUIDE - FORCE SET TINGS FOR HELP-1-800-35-GENIE OR WWW .GENIEC OMP ANY .C OM F orce settings are pre-pr ogrammed at the fac tory and "learned" during the Open/Close Limit settings steps. Some additional For ce may be increased .
PROBLEM WHA T TO DO Opener does NO T run from wall c onsole. • Check power source , – Plug a lamp into outlet used for pow erhead. If lamp works, pow er source is OK. – If not, check fuse or circuit breaker . • I f power is OK, – Check connections at powerhead terminals and at wall console .
PROBLEM WHA T TO DO Noisy operation. • Be sure all door fasteners are tight. • Be sure garage door is in good repair , properly lubricated and balanc ed. • Be sure opener is in good repair . Door opener runs slow . • Check operating condition of door .
©2010 The Genie Company 12/2010 26 REFERENCE - CIRCUIT WIRING DIA GRAM FOR HELP-1-800-35-GENIE OR WWW .GENIECOMP ANY .COM RÉFÉRENCE - DIAGRAMME DE CÂBLA GE DE CIRCUIT ........................................................POUR OBTENIR DE L ’AIDE-1-800-35-GENIE REFERENCIA - ESQUEMA ELÉCTRIC O DEL CIRCUITO .
GMI Ho ldings, Inc . d/b/a The Genie Company ("S eller") wa rrants to t he origina l purchaser of the bel ow identif ied garage door opene r, I ntelliG ™ 12 00 (Model 4024 a nd 4024H) ( .
デバイスGenie 4024の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Genie 4024をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGenie 4024の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Genie 4024の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Genie 4024で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Genie 4024を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGenie 4024の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Genie 4024に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGenie 4024デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。