Graco Inc.メーカー311053Eの使用説明書/サービス説明書
ページ先へ移動 of 30
311053E Instructions - Parts Automatic Airless Spray Guns Part No. 288048 For airless spraying of paints and coatings. Part No. 288554 For sealant streaming applications. 4000 psi (28 MPa, 280 bar) Maximum Working Fluid Pressure Mounting manifolds must be ordered separately.
Related Manuals 2 311053E Contents R e l a t e dM a n u a l s ........................... 2 W a r n i n g s ................................. 3 I n s t a l l a t i o n ................................ 5 Ventilate Spray Booth ..................... 5 Configure Gun and Manifold .
Warnings 311053E 3 Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings.
Warnings 4 311053E PRESSURIZED EQUIPMENT HAZARD Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.
Installation 311053E 5 Installation Ventilate Spray Booth Configure Gun and Manifold (Order manifold separately. See Accessories , page 26.) Manifolds 241161 and 241162 The gun is supplied with an internal fluid plug (4). See F IG . 1. To use the gun in a circulating system, remove the internal plug.
Installation 6 311053E Install Air Fittings 1. Install 1/4 in. tube fitting into the cylinder (CYL) air port. 2. Install plugs into the atomization (ATOM) air port and the fan (FAN) air port. Ground System The following grounding instructions are minimum requirements for a system.
Installation 311053E 7 Mount Gun Reciprocating Arm Rod Mount Manifolds 241161 and 241162 To mount the gun on a reciprocating arm rod [0.5 in. (13 mm) diameter maximum]: 1. Insert the mounting bar (A) through the hole in the manifold as shown in F IG .
Setup 8 311053E Setup Air Line and Accessory Recommendations 1. Install an air pressure regulator on the gun cylinder air supply line. A minimum of 70 psi (0.49 MPa, 4.9 bar) air pres- sure must be supplied to the cylinder for proper operation. Air pressure opens the valve, a spring closes the valve.
Setup 311053E 9 Manifolds 288219 and 288220 6. In a circulating system , connect an electrically con- ductive fluid hose to the gun fluid outlet (G). In a non-circulating system , remove the gun fluid outlet fitting (G) and plug the outlet port with the pipe plug (109) supplied.
Setup 10 311053E Flush Spray Gun Before running any paint through the spray gun: 1. Flush the gun with a solvent that is compatible with the fluid to be sprayed, using the lowest possible fluid pressure and grounded metal container. 2. Perform Pressure Relief Procedure ; see page 11.
Operation 311053E 11 Operation Pressure Relief Procedure 1. Shut off the power to the pump. 2. Turn off the air and fluid supply to the gun. 3. Close the bleed-type master air valve (required in the system). 4. Trigger the gun into a grounded metal waste con- tainer to relieve the fluid pressure.
Daily Gun Care 12 311053E Daily Gun Care CAUTION Methylene chloride with formic or propionic acid is not recommended as a flushing or cleaning solvent with this gun as it will damage aluminum and nylon compo- nents. CAUTION Solvent left in gun air passages could result in a poor quality paint finish.
Daily Gun Care 311053E 13 General System Maintenance • Perform Pressure Relief Procedure , page 11. • Clean the fluid and air line filters daily. • Check for any fluid leakage from the gun and fluid hoses. Tighten fittings or replace equipment as needed.
Troubleshooting 14 311053E Troubleshooting General Troubleshooting Check all possible remedies in the troubleshooting charts before disassembling the gun. Some improper patterns are caused by the improper balance between air and fluid. Refer to Spray Pattern Troubleshooting , page 16.
Troubleshooting 311053E 15 Fluid needle will not trigger Loose or missing fluid needle stop (17) or setscrew (16). Broken fluid needle (12). Air leaking around piston (21). Swollen piston o-ring (22). Insufficient air pressure on the trig- ger. Spray tip (9) is plugged.
Troubleshooting 16 311053E Spray Pattern Troubleshooting Problem Cause Solution Fluttering spray. Insufficient fluid supply. Air in paint supply line. Adjust fluid regulator or fill fluid sup- ply tank. Check, tighten siphon hose connec- tions, bleed air from paint line.
Service 311053E 17 Service Disassembly 1. Follow Pressure Relief Procedure , page 11. 2. Unscrew the four screws (14) and remove the gun from the manifold. 3. Unscrew the tip retainer nut (7). Remove the spray tip (9) and gasket (8). See Figs. 8 and 9.
Service 18 311053E F IG .1 3 SERVICE NOTES: Seat gasket (11) must be replaced if seat (10) is removed or replaced to avoid fluid leakage Lubricate threads with anti-seize lubricant Lubricate with light-weight oil Do not lubricate Torque to 20-25 ft-lb (27-34 N•m) Apply semi-permanent anaerobic sealant Torque to 4-5 in-lb (0.
Service 311053E 19 Reassembly 1. Perform the following applicable step: • Non-circulating Paint Guns: Lubricate the backup (6) and o-ring (5) and install them on the fluid outlet port plug (4). Install the plug in the fluid outlet port of the fluid housing (2).
Parts 20 311053E Parts Model 288048 F IG .1 4 SERVICE NOTES: Seat gasket (11) must be replaced if seat (10) is removed or replaced to avoid fluid leakage Lubricate threads with anti-seize lubricant Lubricate with light-weight oil Do not lubricate Torque to 20-25 ft-lb (27-34 N•m) Apply semi-permanent anaerobic sealant Torque to 4-5 in-lb (0.
Parts 311053E 21 Model 288554 F IG .1 5 SERVICE NOTES: Seat gasket (11) must be replaced if seat (41) is removed or replaced to avoid fluid leakage Lubricate threads with anti-seize lubricant Lubricate with light-weight oil Do not lubricate Torque to 20-25 ft-lb (27-34 N•m) Apply semi-permanent anaerobic sealant Torque to 4-5 in-lb (0.
Parts 22 311053E Parts * Parts included in Air Seal Repair Kit 288171 (pur- chase separately). The kit includes some parts that are not used on this gun. † Parts included in Fluid Seal Repair Kit 239896 (pur- chase separately). ★ An extra gasket (3) is included as a spare.
Parts 311053E 23 Part No. 241161 North America Manifold Part No. 241162 International Manifold ❖ Part No. 241161 only. ◆ Part No. 241162 only. Part No. 244930 High Flow Ambient or Temperature Conditioned Mani- fold for streaming or spraying. Ref. No.
GG0 Series Tip Selection Charts 24 311053E GG0 Series Tip Selection Charts GG0 Series Spray Tips Orifice Size in. (mm) * Fluid Output oz/min (lpm) at 600 psi (4.1 MPa, 41 bar) Maximum Pattern Width at 12 in. (300 mm) 2t o2 . 5 (50) 4t o4 . 5 (100) 6t o6 .
Sealer Application Tip and Air Cap Selection Charts 311053E 25 Sealer Application Tip and Air Cap Selection Charts Shower Tip Streaming Tips Single Orifice Fan Pattern Spray Tips No. of Orifices Orifice Size in. (mm) Part. No. 6 0.021 (0.533) C08224 Orifice Size in.
Accessories 26 311053E Accessories Gun Manifolds Order separately; not included with gun. (See Parts , page 22.) Part No. 241161 North America Manifold Part No. 241162 International Manifold Part No. 244930 High Flow Ambient or Temperature Conditioned Mani- fold for streaming or spraying.
Dimensions 311053E 27 Dimensions F IG .1 9 TI8113a TI8114a 2.0 in. (50.8 mm) 3.86 in. (98.0 mm) 5.23 in. (139.7 mm) 3.0 in. (76.2 mm) 1.375 in. (34.9 mm) 2.
Mounting Hole Layout 28 311053E Mounting Hole Layout F IG . 20: Manifold Mounting Hole Layout 0.4 in. T w oM 5x0 . 8x0 . 2 5i n . 0.805 in. (20.5 mm) 0.187 in. (4.8 mm) 1.375 in. (35 mm) Two 0.128 diameter x 0.31 in. (7.8 mm) deep 2.125 in. (54 mm) holes (for alignment pin) Remove set screws when using bottom mounting pattern.
Technical Data 311053E 29 Technical Data Triggering Speed These values apply to a new gun wit ha6f t( 1 . 8m ) ,1 / 4i n .( 6 . 3m m )O Dc y l i nder air line and a 0.019 in. tip. These values will vary slightly with use and with variations in equipment.
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. This manual contains English. MM 311053 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC.
デバイスGraco Inc. 311053Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco Inc. 311053Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco Inc. 311053Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco Inc. 311053Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco Inc. 311053Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco Inc. 311053Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco Inc. 311053Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco Inc. 311053Eに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco Inc. 311053Eデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。