3A2799A EN Instructions - Parts XHF Spray Gun For spraying viscous materials at high flow rates. For professional use only. Part No. 262854, Series A Includes an XHD ™ RAC ® Guard and XHD429 SwitchTip ™ 7250 psi (50 MPa, 500 bar) Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual.
2 3A2799A Contents W a r n i n g s ................................. 3 Operation ................................. 5 System Requirements ..................... 5 Ground the System ....................... 5 Gun Trigger Lock ........................ 5 Pressure Relief Procedure .
Warnings 3A2799A 3 Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks.
Warnings 4 3A2799A EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system com- ponent.
Operation 3A2799A 5 Operation Keep the wallet-sized warning card provided with this gun with the operator at all times. The card contains important treatment information should an injection injury occur. Additional cards (part no. 222385) are available at no charge from Graco.
Operation 6 3A2799A Operation 1. Connect a fluid hose (A) to the gun inlet. Use high pressure swivel 207946 if desired (order sepa- rately). See Fig. 2. 2. With SwitchTip (8) and tip guard (9) removed, start the pump. Flush the pump according to the instruc- tions supplied with it.
Operation 3A2799A 7 Gun Care Cleaning during the day 1. Relieve pressure, page 5. 2. Use a solvent-soaked brush to clean the spray tip. Clean the front of the tip frequently during the day to help reduce buildup. 3. Clean the tip and tip guard at the end of each work day.
Operation 8 3A2799A Flush the Gun NOTE: This procedure requires a grounded pail of com- patible flushing fluid. 1. Relieve pressure. 2. Remove the tip guard and spray tip. Soak and clean the parts. 3. Single component systems only: Remove the pump intake from the original pail.
Service 3A2799A 9 Service Disassembly for Repair or Cleaning NOTE: If replacing only the needle and seat, step 4 and 5 are not required. However, removing them allows you to clean the gun more thoroughly. 1. Relieve pressure. 2. Disconnect the fluid hose (A) and swivel (if used).
Service 10 3A2799A 5. Loosen the setscrew (15) then remove the fluid housing (22) from the gun body (1). See F IG .8 . 6. While supporting the spring guide (16) to prevent bending the needle (2c), loosen the setscrews (17) then remove the spring guide (16).
Service 3A2799A 11 3. Place the gasket (2b) on the valve seat (2a). Grease the threads of the valve seat (2a) then install into the fluid housing (22). Torque to 20-25 ft-lb (27-34 N•m). See F IG .1 3 . 4. Install the spring guide (16) and seat it against the needle.
Service 12 3A2799A 7. Position the trigger (24) on the gun body. Insert the pivot pin (23) into the top hole (A) and secure with the screw (13) on the other side.
Parts 3A2799A 13 Parts --- Not for sale. ▲ Replacement Danger and Warning labels, tags and cards are available at no cost. 9 8 2a 2b 2c 22 2e 2d 17 17 18 26 26 19 20 15 13 21 23 1 24 16 ti19282a 1 Must install as shown with the notch on the bottom.
Parts 14 3A2799A Needle and Seat Kits The needle and seat are available only in kits that include items 2a through 2e. The standard non-diffused needle and seat kit, 237260, includes all OEM parts and has the number 125 stamped on the needle and seat.
Technical Data 3A2799A 15 Technical Data * Sound pressure measured 3.3 feet (1 meter) from equipment. ** Sound power measured per ISO-9614-2. Maximum Working Pressure ..................... 7250 psi (50 MPa, 500 bar) Fluid orifice size ................
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. )RUSDWHQWLQIRUPDWLRQVHHZZZJUDFRFRPSDWHQWV 2ULJLQDOLQVWUXFWLRQV This manual contains English.
デバイスGraco Series Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco Series Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco Series Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco Series Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco Series Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco Series Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco Series Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco Series Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco Series Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。