695/795 Premium Hi-Bo y 695/795 MARK V 1095/1595 Premi um Hi-Boy ti15036b ti15034a ti15035b ti14838b For Portable Airless Spraying of Architectural Coatings and Paints. For professional use only. Not approved for use in Euro pean explosive atmoshere locations.
Models: 2 3A0157B Models: 695 UL TRA MAX lIl Model QuikReel Hi-Bo y Lo-Bo y 258719 ✓✓ 258720 ✓ 258722 ✓ 258872 ✓ 258873 ✓ 258874 ✓ 258876 ✓ 258877 ✓✓ 826124 ✓✓ 826125 ✓ 82612.
Table of Contents 3A0157B 3 T able of Contents Models: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 T a ble of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . 3 W arnings . . . . . . . . . . . . . . . . . . . . .
Warnings 4 3A0157B Wa r n i n g s The f ollowing w ar nings are f or the setup , use, g rounding, maintenance and re pair of this equipment. The e xclamation point symbol alerts you to a ge neral warning and the hazar d symbol refer s to procedure-specific risks.
Warnings 3A0157B 5 FIRE AND EXPLOSION HAZARD Flammable fumes , such as solvent and paint fumes , in work area can ignite or explode . T o help pre vent fire and e xplosion: • Do not spra y flammable or comb ustible materials near an open flame or sources of ignition such as cig- arettes, motors , and electr ical equipment.
Warnings 6 3A0157B W ARNING EQUIPMENT MISU SE HAZARD Misuse can cause death or serious injur y . • Alwa ys wear appropriate glov es, e ye protection, and a respirator or mask when painting. • Do not operate or spra y near children. K eep children awa y from equipment at all times.
Component Identi fication 3A0157B 7 Component Identification ti14839b 11. 12. 10. 13. 1. 2. 4. 5. 6. 7. 8. 9. 3. 1 Premium Digital Display 2 ON/OFF s witch 3 W atchDog ™ Switch (not a va ilable on M.
Pressure Relief Procedure 8 3A0157B Pressure Relief Pr ocedure 1. T urn power OFF . Wait 7 seconds for power to dissipate. 2. Lock gun trigger sa f ety . Remov e guard and SwitchTip . 3. T urn pr essure to lowest set ting. T rigge r gun to relie ve pressure.
Grounding 3A0157B 9 Gr ounding The spra yer must be g rounded. Grounding reduces the risk of static and electric shock by pro viding an escape wire f or the electrical current due to static build up or in the e vent of a shor t circuit. The spra yer cord includes a ground ing wire with an appropriate gro unding contact.
Troubleshooting 10 3A0157B T r oubleshooting Mechanical/Fluid Flo w Pe r f o r m Pressure Relief Procedure ; page 8. TYPE OF PR OBLEM WHA T T O CHECK If chec k is OK, go to next ch eck WHA T T O DO When check is not OK, refer to this column E=XX is display ed 1.
Troubleshooting 3A0157B 11 Pump output is low 1. Spra y tip wor n 1. F ollow Pressu re Relief Procedure on page 8, then replace t ip. See y o ur sepa- rate gun or tip manual. 2. Spra y tip clogged 2. Relie ve pressure . Check and clean spr ay tip . 3.
Troubleshooting 12 3A0157B Motor runs b ut pump does not strok e 1. Displacement pump pin ( 32) damaged or missing; see pump manual 310643 or 310894. 1. Replace pump pin if missing. Be sure retainer spr ing ( 31) is fully in groov e all around connecting rod; see pump manual 310643 or 310894 .
Troubleshooting 3A0157B 13 Electrical Symptom: Sp rayer does not run or stops runn ing. Perform Pressure Rel ief Procedure ; page 8. • Plug spra yer into correct voltage , grounded outlet • Set pow er s witch OFF for 30 seconds and then ON again (this ensures spra yer is in normal run mode).
Troubleshooting 14 3A0157B Spra yer does not run at all Check transducer or transducer connections (contro l board is not detecting a pressure signal). 1. Set spray er to OFF and disconn ect power to spray er. 2. Check transducer and connections to control board.
Troubleshooting 3A0157B 15 Spra yer does not run at all Control is commandin g motor to r un but motor shaft does not rotate . P ossibly loc ked rotor condition, an open connection exists between motor and control, there is a prob lem with motor or co ntrol board, or motor amp draw is e xcessive .
Troubleshooting 16 3A0157B Spra yer does not run at all Control is commanding motor to r un but motor shaft does not rotate. P ossibly lock ed rotor conditi on, an open connection exists between motor and control, there is a problem with motor or cont rol bo ard, or motor amp draw is e xcessive.
Troubleshooting 3A0157B 17 Spra yer does not r un at all Allow spray er to cool. If spray er r uns when cool, correct cause of ov erheating. Keep spra yer in cooler location with good ventilation. Make sure motor air intake is not bloc ked. If spra yer still does not r un, follow Step 1.
Troubleshooting 18 3A0157B Spra yer Will Not Shut Off 1. P erform Pressure Relief Procedure ; page 8. Lea ve prime v alve open and power s witch OFF . 2.
Troubleshooting 3A0157B 19 Spra yer Will Not Run (See f ollowing page f or steps) Remove control box cover. Turn sprayer ON. Observe control board status l ight on control board (see page 13).
Troubleshooting 20 3A0157B 110-120 AC V - + - 110-120 AC V - + - - 100k ohm + - STEP 1: Plug power cord in and turn switch ON. Connect wires to control board and on/off switch. T ur n meter to A C V olts. STEP 2: Plug power cord in and tur n switch ON.
Troubleshooting 3A0157B 21 240 V A C and 110 V A C Motor Control Boar d Re m ova l P erform Pressure Relief Pr ocedure ; page 8. Wait 5 minutes before servicing. 1. Remov e Mo tor Shroud (f or units equip ped with Hose Reel only): a. Remov e bolts fr om motor shrou d.
Troubleshooting 22 3A0157B 5. Make s witch dip s witch is moved t o the left (tow ard inside of board ). See Wiring Diagram , page 40. 6. Connect motor connectors ( F , G and H) and install into baffl e. 7. Connect transduc er connec tor (E) to m otor control board.
Troubleshooting 3A0157B 23 240 V A C Filter Boar d P erform Pressure Re lief Proc edure ; page 8. Re m ova l 1. Remove four screws (38) and cov er (9 6). 2. Disconnect display connector (A) from mo tor control board (52). 3. Remove bo ttom two sc rews (39).
Troubleshooting 24 3A0157B Pressure Adjust P otentiometer Re m ova l Pe r f o r m Pressure Relief Pr ocedure ; page 8. Wait 5 minutes before servicing. 1. Remove four screws (38) and cov er (9 6). 2. Remove two screws and contr ol panel. 3. Disconnect potentiometer co nnector (C) from motor control board (95) .
Troubleshooting 3A0157B 25 Pressure Contr ol T ransducer Re m ova l P erform Pressure Relief Pr ocedure ; page 8. Wait 5 minutes before servicing. 1. Remove four screws (38) and cov er (9 6). 2. Disconnect transducer connector (E) from motor control board (95) .
Troubleshooting 26 3A0157B Installation 1. Install o-ring (20) and transducer (86) in filter base (67). T or que to 35-45 ft- lb (47-61 N•m). Inst all grom- met onto tr ansducer (86) and t ransducer into co ntrol box. 2. Connect transducer connector (E), W atchDog s witch, and reed s witch connector to control board (95).
Notes 3A0157B 27 Notes.
Drive and Bearing Ho using Replacement 28 3A0157B Drive and Bearing Housing Replacement Disassembl y Pe r f o r m Pressure Relief Procedure ; page 8. 1. Remov e screw (31), tw o nuts (24), pail hanger ( 55) and pump rod co ver (108 ). 2. Remove pump (91); see Displacement Pump Replacement , page 32 (695/795) page 34 (1095/1595/ Mark V).
Drive and Bearing Housing Replacement 3A0157B 29 158 55 24 31 72 91 108 51 14 12 83 85 6 90 84 31 ti14892 a Drive and Bearing Housing Replacement.
Motor Replacement 30 3A0157B Motor Replacement Remo val Pe r f o r m Pressure Relief Procedure ; page 8. 1. Remove pump (91); see Displacement Pump Replacement , page 32 (695/795) page 34 (1095/1595/ Mark V). 2. Remov e dr iv e housing (90); see Drive Housing Replacement , page 28 .
Motor Replacement 3A0157B 31 ti14893a 158 90 28 90a 36 19 61 84 58 14 12 158 6 68 39 30 89 51 31 19 23 12 6 90 91 14 96 Motor Replacement.
Displacement Pump Replacem ent for 695/795/Mark IV 32 3A0157B Displacement Pump Replacement f or 695/795/Mark IV See pump manu al 310643 or 310894 f or pump repair instru ctions. See manual 3A01 58 for app licable spr ay er par t number references. Remo val 1.
Displacement Pump Replac ement for 695/795/Mark IV 3A0157B 33 Installation If pump pin works loose, parts could break off due t o f orce of pumping action. P ar ts could project through the air and result in serious injury or proper ty damage. 1. Extend pump piston rod 1.
Displacement Pump Replacement 1095/1595/Mark V 34 3A0157B Displacement Pump Repl acement 1095/1595/Mark V Remo val 1. Flush pump . 2. Stop pump with piston rod in its lowest po sition. 3. P erform Pressure Relief Pr ocedure , page 8. 4. Separate dra in hose from spra yer .
Displacement Pump Replacement 1095/1595/Mark V 3A0157B 35 f . Place u-bolt on pum p door protr usion . 8. Ratchet pump door f orwar d. 9. Open pump do or . 10. Pull out pump pin and place in pi n holder . Installation 1. Adjust piston rod with pin holder to pull ou t piston rod.
Displacement Pump Replacement 1095/1595/Mark V 36 3A0157B 4. Close pump do or and rota te latch into position. Do not tighten latch. 5. Rotate pump to align with paint hose . Connect paint hose and hand ti ghten to 70 in-lb . 6. Tighten latch and rotate la tch lock into lock ed po si- tion.
Hose Reel 3A0157B 37 Hose Reel Remo val 1. Remov e hose fitting from s wivel cap an d completely remov e hose. 2. Remove cap from swiv el. 3. Remove E-clip from s wivel shaft. 4. Remove s wivel. 5. Remov e snap r ing. 6. Remov e hose reel. Be sure to k eep y our head clear o f hose reel while winding up hose.
Hose Reel 38 3A0157B Installation 1. Grease sha ft. 2. Make sure two washers and wav e spr ing ar e on hub bef ore hose reel is installed. 3. Install hose reel onto frame . Place C-clamp on reel and frame to allow snap r ing to fit into place. Install snap ring.
Reed Switch Replacement 3A0157B 39 Reed Switch Replacement Remo val 1. Remov e four scre ws and remo ve displa y cov er . 2. Remov e two screws and remo ve con trol panel. 3. Unplug reed s witch from control board. 4. Unscrew reed s witch from control panel.
Wiring Diagram 40 3A0157B Wiring Diagram 120V Models: ti13485a Pressure T ransducer Digital Display ON/OFF Switch Power Plug Black + white green/ground Motor green/ground Potentiometer AutoClean Black.
Wiring Diagram 3A0157B 41 120V Models (with 15/20 Amp Switch): Black Pressure T ransducer Digital Display ON/OFF Switch Power Plug Black + white green/ground Motor green/ground Potentiometer 1595 Swit.
Wiring Diagram 42 3A0157B 240V Models: Black Pressure T ransducer Digital Display ON/OFF Switch Power Plug Motor green/ground Potentiometer AutoClean W atchdog Motor Leads Motor Sensor Leads Thermal S.
Notes 3A0157B 43 Notes.
All written and visual data contained in this document reflects the latest product info rmation available at th e time of publica tion. Graco reserves the right to make changes at any time without notice. This manual contains English. MM 3A0157 Graco Headquarters: Mi nneapolis Internationa l Offices: Belgium, China, Japan, Korea GRACO INC.
デバイスGraco ti15034aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco ti15034aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco ti15034aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco ti15034aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco ti15034aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco ti15034aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco ti15034aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco ti15034aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco ti15034aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。