GTOメーカーUL325 SERIESの使用説明書/サービス説明書
ページ先へ移動 of 45
© 2004 GTO, Inc. R350INST rev - 04/11/06 Installation Manual for the W ARNING! This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325).
VEHICULAR GA TE OPENER CLASS CA TEGORIES Residential V ehicular Gate Opener -Class I : A vehicular gate opener (or system) intended for use in a home of one-to-four single family dwelling, or a garage or parking area associated there with.
Gate Opener Class Categories ------------------------------------------------------------- inside cov er Units and Standards Con version Chart --------------------------------------------------- insid.
PLEASE READ THIS FIRST! iii BEFORE Y OU BEGIN T O INST ALL Y OUR A UTOMA TIC GA TE OPENER: watch the enclosed videotape and read these instructions carefully and completely to become familiar with all parts and installation steps. The video tape is only designed as a over view of the installation procedur e.
1 IMPORT ANT SAFETY INSTRUCTIONS Because automatic gate openers produce high le vels of force, consumers need to know the potential hazards associated with improperly designed, installed, and maintained automated gate opener systems. K eep in mind that the gate opener is just one component of the total gate operating system .
2 IMPORT ANT SAFETY INSTRUCTIONS For The Consumer W ARNING: T o r educe the risk of injury or death: 1. READ AND FOLLO W ALL INSTR UCTIONS. Failure to meet the requirements set forth in the instruction manual could cause se vere injury and/or death, for which the manufacturer cannot be held responsible.
3 IMPORT ANT SAFETY INSTRUCTIONS Moving Gate Area Driveway 10' 10' 10' 10' NEVER INST ALL any control device within gray area Entrapment Zones for a proper Pull-T o-Open installation: Zone 1 – leading edge of the gate and the fence post.
4 IMPORT ANT SAFETY INSTRUCTIONS III. After Installation 1. Attach the warning signs ( included ) to each side of the gate to alert the public of auto matic gate operation.
5 IMPORT ANT SAFETY INSTRUCTIONS ENTRAPMENT ALARM (UL 325; 30A.1.1A) The Mighty Mule® E-Z Gate Opener is designed to stop and re verse within 2 seconds when the gate comes in contact with an obstruction.
6 IMPORT ANT SAFETY INSTRUCTIONS Install W arning Signs Entrapment Protection GTO’ s inherent obstruction settings, ev en when properly adjusted, may not be sensitive enough to prevent bodily injury in some circumstances .
7 IMPORT ANT SAFETY INSTRUCTIONS ! Wa rning signs (2 enclosed) to be installed on each side of the gate (3–5 feet above the bottom of the gate) Pr oduct identification label (1) installed under r ear mount on arm. Logo and warning labels (2) installed on each side of opener housing 1-800-543-GA TE (4283) • www .
8 P arts List - Opener and Mounting Hardware Hairpin Clip (2) 3/8" x 1-1/2" Clevis Pin (2) 5/16" x 1-3/4" Bolt (1) 3/8" x 2" Bolt (1) 3/8" x 3" Bolt (2) 3/8&quo.
9 T ools Needed • Power Drill • Open End Wrenches — 3 / 8 ", 7 / 16 ", 1 / 2 ", and 9 / 16 " • 3 / 8 " Drill Bit • Hacksaw or Hea vy Duty Bolt Cutters • Small (Fla.
10 DRIVE • Lo w friction screw driv e (linear actuator) rated for -5 ºF to +160 ºF (-28 ºC to +71 ºC). • Po wered by a 12 V motor with integral case hardened steel gear reducer . Motor speed reduced to 260 rpm. Generates 520 inch lb. of torque at 12 V .
11 Preparation of the Gate Step 1 The gate must be plumb, le vel, and swing freely on its hinges. Wheels must not be attached to the gate. The gate must mov e throughout its arc without binding or dragging on the ground . Note that gates o ver 250 lb.
12 Thin Walled Tube Gate Steel Pipe Cut in Half Gate Bracket Gate Bracket Wood or Metal Reinforcement Gate Bracket Panel Gate 1" x 6" Wood Reinforcement (not supplied) (not supplied) Installation of Mounting Hardware The position of the post bracket determines the le verage and efficiency of the opener .
13 Determining the Mounting P osition of the P ost Bracket Assembly and the Gate Brack et Step 5 W ith the gate in the open position (up to 110º from its closed position), and the opener fully retracted, adjust the post bracket assembly and gate bracket until the opener is le vel.
14 Gate in the CL OSED POSITION Pinch Area Gate in the OPENED POSITION Pinch Area 2" minimum 2" minimum Be sure gate opener and bracket don't bind.
15 Installing the P ost Bracket Assembly and Gate Brack et Step 7 Mark reference points for bolt holes on the fence post through middle of bracket slots. Marking reference points in this manner allows room for adjustment when mounting the post brack et assembly and gate bracket.
16 Mounting the Opener Step 11 Attach the opener to the securely bolted post bracket assembly and gate bracket using cle vis pins, bushings, and hairpin clips, or optional Pin Locks (see Accessory Catalog ). V erify that the opener is lev el and adjust the post bracket assembly if necessary .
17 At this stage of the installation, the opener should be installed on the gate and the closed position stop should be in place. Check List • The gate is plumb, le vel, and swings smoothly on its hinges. • A plate or support was added for the gate bracket (if necessary).
18 P owering the System IMPORT ANT : • The Mighty Mule 350 is designed and intended for use with a 12 V olt automotiv e or marine type battery . The battery must be placed inside a weatherproof case and located within 6 feet of the opener arm. The 10 foot harness supplied connects the battery to the opener arm.
19 Step 2 Place the 12 V olt automotiv e or marine type battery and its weatherproof case within 6 feet of the fence post where the opener arm is mounted.
20 ON/OFF – o Battery Harness Wi res Tr ansformer Wires Receiver Wires Accessory Wi res Neatly arrange all wires to lay flat as they come out of the opener .
21 GT O indoor Tr ansformer (surge protector not supplied) Run 1000' (max.) of low voltage wire to control board from transformer (wire not included) . PVC conduit (not included) to protect wire from lawn mowers and weed eaters. Step 5 Select the 120 V olt electrical outlet into which you will plug the transformer .
22 Step 9 Plug the transformer into the electrical outlet. (Use of a surge protector with the transformer is strongly recommended.) Step 8 At the AC outlet strip 1 / 2 " of insulation from the ends of the lo w voltage wire. Attach these stripped ends to the transformer terminals.
23 1 ON 234 15 CHARGING POWER S TAT US RF PUL L- PUSH MODE1 MODE2 LO CK/BEACON OFF 120 MIN MAX STALL FORCE CLOSE TIME SET LIMIT LEARN REMOTE AU X OUT SOLAR PA NEL 18VAC RCVR GRN BLK RED EXIT SAFETY ED.
24 Y our Mighty Mule 350 has two Limit Settings 1) OPEN Limit setting: (Gate in the OPEN POSITION / F ACT OR Y SET & NO T ADJUST ABLE) The open limit setting is the fully open position.
25 1 ON 234 15 CHARGING POWER ST AT US RF PUL L- PUSH MODE1 MODE2 LO CK/BEACON OFF 120 MIN MAX STALL FORCE CLOSE TIME SET LIMIT LEARN REMOTE AU X OUT SOLAR PA NEL 18VAC RECR GRN BLK RED EXIT SAFETY ED.
26 1 ON 234 15 CHARGING POWER S TAT US RF PUL L- PUSH MODE1 MODE2 LO CK/BEACON OFF 120 MIN MAX STALL FORCE CLOSE TIME SET LIMIT LEARN REMOTE AU X OUT SOLAR PA NEL 18VAC RECR GRN BLK RED EXIT SAFETY EDGE CYCLE COMMON LINK LEARN REMOTE Button 2.
27 Installing the R eceiver Use the transmitter to c heck the rang e of the receiver bef ore permanently mounting it . Consider the follo wing when mounting the receiver: • Standard recei ver cable length is 10 feet (receiv ers with a longer cable are av ailable as special order items; call the GTO Sales Department ).
28 Connecting Additional Safety Devices The Mighty Mule® 350 is equipped with built-in obstruction sensiti vity . The opener is designed to stop and re verse the gate for 2 seconds when it comes in contact with an obstruction.
29 1 ON 234 15 CHARGING POWER S TAT US RF PUL L- PUSH MODE1 MODE2 LO CK/BEACON OFF 120 MIN MAX STALL FORCE CLOSE TIME SET LIMIT LEARN REMOTE AU X OUT SOLAR PA NEL 18VAC RECR GRN BLK RED EXIT SAFETY ED.
30 Wi res from Accessory 1 ON 234 15 CHARGING POWER S TAT US RF PUL L- PUSH MODE1 MODE2 LO CK/BEACON OFF 120 MIN MAX STALL FORCE CLOSE TIME SET LIMIT LEARN REMOTE AU X OUT SOLAR PA NEL 18VAC RECR GRN .
31 1 ON 234 15 CHARGING POWER S TAT US RF PUL L- PUSH MODE1 MODE2 LO CK/BEACON OFF 120 MIN MAX STALL FORCE CLOSE TIME SET LIMIT LEARN REMOTE AU X OUT SOLAR PA NEL 18VAC RECR GRN BLK RED EXIT SAFETY ED.
32 1 ON 234 15 CHARGING POWER S TAT US RF PUL L- PUSH MODE1 MODE2 LO CK/BEACON OFF 120 MIN MAX STALL FORCE CLOSE TIME SET LIMIT LEARN REMOTE AU X OUT SOLAR PA NEL 18VAC RECR GRN BLK RED EXIT SAFETY ED.
33 Gate in the Closed Position Pinch Area (gray) Gate in the Open Position Pinch Area (gray) 2" minimum 2" minimum Determining The Mounting P osition of The P ost Bracket Assembly Step 1 W ith the gate closed , adjust the post bracket assembly and the gate bracket until the opener is le vel.
34 Step 3 W ith the gate in the fully closed position and the opener retracted, swing the opener to the gate. Mark reference points for bolt holes on gate cross member through middle of gate bracket slots. The opener must be lev el. (Some vertical adjustment is possible by sliding the post bracket assembly up and do wn.
35 Step 3 W ith the gate in the desired open position PRESS & HOLD the “SET LIMIT" button on the control board for 5 seconds. Step 4 Press the transmitter button and allo w the gate to return to the closed position. Y OUR GA TE’S OPEN POSITION LIMIT IS NOW PR OGRAMMED.
36 A udible/Buzzer/Alarm F eedback : 1. 1 beep with 2 seconds off : Limit switch error: Limit switch’ s normally open and normally close inputs both open or both shorted. The alarm will automatically shut of f in 4 seconds after the problem is corrected.
37 2. ST A TUS LED (LED1): While the unit is IDLE : 1 blink with 2 seconds off : Free Exit terminal is shorted to common. 2 blink with 2 seconds off : Safety terminal is shorted to common. 3 blink with 2 seconds off : Edge terminal is shorted to common.
38 If your Mighty Mule ® Gate Opener is not operating properly , please follow the steps belo w: 1. First use the procedures found in the Maintenance & T roubleshooting Guide ( see page 36 ). 2. If you are unable to solve the problem, call the GT O Service Department at (800) 543-1236, or (850) 575-4144.
39 Column Installation Information I F THIS OPENER WILL BE USED WITH GA TES THA T ARE MOUNTED ON MASONR Y , BRICK, OR R OCK (etc.) COLUMNS: READ THE FOLLO WING CAREFULL Y BEFORE PR OCEEDING A. The simplest solution is to install the opener in a push-to-open configuration (requires Push-T o-Open Bracket, see Accessory Catalog).
40 Solar P anel (FM121) Not Compatible with Mighty Mule® 250 The Solar Panel is a 5 watt solar po wered battery charger for use with the FM500 & FM502 gate opener systems. Particularly suited for remote installations, each Solar P anel comes with tubular steel support, mounting clips, wire connectors, and 8 ft.
41 If you have a question about any special order item, just call 1-800-543- GA TE! Low V oltage W ire (RB509) The 16 gauge, multi-stranded, dual conductor Low V oltage W ire is for connecting the AC po wered transformer , or the Solar Panel to the control board.
デバイスGTO UL325 SERIESの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
GTO UL325 SERIESをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGTO UL325 SERIESの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。GTO UL325 SERIESの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。GTO UL325 SERIESで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
GTO UL325 SERIESを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGTO UL325 SERIESの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、GTO UL325 SERIESに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGTO UL325 SERIESデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。