HaflerメーカーIRISの使用説明書/サービス説明書
ページ先へ移動 of 19
Hafler Iris Preamplifier.
It is a good habit to turn down BOTH remote and main panel volume controls upon system shut-down. This will avoid possible sudden and unexpected changes in volume when system is re-activated. TABLE OF CONTENTS Introduction ............................
INSTALLATION The gloss black insert on the face-plate of your new Hafler Equipment has been packaged with a removable protective coating. Please peel off this protective coating following in- stallation. When cleaning the face-plate, we advise a soft cotton cloth with a non-abrasive cleaner that is safe for lexan and painted surfaces.
Power IRIS is internally connectable for virtually all AC line-power Connections systems. Units not marked otherwise, on the rear panel, are connected for 120 Vofts, 50-60 Hz. Two SWITCHED outlets and one UNSWITCHED outlet (U.S. 120 Volt standards) are provided on the rear panel.
High Level IRIS has seven pairs of main HIGH LEVEL inputs, selected by Inputs the seven (oval) KEYS to the right of the phono KEY. All of these (Oval Key inputs proceed at unity gain to the attenuator/line-amplifier selected) system, which has a maximum gain of 20dB.
OPERATION Turn-On/Off logic Muting System Volume/ Balance System CAUTION: The EPL switch and the tape MONITOR switches, explained later, are often the cause of an apparently “dead” system, when they have accidentally been left engaged. Always check them first if a system is found “dead” on turn-on.
The EPL and Tape Loop Systems The actual audio attenuation elements are passive optically- controlled resistors, arranged in a special CYBER-OPTIC control circuit (patent applications in progress) which allows a combination of very low distortion and stereo tracking accuracy (typically 0.
IRIS FUNCTIONAL BLOCK DIAGRAM (ONE CHANNEL SHOWN) MON I TOR SWITCH MON I TOR SWITCH 1 2 0 e 0 A 7 bREC 2 CUT EPL IN MAIN OUT 7.
Recording Any recording requires that you activate either the RECORD 1 System jacks, the RECORD 2 jacks (or both) using the RECORD 1 or RECORD 2 switches on the panel. As seen in the signal flow diagram, this makes any input selectable by the KEYS available to these outputs.
Tape The tape MONITOR switches at first appear to allow only a Monitoring redundant selection of what you hear from your deck(s) when Switches you use the TAPE KEY(s).
USING THE IRIS REMOTE SYSTEM Infrared Remote Integrated System INTRODUCTION Key Command Transmissions volume/ Balance (V/B) Command Transmissions The IRIS preamplifier achieves its infrared (IR) remot.
Automatic Transfer of V/B Control Note: The touching of BOTH knobs simultaneously will some- times inhibit operation of the touch-sensing system. The knob- touch system overrides any KEY-type command-so that KEY commands will not transmit, if you are accidentally touching either knob.
Remote V/B Resolution Record Security and Umbilical systems Note: Which V/B knob-set is in command is unaffected by ANY KEYS-remote or preamplifier. It depends ONLY in where the LAST V/B command came from (including the effects of pream- plifier power-up discussed earlier).
sx (Serial eXternal KEY The rear of the IRIS receiver card has a recessed, keyed male connector which carries needed digital signals for allowing the IRIS system to be connected to coming Hafler IRIS-compatible accessories, in a manner similar to which dispersed computer terminals can share the same data lines without confusion.
and pull the cover off. 2) The battery polarities are clearly marked in the plastic holder, visible when the batteries are removed. 1) Remove the 4 screws on the bottom cover of the transmitter, Carefully observing these polarity markings, replace all 4 batteries.
Even if you are experimenting, you must replace the cover before re-plugging in the unit to AC-not only for safety reasons, but to shield hum and interference which can totally invalidate any attempts at sonic evaluation.
IRIS SPECIFICATIONS Phono Section: Frequency Response: Maximum Output Voltage: Totul Harmonic Distortion & Noise Sensitivity: Signal to Noise Ratio: Maximum Input Signal: Input Impedance: Gain: LINE SECTION Frequency Response: Bandwidth: Maximum Output Voltage: (Measurements at REC OUT) 20Hz-20kHz, ±0.
Total Harmonic .005%, 20Hz-20kHz @ 2 volts RMS Distortion & Noise: Sensitivity: (For 0.5 V RMS Output): 75 mV RMS Signal to Noise -97dB (A-weighted, relative to 2.
FACTORY SERVICE AND LIMITED WARRANTY If you encounter anydifficultyor have anyquestionsconcerning your IRIS preamplifier, please call our Customer Service De- partment weekdays, 8 am to 3:30 pm Mountain Standard time, at 602-967-3565. Before returning any unit to the factory for service, please call us.
デバイスHafler IRISの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hafler IRISをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHafler IRISの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hafler IRISの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hafler IRISで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hafler IRISを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHafler IRISの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hafler IRISに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHafler IRISデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。