1 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Underwriters Laboratories Listed Models: 6000BE 6000BE-IPI In the Commonwealth of Massachusetts: • installation must be performed by a licensed plumber or gas fitter; • a CO detector shall be installed in the room where the appliance is installed.
2 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or component s MA Y BE USED .
3 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 TABLE OF CONTENTS Safety and W arning Information ................................................ 2 Service Parts Lists .........................................
4 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Part number list on following page. 5 12 6 Log Set Assembly 2 1 3 11 7 (NG , LP) Exploded Parts Diagram Service.
5 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 IT E M CO M MO N P A RTS SERI A L # P A RT NUM BER 1 S ur r o un d 2026- 1 08 2 Hood SRV60- 143- BK 3 G la s s .
6 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 (NG , LP) Exploded Parts Diagram Service Parts 6000BE-IPI IT EM DESCR I PTI O N SERI A L # P A RT NU MBER 1 V a.
7 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 (NG , LP) Exploded Parts Diagram Service Parts 6000BE IT E M DES CRI PT I O N SERI A L # P A RT NUMBER 1 B u rn.
8 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Appliance Certification The Hearth & Home T echnologies fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories.
9 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 2 Getting St arted Introducing the Hearth & Home T echnologies Gas Fireplaces Hearth & Home T echnologi.
10 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Figure 1. Diagram of the 6000BE, 6000BE-IPI 41 [1040mm ] 38 [965mm] 36 1/ 8 [916mm ] 25 1/ 4 [642mm ] 34 5/8 [.
11 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 3 Inst alling the Fireplace Step 1. Locating the Fireplace The following diagram shows space and clearance require- ments for locating a fireplace within a room.
12 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 A . ............. 42”* B . ......... 38 1/2” C . ............... 2 2 ” D . ......... 42 3/4” E . ......... 27 7/8” Figure 3. Framing Dimensions Step 2.
13 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Figure 4. DVP-Series Direct V ent Component Specifications (5-inch inner pipe / 8-inch outer pipe) NOTE: PIPES OVERLAP 1-1/4 INCHES A T EACH JOINT .
14 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Figure 5. V ent System Components and T ermination Kits Step 3. Inst alling the V ent System A. V ent System Approvals These models are approved to use DVP-series direct vent pipe components and terminations (see Figures 4 and 5).
15 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Figure 6. Straight Up V ertical V enting STRAIGHT UP VERTICAL VENTING V (FT .) 40' MAX. (12.4 M) CAP V Flue Restrictor Instructions 1. Remove Exhaust Shield using a 1/4” nut driver by removing the four screws securing it in place (see Figure 7).
16 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 HORIZONT AL VENTING Kit No. H Max. Run DV P-T RA P 24" (610 mm) Figure 1 1. Corner Inst allation NOTE: This model is tested and approved to use 45° elbows in corner installations.
17 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 V H 1' MIN. (305mm) 2' MAX. (610mm) 2' MIN. (610mm) 4' MAX. (1.22m) 3' MIN. (914mm) 6' MAX. (1.86m) 4' MIN. (1.22m) 8' MAX.
18 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Figure 14. V enting with T wo 90° Elbows VENTING WITH TWO (2) 90° ELBOWS V H H + H 1 1´ MIN. (305 mm) 2´ MAX. (610 mm) 5´ MAX. (1.52m) 2´ MIN. (610 mm) 4´ MAX.
19 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Figure 16. V enting with three 90° elbows VENTING WITH THREE (3) 90° ELBOWS 1´MIN. (305mm) 2´MAX. (610mm) 5´MAX. (1.52m) 2´MIN. (610mm) 4´MAX. (1.22m) 10´MAX.
20 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 VENTING WITH THREE (3) 90° ELBOWS V (FT .) H (FT .) 1' MIN. (305mm) 5' MAX. (1.52m) 2' MIN. (610mm) 10' MAX. (3.1m) 3' MIN. (914mm) 15' MAX.
21 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 ! B. Inst alling V ent Components After determining which set of starting collars will be used (top or rear), follow venting instructions accordingly .
22 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 3. Continue Adding V ent Component s W ARNING: INST ALLA TION OF THIS FIREPLACE REQUIRES THE USE OF HEA T SHIELD 570-290 ABOVE THE FIRST 90 0 ELBOW IN THE VENTING SYSTEM.
23 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 5. Install Firestops For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes. NOTE: Model DVP-TRAP does not need an exterior firestop on an exterior combustible wall.
24 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Figure 26. Ceiling Firestop (Ceiling Side) If the area above the ceiling IS an attic, position and secure the firestop on top of the previously framed hole. NOTE: Keep insulation away from the vent pipe at least 1 inch (25mm).
25 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 29. Minimum Clearances for T ermination A = 12 inches .................. clearances above grade, veran- da, porch, deck or balcony B = 12 inches .
26 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 For V ertical T erminations - T o locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint.
27 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Step 5. Installing the Optional Heat-Zone Kit NOTE: There must be NO INSULA TION or other com- bustibles inside the framed firestop opening. HEA T-ZONE AT TAC H E S HERE Figure 32.
28 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Figure 34. Gas Supply Line • At the gas line access hole, use insulation to re-pack the space around the gas pipe. • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing.
29 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Step 9. Wiring the Fireplace NOTE: Electrical wiring must be installed by a licensed electrician. CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS.
30 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Intermittent Pilot Ignition (IPI) Wiring 3 V olt T ransformer This appliance comes with a 3 volt transformer . The trans- former plugs into the junction box and the two leads plug into the green control module (see Figure 37).
31 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Step 10. Finishing Figure 38 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace.
32 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 ! Follow these steps: 1. Release four glass clips and set the glass assembly aside. CAUTION: The log assembly is fragile. Handle with care. NOTE: See S tep 9 when replacing the log set in an existing fireplace.
33 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 ! ! Figure 44 Figure 43 5. The grate is located in the lower cav- ity . Remove the screw holding the grate in place and discard the screw . 6. Position the grate into the cutout in the refractory .
34 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Placing the Ember Material Ember material is shipped with this gas fireplace. T o place the ember material: • Pull the four glass latches out of the groove on the glass frame.
35 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace.
36 Hearth & Home T echnologies • 6000BE, 6000BE-IPI • 2024-900 Rev . G • 1 1/05 4 Maint aining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fireplace se.
デバイスHearth and Home Technologies 6000BEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hearth and Home Technologies 6000BEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHearth and Home Technologies 6000BEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hearth and Home Technologies 6000BEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hearth and Home Technologies 6000BEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hearth and Home Technologies 6000BEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHearth and Home Technologies 6000BEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hearth and Home Technologies 6000BEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHearth and Home Technologies 6000BEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。