Herrmidifierメーカー465-C1の使用説明書/サービス説明書
ページ先へ移動 of 12
Introduction ........................................1 Specifications ......................................1 Capacity Selection Guide ..................1 Installation Physical installation ......................2 Electrical Installation .............
T ype of Unit Rotating Drum Duct Mounting Return Supply GPD @ 140 ° F 22.5 17.1 GPD @ 120 ° F 16.5 12.4 GPD @ 100 ° F 10.6 7.8 V oltage 24V Unit Dimensions 14 3/4” W x 11” D x 11 1/2” H Duct .
2 Physical Installation Remember to select a location that is readily accessible for periodic inspection and cleaning of your humidifier . This unit should be located on the cold air return side of the system for best results. However , if space does not permit, it can be mounted on the warm air supply side of the system.
3 Physical Installation Installing Humidifier 1. Remove the window panel (panel with the label) by sliding it up, pulling its bottom away from the humidifier and then pulling down. 2. Separate the top half from the pan by sliding the stainless steel retainer off the lips of the top half and pan.
4 Humidifier Humidifier Humidifier Alternate location "A" coil Air cleaner Air cleaner Air cleaner Air cleaner Bypass duct Bypass duct Bypass duct Bypass duct Humidifier Humidifier 15.
5 Electrical Installation This humidifier is intended to be wired independently of the integrated control panel on your furnace. This will provide power to the humidifier at all times, causing the evaporator pad drum to rotate constantly .
6 Operation This 465-C1 humidifier operates on the silent principle of evaporation. When your unit is operating properly , you may observe the drum turning freely by looking through the observation window .
7 Maintenance Periodic cleaning is required for the efficient and safe operation of this humidifier . Inspect the humidifier approximately once a month for mineral and algae growth. Algae may develop inside the humidifier if certain conditions exist in the water supplying the unit.
8 Maintenance 6. Lift the drum shaft out of the support and slide the drum away from the motor , then down and away from unit. 7. Dump any accumulated sludge or slime from the pan. Clean thoroughly using a 50/50 solution of white vinegar and water or liquid humidifier cleaner .
9 21 20 2 7 1 3 8 9 10 11 12 13 14 18 16 17 15 4 19 23 22 6 5 Unit Diagram.
10 Model 465 C-1 Assembly Part Number 352440-001C Item Descripton P/N Remarks 1T op 1201BP 2 Motor 1322P 24V 50/60HZ 3 Float & valve assembly 1210P 4W asher FV -17 Fiber 5 Brass Locknut FV -10 7/1.
Wa rranty Humidifier Limited T wo Y ear W arranty This limited warranty covers Herrmidifier Residential T ype Humidifiers, excluding duct work, wiring and installation. The manufacturer warrants that all new Herrmidifier Humidifiers are free from defects in material and workmanship under normal, non-commercial use and service.
デバイスHerrmidifier 465-C1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Herrmidifier 465-C1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHerrmidifier 465-C1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Herrmidifier 465-C1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Herrmidifier 465-C1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Herrmidifier 465-C1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHerrmidifier 465-C1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Herrmidifier 465-C1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHerrmidifier 465-C1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。