APOLLO 60 HP SUPPLIED-AIR RESPIRATOR CLEMCO SUPPLIED AIR RESPIRA T OR MODEL 60 HP O.M. 10533 690-0985 09/85 K, 05/15/98 MC FILE NUMBER: DATE OF ISSUE: REVISION: WARNING Do not proceed with these instructions until you have READ the orange cover of this MANU AL and Y OU UNDERST AND its content.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR x 04440 Flow Regulator x 04410 Flow Regulator x 04411 Flow Regulator x 21422 Cont. Flow Conn. x 04397 Hose 25 Ft. x 04415 Hose 50 Ft.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 2 ! W ARNING “Warning” is used to indicate a potentially haz- ardous situation which, if not avoided, could result in death or serious injury. ! DANGER “Danger” is used to indicate an imminently haz- ardous situation which, if not avoided, will result in death or serious injury.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 3 This manual does not contain all the health and safety requirements regarding toxic and hazard- ous dust exposure. Obtain copies of the OSHA regulations and consult a safety professional and/or industrial hygienist for complete require- ments.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 4 bels. (42 CFR part 84.140) When any exterior noise causes the internal noise level to exceed 80 decibels, the user must wear additional hearing protection. A variety of hearing protectors can be worn with the respirator.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 5 2.0 INSPECTION ! NOTICE A Clemco respirator hose must be used with the Apollo Respirator. If one is not available, it must be ordered from an authorized distributor of Clemco products.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 6 connect the other end of the respirator hose to a respirable air source. If longer hose is required, it must be a NIOSH- approved Clemco respirator hose extension.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 7 monoxide removal or conversion system may also be used to ensure breathing air quality. The maximum allowable presence of carbon monoxide in Grade D breathing air is 10 parts per million (ppm). 4.2 Air Volume and Pressure 4.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 8 5.1 Prior to operation, thoroughly inspect and clean the helmet, breathing tube, respirator hose, air entry ports, and fittings of all dust and debris. Inspect the helmet suspension and adjust if necessary per Section 6.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 9 6.2 Helmet Suspension Adjustment and Replacement, Figure 3 ! W ARNING The suspension maintains a fixed distance be- tween the head and the helmet. It is critical that the suspension is properly installed, and ad- justed as described, to provide maximum head protection and comfort.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 10 7.2.4 Periodically inspect and clean the foam filter and screen in the alternate air control valve. Replace the foam filter at first sign of blockage or deterioration.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Page 11 8.4.3 If the acoustical foam on the inside of the helmet becomes soiled, it can be wiped with a damp cloth or pulled off and replaced. 8.5 Inner Lens 8.5.1 Inner lenses should be replaced when dirty or scratched; however mild detergent and water can be used to clean the inner lens.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR 9.4.2 Separate the Velcro tabs on the back of the cape. See Figure 5. 9.4.3 Slide the ends of the cape to the notch. Continue sliding one end of the cape out of the groove until the entire cape is detached from the helmet.
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Figure 6. (2) (1) (3, 4, 5) (6) (7) (9) (8) (10) (11) (12) (14) (13) (15) (16) (17) (18) (24) (19) (20) (22) (23) (21) Page 13 10.2 Supplied-Air Respirator, Figure 6 Item Description Stock No. 1. Constant-flow connector, HP (alternate), without belt .
デバイスHP (Hewlett-Packard) O.M. 10533の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HP (Hewlett-Packard) O.M. 10533をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHP (Hewlett-Packard) O.M. 10533の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HP (Hewlett-Packard) O.M. 10533の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HP (Hewlett-Packard) O.M. 10533で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HP (Hewlett-Packard) O.M. 10533を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHP (Hewlett-Packard) O.M. 10533の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HP (Hewlett-Packard) O.M. 10533に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHP (Hewlett-Packard) O.M. 10533デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。